In a standard insertion device, such as a wiggler or undulator, the force between two rows of magnets increases exponentially as the gap between the rows decreases. This force is usually managed by a powerful mechanical gap adjustor, sometimes with the aid of springs at small values of gap. This paper is a description of how the magnetic forces can be nulled using auxiliary counterforce magnets.