PubMed Health⌕ Search

Biomedical subjects

Rodolfo J Romañach

Publications and source records attributed to Rodolfo J Romañach.

2 recordsLinked to original sources

Quantitation of drug content in a low dosage formulation by transmission near infrared spectroscopy.

A transmission near infrared (NIR) spectroscopic method has been developed for the nondestructive determination of drug content in tablets with less than 1% weight of active ingredient per weight of formulation (m/m) drug content. Tablets were manufactured with drug concentrations of approximately 0.5%, 0.7%, and 1.0% (m/m) and ranging in drug content from 0.71 to 2.51 mg per tablet. Transmission NIR spectra were obtained for 110 tablets that constituted the training set for the calibration model developed with partial least squares regression. The reference method for the calibration model was a validated UV spectrophotometric method. Several data preprocessing methods were used to reduce the effect of scattering on the NIR spectra and base the calibration model on spectral changes related to the drug concentration changes. The final calibration model included the spectral range from 11 216 to 8662 cm(-1), the standard normal variate (SNV), and first derivative spectral pretreatments. This model was used to predict an independent set of 48 tablets with a root mean standard error of prediction (RMSEP) of 0.14 mg, and a bias of only -0.05 mg per tablet. The study showed that transmission NIR spectroscopy is a viable alternative for nondestructive testing of low drug content tablets, available for the analysis of large numbers of tablets during process development and as a tool to detect drug agglomeration and evaluate process improvement efforts.

Calibration↗

Blend uniformity analysis using stream sampling and near infrared spectroscopy.

A near infrared spectroscopic method was developed to determine drug content in a 20% (wt/wt) ibuprofen and spray-dried hydrous lactose blend. A blending profile was obtained after blending for 0.5, 1, 3, 5, 10, and 20 minutes. Stream sampling was used to collect about 20 blend samples at each of the blending times from a laboratory scale V-blender. The samples collected were used to develop a near infrared calibration model. The calibration model was then used to determine the drug content of unknown samples from 2 validation blends. The validation blends were not included in the calibration model; they were used to evaluate the effectiveness of the calibration model. A total of 45 samples from the 2 validation blends were predicted by the near infrared calibration model and then analyzed by a validated UV spectrophotometric method. The root mean square error of prediction for the first validation blend was 5.69 mg/g and 3.30 mg/g for the samples from the second blend. A paired t test at the 95% confidence level did not indicate any differences between the drug content predicted by the near infrared spectroscopy (NIRS) method and the validated UV method for the 2 blends. The results show that the NIRS method could be developed while the blending profile is generated and used to thoroughly characterize a new formulation during development by analyzing a large number of samples. The new formulation could be transferred to a manufacturing plant with an NIRS method to facilitate blend uniformity analysis.

Calibration↗