PubMed Health⌕ Search

Biomedical subjects

Roger D White

Publications and source records attributed to Roger D White.

39 records · Page 3Linked to original sources

New concepts in transthoracic defibrillation.

The transition of biphasic waveforms from ICDs to external defibrillators constitutes a significant technological advances for transthoracic defibrillation. Impedance compensation has enabled the delivery of defibrillating current adapted to each patient and each shock in the same patient. Optimally designed biphasic waveforms have been shown clinically to have greater efficacy in the termination of VF when compared with monophasic waveforms, and because peak current delivery is less, these waveforms are likely to be less injurious to myocardial function. Advances in the understanding of the mechanisms of fibrillation and defibrillation have identified the electrophysiologic events that initiate and sustain VF and the effects of defibrillation shocks on those events. Definition of the role of VEP and postshock excitation has clarified the mechanisms by which shocks can either fail or succeed. The ability of the second phase of optimal biphasic waveform shocks to exploit recruited sodium channels in negatively polarized areas and thus induce rapid propagation of postshock excitation assures uniform depolarization and prevention of re-entry. This appears to be the major mechanism of greater efficacy of biphasic waveforms. It seems certain that continuing investigation of virtual electrodes will enhance our understanding of defibrillation and optimal waveforms. At the same time, much more needs to be known regarding translation of these experimental observations to mechanisms of defibrillation in human hearts with long-standing underlying structural heart disease, which often arises of multiple factors. This represents a major challenge in defibrillation research.

Animals↗

Law Enforcement Agency Defibrillation (LEA-D): proceedings of the National Center for Early Defibrillation Police AED Issues Forum.

Why does LEA-D intervention seem to work in some systems but not others? Panelists agreed that some factors that delay rapid access to treatment, such as long travel distances in rural areas, may represent insurmountable barriers. Other factors, however, may be addressed more readily. These include: absence of a medical response culture, discomfort with the role of medical intervention, insecurity with the use of medical devices, a lack of proactive medical direction, infrequent refresher training, and dependence on EMS intervention. Panelists agreed that successful LEA-D programs possess ten key attributes (Table 6). In the end, the goal remains "early" defibrillation, not "police" defibrillation. It does not matter whether the rescuer wears a blue uniform--or any uniform, for that matter--so long as the defibrillator reaches the victim quickly. If LEA personnel routinely arrive at medical emergencies after other emergency responders or after 8 minutes have elapsed from the time of collapse, an LEA-D program will be unlikely to provide added value. Similarly, if police frequently arrive first, but the department is unwilling or unable to cultivate the attributes of successful LEA-D programs, efforts to improve survival may not be realized. In most communities, however, LEA-D programs have tremendous lifesaving potential and are well worth the investment of time and resources. Law enforcement agencies considering adoption of AED programs should review the frequency with which police arrive first at medical emergencies and LEA response intervals to determine whether AED programs might help improve survival in their communities. It is time for law enforcement agency defibrillation to become the rule, not the exception.

Cardiopulmonary Resuscitation↗