Towards optimization in digital chest radiography using Monte Carlo modelling.

A Monte Carlo based computer model of the x-ray imaging system was used to investigate how various image quality parameters of interest in chest PA radiography and the effective dose E vary with tube voltage (90-150 kV), additional copper filtration (0-0.5 mm), anti-scatter method (grid ratios 8-16 and air gap lengths 20-40 cm) and patient thickness (20-28 cm) in a computed radiography (CR) system. Calculated quantities were normalized to a fixed value of air kerma (5.0 microGy) at the automatic exposure control chambers. Soft-tissue nodules were positioned at different locations in the anatomy and calcifications in the apical region. The signal-to-noise ratio, SNR, of the nodules and the nodule contrast relative to the contrast of bone (C/C(B)) as well as relative to the dynamic range in the image (C(rel)) were used as image quality measures. In all anatomical regions, except in the densest regions in the thickest patients, the air gap technique provides higher SNR and contrast ratios than the grid technique and at a lower effective dose E. Choice of tube voltage depends on whether quantum noise (SNR) or the contrast ratios are most relevant for the diagnostic task. SNR increases with decreasing tube voltage while C/C(B) increases with increasing tube voltage.

Humans↗

Evaluation of a novel method of noise reduction using computer-simulated mammograms.

A novel method of noise reduction has been tested for mammography using computer-simulated images for which the truth is known exactly. This method is based on comparing two images. The images are compared at different scales, using a cross-correlation function as a measure of similarity to define the image modifications in the wavelet domain. The computer-simulated images were calculated for noise-free primary radiation using a quasi-realistic voxel phantom. Two images corresponding to slightly different geometry were produced. Gaussian noise was added with certain properties to simulate quantum noise. The added noise could be reduced by >70% using the proposed method without any noticeable corruption of the structures. It is possible to save 50% dose in mammography by producing two images (each 25% of the dose for a standard mammogram). Additionally, a reduction of the anatomical noise and, therefore, better detection rates of breast cancer in mammography are possible.

Artifacts↗