PubMed Health⌕ Search

Biomedical subjects

Roger N Greenwood

Publications and source records attributed to Roger N Greenwood.

10 recordsLinked to original sources

International differences in dialysis mortality reflect background general population atherosclerotic cardiovascular mortality.

Existing national, racial, and ethnic differences in dialysis patient mortality rates largely are unexplained. This study aimed to test the hypothesis that mortality rates related to atherosclerotic cardiovascular disease (ASCVD) in dialysis populations (DP) and in the background general populations (GP) are correlated. In a cross-sectional, multinational study, all-cause and ASCVD mortality rates were compared between GP and DP using the most recent data from the World Health Organization mortality database (67 countries; 1,571,852,000 population) and from national renal registries (26 countries; 623,900 population). Across GP of 67 countries (14,082,146 deaths), all-cause mortality rates (median 8.88 per 1000 population; range 1.93 to 15.40) were strongly related to ASCVD mortality rates (median 3.21; range 0.53 to 8.69), with Eastern European countries clustering in the upper and Southeast and East Asian countries in the lower rate ranges. Across DP (103,432 deaths), mortality rates from all causes (median 166.20; range 54.47 to 268.80) and from ASCVD (median 63.39 per 1000 population; range 21.52 to 162.40) were higher and strongly correlated. ASCVD mortality rates in DP and in the GP were significantly correlated; the relationship became even stronger after adjustment for age (R(2) = 0.56, P < 0.0001). A substantial portion of the variability in mortality rates that were observed across DP worldwide is attributable to the variability in background ASCVD mortality rates in the respective GP. Genetic and environmental factors may underlie these differences.

Atherosclerosis↗

Large variations in prescriptions of gastrointestinal medications in hemodialysis patients on three continents: the Dialysis Outcomes and Practice Patterns Study (DOPPS).

Little is known about proton pump inhibitor (PPI) or H(2) receptor antagonist (HA) prescription patterns or regarding use of predictors in hemodialysis patients. Proton pump inhibitor and HA prescribing patterns were investigated in 8628 hemodialysis patients from seven countries enrolled in the prospective, observational Dialysis Outcomes and Practice Patterns Study. Logistic regression examined predictors associated with PPI and HA use, adjusting for age, sex, country, time with end-stage renal disease, medications, 14 comorbid conditions, and the association between the number of comorbid conditions and the prescription of gastrointestinal (GI) medications. In a cross-section from February 1, 2000, 3.4% to 36.9% of patients received an HA and 0.8% to 26.9% took a PPI, depending upon the country. From 1996 to 2001, the prescription of HAs declined while PPI use increased. Facility use of HAs and PPIs ranged from 0% to 94% of patients. H2 receptor antagonist or PPI use was significantly and independently associated with age, narcotic use, corticosteroids, acetaminophen, nonsteroidal anti-inflammatory drugs, tricyclic antidepressants, selective serotonin reuptake inhibitors, coronary artery disease history, cardiovascular diseases other than hypertension or congestive heart failure, peripheral vascular disease, pulmonary disease, and GI bleed. Proton pump inhibitors or HAs were more likely to be prescribed in Italy, Spain, and the United Kingdom than in the United States. The odds of PPI prescription increased if serum phosphorus <5.5 mEq/L or serum albumin <3.5 g/dL. Prescription of GI medications was associated with many comorbidities and use of several medications. Extreme variability of prescription patterns suggests that there is no standard approach in treatment practices.

Adult↗

Effect of ultrafiltration on thermal variables, skin temperature, skin blood flow, and energy expenditure during ultrapure hemodialysis.

