PubMed Health⌕ Search

Biomedical subjects

Rohan A Thakur

Publications and source records attributed to Rohan A Thakur.

3 recordsLinked to original sources

Atmospheric pressure photoionization. II. Dual source ionization.

In this paper we describe results based on the combination of atmospheric pressure photoionization (APPI) with atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The main purpose of combining more than one ionizer is to extend the range of compounds that can be simultaneously analyzed. Three modes of operation are presented; use of either ionizer, simultaneous use of two ionizers, and rapid switching between ionizers during a single chromatographic run. The dual ionizer configurations only minimally affect the performance of either ionizer relative to the standard single-ionizer sources. However, it is observed that the operation of both ionizers together does not typically give the sum signal from either source operating alone. For APCI/APPI the signal can range from less than that of either source alone to the sum of the two individual sources. For ESI/APPI, we observed large suppressions of the ESI multiply-charged signal of proteins when the APPI source was on. These behaviors are presumed to be due to the interaction of the initially formed ions by both sources and attests to the importance of ion-molecule reactions that occur during and after the primary ionization events. We give examples of compounds that are preferentially ionized by either APPI, APCI or ESI and present thermochemical arguments based on molecular structure and functionality to explain this behavior. The dual source is also shown to be able to operate in negative ion mode opening up the potential to conduct wide ranging chemical analyses.

Air Pressure↗

Purification of fusaproliferin from cultures of Fusarium subglutinans by preparative high-performance liquid chromatography.

Thirty-six Fusarium strains were grown on cracked yellow corn and evaluated for optimum fusaproliferin production, with Fusarium subglutinans E-1583 producing the highest levels (1600 microg/g). Three solvent systems were tested for extracting fusaproliferin from the cultures of F. subglutinans E-1583. Methanol gave the highest fusaproliferin recovery, followed by methanol/1% aqueous NaCl (55:45, v/v) and acetonitrile/methanol/H(2)O (16:3:1, v/v/v). Hexane partitioning was effective in removing many impurities from the crude fusaproliferin extracts prior to the liquid chromatography step. Fusaproliferin samples were further purified by high-performance liquid chromatography (HPLC) with a C18 preparatory column using a mobile phase of acetonitrile/H(2)O (80:20, v/v). The purity of the fusaproliferin was verified by analytical HPLC, GC/MS, (1)H NMR spectroscopy, and electrospray ionization (ESI) MS. The isolated fusaproliferin was shown to be free of impurities and can be used as a standard for routine analysis. Fusaproliferin was shown to be temperature-sensitive when samples were stored at room temperature (20-24 degrees C) for more than several days. After 30 days at 4 degrees C, approximately 8% of the fusaproliferin had been transformed to deacetyl-fusaproliferin; however, samples stored at -20 degrees C for 1 year contained only trace amounts of the deacetylated form.

Acetonitriles↗

A robust micro-electrospray ionization technique for high-throughput liquid chromatography/mass spectrometry proteomics using a sanded metal needle as an emitter.

A 60 microm internal diameter (i.d.) stainless-steel needle was adapted to the orthogonal ESI probe ( microESI) of a commercial ion trap mass spectrometer, and used for capillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) protein identification experiments. The modification allows for the use of nitrogen sheath gas which helps in the nebulization at LC flow rates exceeding 500 nL/min and eliminates problems caused by liquid junctions commonly used to initiate nanospray ionization (NSI). A comparison is made between the performance of a 75 microm i.d. column with a 15 microm pulled glass tip using a liquid junction, and that of a 150 microm i.d. column using the new microESI device. The combination of the 150 microm i.d. column and microESI gave sensitivity close to that of NSI (250 attomoles horse heart myoglobin digest on column), and proved to be more robust than the standard pulled glass tips of similar i.d. No evidence of metal needle catalyzed oxidation of methionine was observed during analysis of the tetrapeptide MRFA under a range of test conditions. Phosphorylated peptides in a beta-casein tryptic digest were also successfully identified using the microESI interface with a steel needle. In addition it was found that a mild sanding of the metal needle tip improved spray performance.

Animals↗