Defining the role of endovascular therapy in the treatment of abdominal aortic aneurysm: results of a prospective randomized trial.

Following publication of early registry data showing poor durability for first-generation endografts, EVAR was labeled by some as a failed experiment. The EVAR trial results prove such a pessimistic appraisal of EVAR wrong. In patients fit for open AAA repair EVAR w ith current devicesachieves a 3% benefit in operative and 4-year aneurysm-related mortality compared with open surgery. In patients unfit for open repair 30-day mortality is significantly greater and can no longer be described as safe. Nor does EVAR affect aneurysm-related or all-cause mortality in the 4-year follow-up. EVAR, at least for the first 4 years, is not safe or effective. Based on these results it seems appropriate in unfit patients to attend to concurrent medical problems before considering intervention for an asymptomatic aneurysm. Before the publication of this trial it was generally believed that EVAR would be of benefit in such patients; indeed, it was for the high-risk patient that EVAR was originally conceived. The focus changes from urgency to deploy EVAR to improvement of fitness, recognizing that such patients are very sick with multiple comorbidities. In both fit and unfit patients with large aneurysms most late deaths were cardiovascular related. The importance of risk factor management in both patient groups cannot be overstated. Despite the cost implications of EVAR and its failure to improve mid-term all-cause mortality over open AAA repair it is likely that the bias of both patients and surgeons toward this minimally invasive procedure means that it will continue to have a significant role. Experience and endograft developments have the potential to reduce postoperative complications; surveillance strategies could then be amended to reduce cost implications. Alternatively, over time the currently static rate of complications may increase as endografts reach the end of their working life. The long-term follow-up of patients in both the both EVAR Trials 1 and 2 has the potential for future surprises.

Aneurysm, Ruptured↗

Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review.

PURPOSE: To synthesize the available evidence regarding the diagnostic accuracy of color duplex ultrasonography (CDU) versus the accepted gold-standard of contrast-enhanced computed tomography (CT) for the detection and classification of endoleaks after aortic endografting. METHODS: A systematic search of the literature was conducted using electronic bibliographical databases and other means to gather articles published between 1991 and 2004. Articles were scrutinized against inclusion/exclusion criteria that broadly followed the QUADAS quality assessment guidelines. The results of diagnostic CDU were expressed for each study as a 2x2 contingency table, and summary statistics (sensitivity/specificity with 95% confidence intervals [CI]) were calculated. Pooled and random effects meta-analyses were performed. RESULTS: Eight published studies and 2 unpublished studies from Charing Cross and St. George's Hospitals (711 patients, 1355 paired scans performed > or = 1 month after endografting) were eligible for inclusion. From meta-analyses, the pooled sensitivity of CDU (versus CT as the gold standard) was 69% (95% CI 52% to 87%) and the specificity of CDU was 91% (95% CI 87% to 95%). These parameters did not appear to vary over time when a smaller dataset of 117 patients with 239 paired scans was used to compare CT and CDU specifically at 3, 12, and 24 months after endografting. Endoleak classification data, which was derived from only 5 small studies, indicated that CDU appeared to have better diagnostic accuracy in detecting type I or type III endoleaks compared with type II endoleaks; however, the data were insufficient for statistical analysis. CONCLUSIONS: CDU currently does not have sufficient diagnostic accuracy for the detection of all endoleaks in routine clinical practice. The diagnostic accuracy of CDU may improve if type II endoleaks are ignored.

Angioscopy↗

Abdominal aortic aneurysm expansion: risk factors and time intervals for surveillance.

BACKGROUND: Intervention to reduce abdominal aortic aneurysm (AAA) expansion and optimization of screening intervals would improve current surveillance programs. The aim of this study was to characterize AAA growth in a national cohort of patients with AAA both overall and by cardiovascular risk factors. METHODS AND RESULTS: In this study, 1743 patients were monitored for changes in AAA diameter by ultrasonography over a mean follow-up of 1.9 years. Mean initial AAA diameter and growth rate were 43 mm (range 28 to 85 mm) and 2.6 mm/year (95% range, -1.0 to 6.1 mm/year), respectively. Baseline diameter was strongly associated with growth, suggesting that AAA growth accelerates as the aneurysm enlarges. AAA growth rate was lower in those with low ankle/brachial pressure index and diabetes but higher for current smokers (all P<0.001). No other factor (including lipids and blood pressure) was associated with AAA growth. Intervals of 36, 24, 12, and 3 months for aneurysms of 35, 40, 45, and 50 mm, respectively, would restrict the probability of breaching the 55-mm limit at rescreening to below 1%. CONCLUSIONS: Annual, or less frequent, surveillance intervals are safe for all AAAs < or =45 mm in diameter. Smoking increases AAA growth, but atherosclerosis plays a minor role.

Aged↗

The intermittent claudication questionnaire: a patient-assessed condition-specific health outcome measure.

INTRODUCTION: As yet, there is no patient-assessed, condition-specific instrument for the assessment of health-related quality of life in intermittent claudication. We evaluated the intermittent claudication questionnaire (ICQ) for properties required of a measure of health outcome. METHODS AND RESULTS: Interviews with patients with intermittent claudication and vascular specialist opinion produced a pool of statements used to itemize a self-completed ICQ. This was piloted in 20 patients for practicality and then administered to 124 stable claudicants. Reliability was assessed through a retest in 63 (51%) patients at 14 days and analysis of Cronbach's alpha for internal consistency. Spearman's correlation coefficient was used to assess construct validity in comparisons between the ICQ and ankle brachial pressure index, treadmill-walking distances, the walking impairment questionnaire, the EuroQol, and the Short Form-36. Responsiveness of the ICQ to changes in health was assessed in 60 patients treated conservatively and 40 patients undergoing angioplasty. The standardized response mean was used to identify the most responsive instrument in the study. A 16-item ICQ with a test-retest intraclass correlation of 0.95 and Cronbach's alpha of.94 was produced. One hundred twenty-one (98%) patients completed the ICQ (mean time, 3.7 minutes). The ICQ correlated better with the EuroQol (r = 0.58) and 7 out of 8 subscales of the Short Form-36 (r = 0.33-0.68) compared with the walking impairment questionnaire. The ICQ demonstrated the largest standardized response mean in relation to health transition compared with the other instruments. CONCLUSIONS: The patient-assessed ICQ is a practical, reliable, valid, and responsive measure of patient health-related quality of life in intermittent claudication.