The cause of the increase in core temperature (CT) during hemodialysis (HD) is still under debate. It has been suggested that peripheral vasoconstriction as a result of hypovolemia, leading to a reduced dissipation of heat from the skin, is the main cause of this increase in CT. If so, then it would be expected that extracorporeal heat flow (Jex) needed to maintain a stable CT (isothermic; T-control = 0, no change in CT) is largely different between body temperature control HD combined with ultrafiltration (UF) and body temperature control HD without UF (isovolemic). Consequently, significant differences in DeltaCT would be expected between isovolemic HD and HD combined with UF at zero Jex (thermoneutral; E-control = 0, no supply or removal of thermal energy to and from the extracorporeal circulation). During the latter treatment, the CT is expected to increase. In this study, changes in thermal variables (CT and Jex), skin blood flow, energy expenditure, and cytokines (TNF-alpha, IL-1 receptor antagonist, and IL-6) were compared in 13 patients, each undergoing body temperature control (T-control = 0) HD without and with UF and energy-neutral (E-control = 0) HD without and with UF. CT increased equally during energy-neutral treatments, with (0.32 +/- 0.16 degrees C; P = 0.000) and without (0.27 +/- 0.29 degrees C; P = 0.006) UF. In body temperature control treatments, the relationship between Jex and UF tended to be significant (r = -0.51; P = 0.07); however, there was no significant difference in cooling requirements regardless of whether treatments were done without (-17.9 +/- 9.3W) or with UF (-17.8 +/- 13.27W). Changes in energy expenditure did not differ among the four treatment modes. There were no significant differences in pre- and postdialysis levels of cytokines within or between treatments. Although fluid removal has an effect on thermal variables, no single mechanism seems to be responsible for the increased heat accumulation during HD.

Body Temperature↗

Selected lessons learned from the Dialysis Outcomes and Practice Patterns Study (DOPPS).

The Dialysis Outcomes and Practice Patterns Study (DOPPS) is a prospective, observational study of the relationships between hemodialysis (HD) patient outcomes and HD treatment practices. The DOPPS began in 1996 in the United States, expanding to France, Germany, Italy, Japan, Spain, and the United Kingdom in 1998-1999, and then to Australia, Belgium, Canada, New Zealand, and Sweden in 2002. More than 300 dialysis units have participated in the DOPPS since 1996, with mortality data collected from nearly 90,000HD patients and detailed longitudinal data from nearly 30,000 HD patients. Large sample size and the large treatment practice variation observed in the DOPPS--given its international scope of participation--provide strong statistical power to investigate many different HD practices. Furthermore, the detailed patient data collected in the DOPPS allow relationships to account for differences in a large number of patient characteristics. More than 55 papers have been published from the DOPPS; here we provide a summary of selected DOPPS findings regarding nutrition, mineral metabolism, anemia management, vascular access, depression, and use of multivitamins and statins.

Anemia↗

Patterns of hepatitis C prevalence and seroconversion in hemodialysis units from three continents: the DOPPS.

BACKGROUND: Hepatitis C virus (HCV) remains a problem within hemodialysis units. This study measures HCV prevalence and seroconversion rates across seven countries and investigates associations with facility-level practice patterns. METHODS: The study sample was from the Dialysis Outcomes and Practice Patterns Study (DOPPS), a prospective, observational study of adult hemodialysis patients randomly selected from 308 representative dialysis facilities in France, Germany, Italy, Japan, Spain, the United Kingdom, and the United States. Logistic regression was used to model odds of HCV prevalence, and Cox regression was used to model time from study entry to HCV seroconversion. RESULTS: Mean HCV facility prevalence was 13.5% and varied among countries from 2.6% to 22.9%. Increased HCV prevalence was associated with longer time on dialysis, male gender, black race, diabetes, hepatitis B (HBV) infection, prior renal transplant, and alcohol or substance abuse in the previous 12 months. Approximately half of the facilities (55.6%) had no seroconversions during the study period. HCV seroconversion was associated with longer time on dialysis, human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS), HBV infection, and recurrent cellulitis or gangrene. An increase in highly trained staff was associated with lower HCV prevalence (OR = 0.93 per 10% increase, P= 0.003) and risk of seroconversion (RR = 0.92, P= 0.07). Seroconversion was associated with an increase in facility HCV prevalence (RR = 1.36, P < 0.0001), but not with isolation of HCV-infected patients (RR = 1.01, P= 0.99). CONCLUSION: There are differences in HCV prevalence and rate of seroconversion at the country and the hemodialysis facility level. The observed variation suggests opportunities for improved HCV outcomes.

