A modified projection reconstruction trajectory for reduction of undersampling artifacts.

PURPOSE: To reduce undersampling artifacts for a given number of repetitions of the projection reconstruction (PR) sequence by modifying its k-space trajectory to sample more mid-frequencies while reducing the sampling coverage of the peripheral spatial frequencies. MATERIALS AND METHODS: The single k-space spoke measured per repetition in the standard PR was modified so that one complete and two partial spokes were measured per repetition but with decreased k-space extent. The point spread functions (PSFs) and undersampling artifacts of the modified PR were compared with those of the standard PR for various numbers of projections. Phantom and in vivo images were used to assess the relative performance. RESULTS: PSF analysis indicated that the modified PR method provided reduced undersampling artifacts with somewhat reduced spatial resolution. The phantom and in vivo images corroborated this. CONCLUSION: The modified PR trajectory provides reduced undersampling artifact vs. the standard PR, particularly when the number of projections is limited and the artifact level is high.

Artifacts↗

Interscan registration using navigator echoes.

A common problem in clinical MRI is anatomic misalignment of imaging slices across successive examinations. This unnecessarily complicates the radiologic assessment of anatomic change over time on serial MRI studies. To address this problem, spherical navigator echoes, which can detect rigid body motion in all six degrees of freedom, were used to guide spatial location and orientation adjustments to an exam prescription to match the reference frame of images acquired in an earlier exam. An initial linear navigator echo is also necessary to effect coarse Z translation adjustments prior to fine six degrees of freedom adjustment with a spherical navigator echo. Results of this technique are presented for head image volumes of five volunteers. Each volunteer was imaged on two scanners. In all cases, the reference frame adjustments provided by the navigator echoes substantially improved the alignment of the latter exam and performed well compared to retrospective image-based registration.

Algorithms↗

On the feasibility of elastic wave visualization within polymeric solids using magnetic resonance elastography.

In this paper, the feasibility of extending previously described magnetic resonance elastography (MRE) dynamic displacement (and associated elasticity) measurement techniques, currently used successfully in tissue, to solid materials which have much higher shear rigidity and much lower nuclear spin densities, is considered. Based on these considerations, the MRE technique is modified in a straightforward manner and used to directly visualize shear wave displacements within two polymeric materials, one of which is relatively stiff.

Algorithms↗

Spherical navigator echoes for full 3D rigid body motion measurement in MRI.

We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k-space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k-space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least-squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k-space sampling strategies on such a shell. Data collected with a computer-controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time-intensive sampling method. This number of samples can be captured in an approximately 27-ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes.

Humans↗

Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI.

A method is presented in which an extended longitudinal field of view (FOV), as required for whole-body MRI or MRA peripheral runoff studies, is acquired in one seamless image. Previous methods typically either acquired 3D data at multiple static "stations" which covered the extended FOV or as a series of 2D axial sections. The method presented here maintains the benefits of 3D acquisition while removing the discrete nature of the multistation method by continuous acquisition of MR data as the patient table moves through the desired FOV. Although the technique acquires data only from a homogeneous central volume of the magnet at any point in time, by spatially registering all data it is possible to extend the FOV well beyond this volume. The method is demonstrated experimentally with phantoms, in vivo angiographic animal studies, and in vivo human studies.

Animals↗