A pilot study of routine quality control of sampling by the SAD method, applied to packaged and bulk foods.

A recently proposed method of looking at sampling uncertainty has been tested by its application to the sampling and analysis of several types of food and an animal feedstuff. In this 'SAD' method, increments comprising the conventional sample (that is, collected in the fashion prescribed by the standard sampling protocol) are allocated to either of two equal sized 'splits', which are prepared and analysed separately. The absolute difference between the analytical results for the two splits (the split absolute difference, or SAD) is plotted on a one-sided control chart. A non-compliance indicates that the combined uncertainty of sampling or analysis is larger than expected and the result of the measurement (the mean of the two split results) is possibly not fit for purpose. In addition, the SAD results give rise to a rugged estimate the uncertainty associated with the sampling protocol, often a major part of the total measurement uncertainty.

Animals↗

Multi-analyte optimisation of uncertainty in infant food analysis.

The Optimised Uncertainty (OU) methodology has been developed to optimise multi-analyte situations. It has then been applied to a retail survey of infant food for trace elements, classifying the food as compliant or non-compliant with the regulatory thresholds or specification limits that are appropriate for each element. The large-scale survey of infant foods was successfully adapted to allow the estimation of uncertainties, from both primary sampling and chemical analysis, for elemental concentrations in infant formula (milk) and wet meals. The analytes included in this investigation comprised both contaminants (Pb and Cd) and elements essential for child development (Zn and Cu). Optimisation of the measurement process for a 'single analyte' demonstrated the potential financial benefits of optimising future surveys for a false compliance scenario. Uncertainty estimates for the measurement of elemental concentrations in infant formula were dominated by uncertainty from the analytical method. Large potential savings (up to pounds 575,000 per batch) are predicted for both Pb and Zn by increasing the expenditure on chemical analysis to the optimal level. In comparison the uncertainty estimates for elemental concentration in wet meals showed a dominance of sampling as a source of uncertainty for Cd and Cu due to the increased heterogeneity. The feasibility of 'multi-analyte' optimisation is demonstrated for the case study of infant milk. Single analyte optimisation of the four analytes for a false compliance scenario indicated a decrease in expectations of financial loss of between 99% and 8%. An overall decrease in the total expectation of financial loss of 99% is indicated following multi-analyte optimisation.

Child, Preschool↗

Measurement uncertainty from physical sample preparation: estimation including systematic error.

A methodology is proposed, which employs duplicated primary sampling and subsequent duplicated physical preparation coupled with duplicated chemical analyses. Sample preparation duplicates should be prepared under conditions that represent normal variability in routine laboratory practice. The proposed methodology requires duplicated chemical analysis on a minimum of two of the sample preparation duplicates. Data produced from the hierarchical design is treated with robust analysis of variance (ANOVA) to generate uncertainty estimates, as standard uncertainties ('u' expressed as standard deviation), for primary sampling (ssamp), physical sample preparation (sprep) and chemical analysis (sanal). The ANOVA results allow the contribution of the sample preparation process to the overall uncertainty to be assessed. This methodology has been applied for the first time to a case study of pesticide residues in retail strawberry samples. Duplicated sample preparation was performed under ambient conditions on two consecutive days. Multi-residue analysis (quantification by GC-MS) was undertaken for a range of incurred pesticide residues including those suspected of being susceptible to loss during sample preparation procedures. Sampling and analytical uncertainties dominated at low analyte concentrations. The sample preparation process contributed up to 20% to the total variability and had a relative uncertainty (Uprep%) of up to 66% (for bupirimate at 95% confidence). Estimates of systematic errors during physical sample preparation were also made using spike recovery experiments. Four options for the estimation of measurement uncertainty are discussed, which both include and exclude systematic error arising from sample preparation and chemical analysis. A holistic approach to the combination and subsequent expression of uncertainty is advised.

Calibration↗

Collaborative trials of the sampling of two foodstuffs, wheat and green coffee.

Two foodstuffs, wheat and green coffee, have been sampled from bulk lots by multiple samplers in the sampling analogue of a collaborative trial. For wheat the variation between samplers, contributing to the standard deviation of sampling reproducibility, was significant for two analytes. No significant sampling reproducibility variation was found in the coffee results, although significant sampling repeatability variation was detected.