Aged↗

Erythropoeitin dose variation in different facilities in different countries and its relationship to drug resistance.

BACKGROUND: The correction of anemia using erythropoeitin (EPO) is accorded high priority in the management of patients undergoing hemodialysis (HD). Target hemoglobin (Hb) levels have been established in many countries. Following an observation that the mean facility EPO dose in a chain of facilities in the United States varied by more than two-fold, an examination of the practice of anemia correction in other settings was carried out. METHODS: We reviewed demographic and laboratory parameters in prevalent HD patients in 50 United States facilities and in a single HD facility in Vicenza, Italy. The mean EPO dose profile of the United States facilities was compared with the profiles in 10 facilities in the eastern United Kingdom (UKER) and in 20 facilities reporting to the United Kingdom Renal Registry (UKRR). Analysis of the factors that correlate with EPO resistance was carried out using the United States and Italian data. RESULTS: The average EPO doses, by facility, in the 51 United States, the 10 UKER, and the 19 UKRR facilities were 19,569, 8,416, and 7,992 international units per week (IU/wk), respectively. While examination of the UKRR revealed a similar degree of inter-facility variation (2.6-fold), much larger doses of EPO were being administered in the United States patients, particularly in the low Hb group. Multivariate analysis of the United States data suggested that factors related to inflammation, including low albumin, the use of tunneled catheters for vascular access, and low protein catabolic rate (enPCR) correlated with low Hb and relative EPO resistance. CONCLUSION: Despite similar guidelines for anemia management, significant differences in practice are observed. While there seems to be a reluctance to administer large EPO doses to individual patients in Europe, this does not seem to apply in the United States, where more EPO is given. EPO resistance seems relative rather than absolute in many patients, allowing some to respond to the higher doses.

Aged↗

Identical decline of residual renal function in high-flux biocompatible hemodialysis and CAPD.

BACKGROUND: Patients on conventional hemodialysis lose residual renal function more rapidly than patients on continuous ambulatory peritoneal dialysis (CAPD). The effect of dialysis using synthetic membranes and ultrapure water is less clear. METHODS: The decline of urea clearance was compared in a cohort of 475 incident end-stage renal failure patients who received treatment with CAPD (N=175) or hemodialysis (HD) utilizing high-flux polysulphone membranes, ultrapure water, and bicarbonate as the buffer (N=300). RESULTS: CAPD patients were significantly younger, fitter (lower comorbidity severity score), less dependent (higher Karnofsky performance score) and less likely to have presented late than HD patients. There was no difference in the mean urea clearance in each group at dialysis initiation, or at any 6-month time point during the ensuing 48 months. This was true even after exclusion of patients who had died in the first year after initiation, those transferred to another dialysis modality, or those who had been transplanted. Only age and chronic interstitial disease predicted retention of urea clearance at one year. The rate of decline of urea clearance was similar in pre- and post-dialysis initiation phases, though there may have been a step-decline of about 2 mL/min at initiation, which requires further investigation. CONCLUSIONS: In hemodialysis using high-flux biocompatible membranes and ultrapure water, residual renal function declines at a rate indistinguishable from that in CAPD. This may have important implications, since preservation of residual renal function has major benefits and is a valid therapeutic goal.

Adult↗

Vascular access use in Europe and the United States: results from the DOPPS.

