Vacuum-assisted apical suction devices induce passive electrical changes consistent with myocardial ischemia during off-pump coronary artery bypass graft surgery.

OBJECTIVE: Off-pump coronary artery bypass graft surgery is common therapy to completely revascularize diseased hearts. In order to graft posterior arteries in this procedure, the heart must be lifted from the chest cavity and manipulated to expose the surgical field using an apical suction device. This suction device may cause unwanted myocardial ischemia. METHODS: In this observational study, we measured myocardial electrical impedance, a parameter that responds to myocardial ischemia, as well as ST-segment changes during off-pump coronary artery bypass graft surgery in 12 patients with two-vessel coronary artery disease undergoing revascularisation of the left anterior descending and the posterior descending coronary arteries. During the posterior descending artery revascularisation phase of the procedure the apical suction device was oriented over the electrodes used to measure myocardial electrical impedance, thus allowing us the opportunity to assess myocardial ischemia in this region of the heart. RESULTS: In these 12 patients, myocardial electrical impedance progressively increased under the suction device during posterior coronary artery revascularisation, suggesting that myocardial ischemia developed in this region of the myocardium. ST-segment changes were negligible while the heart was vertically displaced (and the suction device attached), but increased immediately when the heart was returned to the neutral anatomical position. CONCLUSION: Our data suggest that the apical suction device may cause ischemia while the heart is vertically displaced and electrically disconnected from the body. Under these conditions, ST-segment changes may not detect myocardial ischemia. Myocardial electrical impedance has the potential to reliably detect intraoperative myocardial ischemia under these circumstances.

Coronary Artery Bypass, Off-Pump↗

Early time course of myocardial electrical impedance during acute coronary artery occlusion in pigs, dogs, and humans.

Changes in myocardial electrical impedance (MEI) and physiological end points have been correlated during acute ischemia. However, the importance of MEI's early time course is not clear. This study evaluates such significance, by comparing the temporal behavior of MEI during acute total occlusion of the left anterior descending coronary artery in anesthetized humans, dogs, and pigs. Here, interspecies differences in three MEI parameters (baseline, time to plateau onset, and plateau value normalized by baseline) were evaluated using Kruskal-Wallis ANOVA and post hoc tests (P < 0.05). Noteworthy differences in the MEI time to plateau onset were observed: In dogs, MEI ischemic plateau was reached after 46.3 min (SD 12.9) min of occlusion, a significantly longer period compared with that of pigs and humans [4.7 (SD 1.2) and 4.1 min (SD 1.9), respectively]. However, no differences could be observed between both animal species regarding the normalized MEI ischemic plateau value (15.3% (SD 4.7) in pigs, vs. 19.6% (SD 2.6) in dogs). For all studied MEI parameters, only swine values resembled those of humans. The severity of myocardial supply ischemia, resulting from coronary artery occlusion, is known to be dependent on collateral flow. Thus, because dogs possess a well-developed collateral system (unlike humans or pigs), they have shown superior resistance to occlusion of a coronary artery. Here, the early MEI time course after left anterior descending coronary artery occlusion, represented by the time required to reach ischemic plateau, was proven to reflect such interspecies differences.

Acute Disease↗

Myocardial electrical impedance responds to ischemia and reperfusion in humans.

Myocardial electrical impedance (MEI) is correlated to ischemia and reperfusion of the heart muscle. The entire body of work with MEI to this point has been carried out in animal subjects in vivo and excised tissue samples. In this study, we measured MEI clinically for the first time in human patients who were undergoing off-pump coronary artery bypass (OPCAB) surgery. MEI was measured with a monitor designed in this laboratory and approved by the FDA for use on human subjects. Our patient population (n = 18) had a 70%-100% stenosis of the diseased coronary artery targeted for bypass. We measured MEI continuously during surgery and at 3, 6, 24, and 72 h postoperatively from two temporary pacing electrodes attached to the heart muscle. Absolute baseline impedance ranged from 173 to 729 ohms. MEI increased with occlusion of the diseased artery prior to bypass. The percent increase from baseline was inversely correlated to the percent stenosis of the diseased artery. MEI decreased below baseline immediately on reperfusion following bypass in all patients and continued decreasing over the measurement period. MEI is a reliable clinical indicator of ischemia and reperfusion in humans and may indicate the effectiveness of coronary artery surgery. The parameter may have monitoring and diagnostic value in heart disease in humans.

Adult↗