Coffee↗

Optimised uncertainty in food analysis: application and comparison between four contrasting 'analyte-commodity' combinations.

The optimised uncertainty (OU) methodology is applied across a range of analyte-commodity combinations. The commodities and respective analytes under investigation were chosen to encompass a range of input factors: measurement costs (sampling and analytical), sampling uncertainties, analytical uncertainties and potential consequence costs which may be incurred as a result of misclassification. Two types of misclassification are identified-false compliance and false non-compliance. These terms can be used across a wide range of foodstuffs that have regulations requiring either minimum compositional requirements, maximum contaminant allowances or compositional specifications. The latter refers to foodstuffs with regulations that state an allowable tolerance around the compositional specification, i.e. the upper specification limit (USL) and the lower specification limit (LSL). The traditional OU methodology has been adapted so that it is applicable in these cases and has been successfully applied in practice. The Newton-Raphson method has been used to determine the optimal uncertainty value for the two case studies in which analyte concentration is assessed against a 'single threshold' regulatory requirement. This numerical method was shown to give a value of the optimal uncertainty that is practically identical to that given by the previously used method of visual inspection. The expectation of financial loss was reduced by an average of 65% over the four commodities by the application of the OU methodology, showing the benefit of the method.

Food Analysis↗

A comparison of the Kjeldahl and Dumas methods for the determination of protein in foods, using data from a proficiency testing scheme.

Both the Kjeldahl and the Dumas methods for the determination of protein in foodstuffs are currently in use, but the empirical nitrogen factors used to convert the determined nitrogen content to protein content are based on the Kjeldahl method alone. Non-equivalence between the two methods could therefore result in some laboratories reporting an incorrect protein content. We report here a study using data accumulated over several years in the results of a proficiency testing scheme. On average the Dumas method provided results that were relatively higher by about 1.4% than the Kjeldahl method, but the difference between the methods depended on the type of foodstuff. The methodology of looking for bias between analytical methods is critically discussed.

Food Analysis↗

Precision estimates produced by specially-designed ruggedness tests compared with those derived from collaborative trials, in relation to estimation of measurement uncertainty.

We have compared the reproducibility precisions provided by collaborative trials with precisions obtained from ruggedness tests specially designed to try to simulate between-laboratory variation. We found that the ruggedness tests underestimated the reproducibility variability consistently for those analytical methods requiring empirical calibration. The ruggedness tests provided on average a precision merely comparable with repeatability precision. This finding has implications for the estimation of uncertainty.

Food Analysis↗

Determination of ochratoxin A in currants, raisins, sultanas, mixed dried fruit, and dried figs by immunoaffinity column cleanup with liquid chromatography: interlaboratory study.

An interlaboratory study was performed on behalf of the Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in a variety of dried fruit at European regulatory limits. To ensure homogeneity before analysis, laboratory samples are normally slurried with water in the ratio of 5 parts fruit to 4 parts water, and test materials in this form were used in the study. The test portion was extracted with acidified methanol. The extract was filtered, diluted with phosphate-buffered saline, and applied to an affinity column. The column was washed and ochratoxin A was eluted with methanol. Ochratoxin A was quantified by reversed-phase LC. The use of post-column pH shift to enhance the fluorescence of ochratoxin A by the addition of 1.1 M ammonia solution to the column eluant is optional. Determination was by fluorescence. Currants, sultanas, raisins, figs, and mixed fruit (comprising dried pineapple, papaya, sultanas, prunes, dates, and banana chips), both naturally contaminated and blank (very low level), were sent to 24 collaborators in 7 European countries. Participants were asked to spike test portions of all test samples at a level equivalent to 5 ng/g ochratoxin A. Average recoveries ranged from 69 to 74%. Based on results for 5 naturally contaminated test samples (blind duplicates) the relative standard deviation for repeatability (RSDr) ranged from 4.9 to 8.7%, and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 28%. The method showed acceptable within- and between-laboratory precision for all 5 matrixes, as evidenced by HORRAT values <1.3.

Calibration↗