PubMed Health⌕ Search

Biomedical subjects

Roger Trones

Publications and source records attributed to Roger Trones.

4 recordsLinked to original sources

Temperature-programmed packed capillary liquid chromatography coupled to evaporative light-scattering detection and electrospray ionization time-of-flight mass spectrometry for characterization of high-molecular-mass hindered amine light stabilizers.

High-molecular weight-hindered amine light stabilizers (HMW-HALSs) are of utmost importance in modern polyolefin stabilization technology and in-depth knowledge about their chemical composition, particularly the oligomers, is essential for development of new and more efficient stabilizers. In the present study, the applicability of temperature-programmed packed capillary LC coupled to miniaturized ELSD and positive mode ESI-TOF-MS for analysis of HMW-HALSs is demonstrated through extensive characterization of two state-of-the-art stabilizers, i.e., HALS-1 and HALS-2. Both stabilizers were individually separated on a 320 microm i.d. x 35 cm long Hypersil 3 microm ODS-100 column using a temperature program from 30 to 120 degrees C and a quaternary mixture of ethylacetate, acetonitrile, triethylamine (TEA) and acetic acid (45.0:44.9:10.0:0.1 (v/v/v/v)) as the mobile phase. The effect of using various amounts of ethylacetate, acetonitrile and triethylamine in the mobile phase on the chromatographic separation is demonstrated. Furthermore, the LC-ESI-TOF-MS analyses revealed that HALS-1 (oligomeric) was highly complex and consisted of at least five different mass series, while HALS-2, which was assumed to be monomeric, contained two different mass series. Chemical structures for nearly all species of both stabilizers are proposed.

Amines↗

Isoelectric point separation of proteins by capillary pH-gradient ion-exchange chromatography.

In the present work, isoelectric point (pl) separation of proteins by pH-gradient ion-exchange chromatography (IEC) on packed capillary columns is demonstrated. The development of a miniaturized flow-through pH probe for reliable pH monitoring of the column effluent, which was an important technical challenge for adapting this technique to capillary dimensions, was solved by designing a low microliter per minute flow rate housing to a commercially available micro pH probe. Highly linear outlet pH-gradients within the pH range 8.5-4.0 were obtained when applying simple inexpensive buffers consisting solely of piperazine, N-methylpiperazine and imidazole on 10 cm x 0.32 mm i.d. fused silica capillaries packed with anion-exchange poly(styrene divinylbenzene)-based macroporous materials, i.e. 10 microm Mono P from Amersham Biosciences and 10 microm PL-SAX from PolymerLabs. Furthermore, when using a pH-gradient from 6.8 to 4.3, both columns were able to baseline separate the A and B genetic variants of beta-lactoglobulin, which differ with two amino acid residues only, but the PL-SAX column provided almost a two-fold decrease in peak widths compared to the Mono P column. The influence of varying the buffer concentration, injection volume and column temperature on the peak widths and resolution of the beta-lactoglobulins was investigated, e.g. a 100 microl sample of dilute beta-lactoglobulins was injected directly on the column with practically no increase in peak width as compared to what obtained with conventional injection volumes. Finally, a pH-gradient from 6.8 to 4.3 was used to separate proteins in skimmed bovine milk on the PL-SAX column. The milk was simply diluted 1:10 (v/v) with water and filtrated before injection.

Chromatography, Ion Exchange↗

Studies on the long-term thermal stability of particulate and monolithic poly(styrene-divinylbenzene) capillaries in reversed-phase liquid chromatography.

In the present study, the long-term high-temperature (>80 degrees C) and temperature programming stability of fused silica capillaries packed with 5 microm PLRP-S 300 A and monolithic PS-DVB capillaries (both 180 microm id x 6 cm) under reversed-phase conditions has been examined. In isothermal mode, the columns were defined as temperature-stable when a less than 10% change in apparent retention factors (k) and a less than 20% change in "retention time/peak width"-factors (n) of the probe solutes (proteins) were observed after passing 7,500 void volumes of effluent through the columns (about 100 h operation). According to these criteria, the PLRP-S and monolithic capillaries were defined temperature-stable at 100 and 130 degrees C, respectively. Furthermore, when continuously running temperature programs between 50 degrees C and the upper temperature limit determined in isothermal mode, virtually no change in k or n were observed on neither of the columns after running more than 35,000 void volumes or 1,600 temperature programs. Additionally, temperature-programmed reversed-phase separations of proteins on both types of capillaries are demonstrated and discussed.

Journal Article↗

Mesoporous polybutadiene-modified zirconia for high-temperature packed capillary liquid chromatography: column preparation and temperature programming stability.

In the present study, three different methods for packing of 3 microm PBD-ZrO2 particles in 0.5 mm i.d. glass-lined stainless steel columns have been examined. The two first methods were based on a traditional downstream high-pressure technique using tetrachloromethane (Method I) or aqueous Triton X-100 (Method II) as slurry solvents, while Method III was an upstream high-pressure flocculating method with stirring, using isopropanol both as the slurry and packing solvent. Method I was found to be superior in terms of efficiency, producing 0.5 mm i.d. x 10 cm columns with almost 90,000 plates m(-1) for toluene (R.S.D. = 8.7%, n = 3), using a slurry concentration of 600 mg ml(-1), ACN-water (50:50 (v/v)) as the packing solvent and a packing pressure of 650 bars. For Method I, the slurry concentration, column i.d., column length and initial packing pressure were found to have a significant effect on column efficiency. Finally, the long-term temperature stability of the prepared columns was investigated. In isothermal mode, using ACN-20 mM phosphate buffer, pH 7 (50:50 (v/v)) as the mobile phase, the columns were found to be stable for at least 3,000 void volumes at 100 degrees C. At this temperature, the solute efficiencies changed about 5-18% and the retention factors changed about 6-8%. In temperature programming mode (not exceeding 100 degrees C), on the other hand, a rapid decrease in both column efficiency and retention factors was observed. However, when the columns were packed as initially described, ramped up and down from 50 to 100 degrees C for 48 h and refilled, fairly stable columns with acceptable efficiencies were obtained. Although not fully regaining their initial efficiency after refilling, the solute efficiencies changed about 19-28% (32-37%) and the retention factors changed about 4-5% (13-17%) after running 3,000 (25,000) void volumes or 500 (3,900) temperature programs.

Butadienes↗