BACKGROUND: A direct broad-based comparison of vascular access use and survival in Europe (EUR) and the United States (US) has not been performed previously. Case series reports suggest that vascular access practices differ substantially in the US and EUR. We report on a representative study (DOPPS) which has used the same data collection protocol for> 6400 hemodialysis (HD) patients to compare vascular access use at 145 US dialysis units and 101 units in five EUR countries (France, Germany, Italy, Spain, and the United Kingdom). METHODS: Logistic analysis evaluated factors associated with native arteriovenous fistula (AVF) versus graft use or permanent access versus catheter use for prevalent and incident HD patients. Times to failure for AVF and graft were analyzed using Cox proportional hazards regression. RESULTS: AVF was used by 80% of EUR and 24% of US prevalent patients, and was significantly associated with younger age, male gender, lower body mass index, non-diabetic status, lack of peripheral vascular disease, and no angina. After adjusting for these factors, AVF versus graft use was still much higher in EUR than US (AOR=21, P < 0.0001). AVF use within facilities varied from 0 to 87% (median 21%) in the US, and 39 to 100% (median 83%) in EUR. For patients who were new to HD, access use was: 66% AVF in EUR versus 15% in US (AOR=39, P < 0.0001), 31% catheters in EUR vs. 60% in US, and 2% grafts in EUR vs. 24% in US. In addition, 25% of EUR and 46% of US incident patients did not have a permanent access placed prior to starting HD. In EUR, 84% of new HD patients had seen a nephrologist for> 30 days prior to ESRD compared with 74% in the US (P < 0.0001); pre-ESRD care was associated with increased odds of AVF versus graft use (AOR=1.9, P=0.01). New HD patients had a 1.8-fold greater odds (P=0.002) of starting HD with a permanent access if a facility's typical time from referral to access placement was < or =2 weeks. AVF use when compared to grafts was substantially lower (AOR=0.61, P=0.04) when surgery trainees assisted or performed access placements. When used as a patient's first access, AVF survival was superior to grafts regarding time to first failure (RR=0.53, P=0.0002), and AVF survival was longer in EUR compared with the US (RR=0.49, P=0.0005). AVF and grafts each displayed better survival if used when initiating HD compared with being used after patients began dialysis with a catheter. CONCLUSION: Large differences in vascular access use exist between EUR and the US, even after adjustment for patient characteristics. The results strongly suggest that a facility's preferences and approaches to vascular access practice are major determinants of vascular access use.

Adult↗

Membrane flux not biocompatibility determines beta-2-microglobulin levels in hemodialysis patients.

BACKGROUND: Serum beta(2)-microglobulin (beta(2)M) levels are important in dialysis-related amyloid deposition but can be influenced by dialysis technique. METHODS: We measured beta(2)M levels in 3 centres using different dialysis regimes. Centre 1 (73 patients) used high-flux biocompatible, centre 2 (72 patients) low-flux biocompatible and centre 3 (142 patients) cuprophane dialysers. RESULTS: beta(2)M levels were lower with high-flux biocompatible than with low-flux biocompatible or cuprophane dialysis (22.3 +/- 5.4 vs. 43.4 +/-13.7 and 37.6 +/-13.1 mg/l, respectively; p < 0.001). Levels were higher with low-flux biocompatible than with cuprophane dialysis (p < 0.001), but not if patients dialysed over 10 years were excluded. With low-flux biocompatible (47.4 +/- 9.8 vs. 38.7 +/- 15.2 mg/l; p < 0.01) and cuprophane dialysis (43.4 +/- 8.2 vs. 36.7 +/- 13.0 mg/l; p < 0.02), beta(2)M levels were higher in patients dialysed over 5 years than in those dialysed less. Despite beta(2)M levels increasing as residual renal function declined, there was no similar rise with high-flux biocompatible dialysis. CONCLUSIONS: Techniques allowing significant convection maintain lower beta(2)M levels over many years. Membrane flux, not biocompatibility, is the main determinant of beta(2)M levels in routine practice.

Aged↗