A procedure for calibration transfer between near-infrared instruments--a worked example using a transmittance single tablet assay for piroxicam in intact tablets.

A procedure was developed for different modes of calibration transfer in near-infrared (NIR) spectroscopy, which included a method for the selection of a subset of samples appropriate for transfer. As a worked example, these guidelines were applied to the transfer of a multivariate calibration model, representing a validated NIR single tablet assay for the active within an intact pharmaceutical product, between three equivalent dispersive NIR transmission instruments. Transfer was first evaluated between two instruments, representing the situation where both were available during calibration development. A spectral correction method alone, applied to the transfer instrument, was not sufficient to facilitate transfer, with further optimisation of the calibration model using a novel wavelength selection algorithm necessary to remove regions of the spectral range that resulted in skewed predictions on the second instrument. Through this approach, a single calibration model was found to be equally accurate and precise on the two instruments. A procedure, using the Kennard-Stone algorithm, is described for determining a reduced number of samples as a transfer set using only the spectral information from the original instrument. The purpose of the subset was to permit transfer to a new instrument where that instrument was not available until after calibration development or where it was undesirable to re-measure the full sample set (i.e. due to excessive reference chemistry). Utilising the transfer set, transfer to a third instrument was evaluated. The calibration model, optimised between the first two instruments, was not directly applicable for the third instrument, with further wavelength selection required to remove a small region of spectral data. On completion, using a full statistical evaluation, a single calibration model was found to be equally accurate and precise on all three instruments.

Anti-Inflammatory Agents, Non-Steroidal↗

Application of near-infrared spectroscopy to the determination of the sites of manufacture of proprietary products.

Reflectance near-infrared (NIR) spectroscopy has been investigated as a method to distinguish between the sites of manufacture of a number of proprietary tablets. As test samples, parallel imports which are pharmaceutically equivalent products manufactured at different sites have been used. Three products: Aremis/Besitran, Renitec and Voltarol Retard originating from two or more sites and Adalat from a single site were examined. The principal component analysis (PCA) score plots showed that spectra of tablets originating from different sites of manufacture often gave rise to statistically different populations. PCA loadings indicated that the differences were related to moisture content and excipients. Spectra were used to construct a library for the classification of tablets to predict the site of manufacture based on the method of residual variance of the principal components. Where a large data set was available (Aremis/Besitran tablets) prediction rates for the successful identification of the two sites of manufacture, Madrid and Barcelona, were 95.7 and 98.1%, respectively for the validation set with all errors encountered of Type I.

Drug Industry↗

Feasibility study for the rapid determination of the amylose content in starch by near-infrared spectroscopy.

Near-infrared (NIR) spectroscopy was used to determine the amylose content in six different starches, whose declared amylose contents ranged from 2 to 95% m/m. The amylose content of starches can vary considerably between batches depending on growth conditions and time of harvesting. An NIR calibration model was developed for amylose using simple laboratory produced mixtures of amylose and amylopectin in different ratios. The spectral region at 1700-1800nm showed a good correlation to the amylose content of these mixtures. A simple absorbance ratio calibration model using standard normal variate and first derivative pre-treated spectra gave a root mean standard error of prediction of 1.2% m/m. Application to real samples gave amylose contents in reasonable agreement with the average values stated by the supplier. NIR spectroscopy provides a rapid and non-destructive method for the quantitative determination and standardisation of amylose in starch and could make a suitable alternative to traditional techniques, such as complex formation of starch with iodine or n-butanol.

1-Butanol↗

Measurement of the percentage volume particle size distribution of powdered microcrystalline cellulose using reflectance near-infrared spectroscopy.

This is the first reported method for determining the percentage volume particle size distribution of a powder (microcrystalline cellulose) by near-infrared (NIR) reflectance spectroscopy. A total of 113 samples of powdered microcrystalline cellulose were used from six different commercially available grades, with different moisture contents (range: 0.9-4.8% m/m). NIR reflectance measurements of these samples were made in narrow soda glass vials. Reference particle size data for the samples were acquired by laser diffraction. The NIR data were then calibrated to measure particle size by partial least squares regression. The effects of a range of different NIR data pre-treatments on calibration and prediction precision were investigated. Overall, simple absorbance data were found to produce regression models with the best predictive ability (root mean square error of prediction = 0.90%). The method was also found to be insensitive to moisture content.

Cellulose↗

Optimisation of partial least squares regression calibration models in near-infrared spectroscopy: a novel algorithm for wavelength selection.

A novel optimisation algorithm is presented for full spectrum calibration models in near-infrared (NIR) spectroscopy. The algorithm is used to investigate the affect of removing continuous spectral regions on parameters critical to the validity of the model (e.g. explained variance, bias etc.) and ultimately identify and remove problem areas of the spectrum. As an example of its application, this paper shows how to optimise partial least squares regression (PLSR) calibration models for predicting moisture content within an intact pharmaceutical product and how problems due to changes in the nature of samples since setting up the original model may be eliminated. On application of two validated calibration models to a new set of samples unacceptable results were obtained for bias (-0.26 and -0.21% m/m moisture content) between the NIR predicted values and the true values (Karl Fischer analysis). The optimisation algorithm identified small regions of the spectrum, which if included in development of the models contributed significant bias to the final prediction. On removal of these problem regions the calibration models were found to be equally accurate and precise, but with the added advantage of robustness to a variable region of the sample spectrum (bias reduced to -0.05 and -0.09% m/m).

Calibration↗

The transfer between instruments of a reflectance near-infrared assay for paracetamol in intact tablets.

This study compares several correction methods to facilitate the transfer of a validated near-infrared (NIR) assay for paracetamol in intact tablets between two reflectance NIR instruments of the same type. Transfer was defined as the ability to accurately predict the true assay value of a sample measured on a NIR system using an assay developed on a different system, and was assessed using a comprehensive set of statistical tests. Direct electronic transfer of the calibration models, representing the NIR assay, was not possible as a result of a definite residual spectrum between instruments. The use of a correction method based on the standardisation of the material used to record the reference spectrum also proved ineffective. Two methods investigated did succeed, the first employed a response surface calculated between the reflectance values of a set of six certified photometric standards measured on both instruments, with all full range partial least square (PLS) regression models subsequently transferred. The next was correction of the spectra from the second instrument utilising the residual spectrum between the mean sample of the validation set measured on both instruments. Through this approach all PLS regression models and also a single multiple linear regression (MLR) model were transferred. As an outcome of this study guidelines are suggested for the transfer of NIR assays along with the criteria deemed necessary to conclusively prove transfer and justify any correction method utilised. The significant criteria were determined to be the paired t-test with both the UV reference assay data and the original NIR assay data, and comparison of the coefficient of multiple determinations.

Acetaminophen↗