Roland Bammer

Publications and source records attributed to Roland Bammer.

13 recordsLinked to original sources

Single breath-hold diffusion-weighted imaging of the abdomen.

PURPOSE: To generate high quality diffusion-weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath-hold. MATERIALS AND METHODS: DWI was performed in 12 healthy subjects with an asymmetric, spin-echo, single-shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient was measured from maps and SNR was determined for both diffusion-weighted and reference images in the liver, spleen, pancreas, and kidneys. In six patients, single-axis diffusion encoding along three orthogonal axes (12 NEX) was employed to assess anisotropic diffusion in kidneys. RESULTS: This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion-weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 +/- 55) x 10(-6), (2580 +/- 53) x 10(-6), (1697 +/- 52) x 10(-6), (1047 +/- 82) x 10(-6), and (2605 +/- 168) x 10(-6) mm(2)/second, respectively (mean +/- SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t-test (P = 4.22 x 10(-10)). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively. CONCLUSIONS: 1) Single-shot SE EPI DWI in the abdomen with this technique provides high quality images and maps with full organ coverage in a single breath-hold; 2) ADCs obtained in the renal medulla and cortex are significantly different; and 3) diffusion within the renal medulla is moderately anisotropic.

Abdomen↗

Basic principles of diffusion-weighted imaging.

In diffusion-weighted MRI (DWI), image contrast is determined by the random microscopic motion of water protons. During the last years, DWI has become an important modality in the diagnostic work-up of acute ischemia in the CNS. There are also a few promising reports about the application of DWI to other regions in the human body, such as the vertebral column or the abdomen. This manuscript provides an introduction into the basics of DWI and Diffusion Tensor imaging. The potential of various MR sequences in concert with diffusion preparation are discussed with respect to acquisition speed, spatial resolution, and sensitivity to bulk physiologic motion. More advanced diffusion measurement techniques, such as high angular resolution diffusion imaging, are also addressed.

Artifacts↗

In vivo MR tractography using diffusion imaging.

Diffusion in structured tissue, such as white matter or muscle, is anisotropic. MR diffusion tensor imaging (DTI) measures anisotropy per pixel and provides the directional information relevant for MR tractography or fiber tracking in vivo. MR tractography is non-invasive, relatively fast, and can be repeated multiple times without destructing important tissue. Moreover, the combination with other MR images is relatively simple. In this paper, the basic principles of tractography are presented. Different tracking methods with varying degrees of complexity are introduced and their potential strengths and weaknesses are discussed. Clinical applications and different strategies for evaluating the fidelity of tracking results are reviewed.

Anisotropy↗

Line scan diffusion imaging of the spine.

BACKGROUND AND PURPOSE: Recent findings suggest that diffusion-weighted imaging might be an important adjunct to the diagnostic workup of disease processes in the spine, but physiological motion and the challenging magnetic environment make it difficult to perform reliable quantitative diffusion measurements. Multi-section line scan diffusion imaging of the spine was implemented and evaluated to provide quantitative diffusion measurements of vertebral bodies and intervertebral disks. METHODS: Line scan diffusion imaging of 12 healthy study participants and three patients with benign vertebral compression fractures was performed to assess the potential of line scan diffusion imaging of the spinal column. In a subgroup of six participants, multiple b-value (5-3005 s/mm(2)) images were obtained to test for multi-exponential signal decay. RESULTS: All images were diagnostic and of high quality. Mean diffusion values were (230 +/- 83) x 10(-6) mm(2)/s in the vertebral bodies, (1645 +/- 213) x 10(-6) mm(2)/s in the nuclei pulposi, (837 +/- 318) x 10(-6) mm(2)/s in the annuli fibrosi and ranged from 1019 x 10(-6) mm(2)/s to 1972 x 10(-6) mm(2)/s in benign compression fractures. The mean relative intra-participant variation of mean diffusivity among different vertebral segments (T10-L5) was 2.97%, whereas the relative difference in mean diffusivity among participants was 7.41% (P <.0001). The estimated measurement precision was <2%. A bi-exponential diffusion attenuation was found only in vertebral bodies. CONCLUSION: Line scan diffusion imaging is a robust and reliable method for imaging the spinal column. It does not suffer as strongly from susceptibility artifacts as does echo-planar imaging and is less susceptible to patient motion than are other multi-shot techniques. The different contributions from the water and fat fractions need to be considered in diffusion-weighted imaging of the vertebral bodies.

Adult↗

Inter-sequence and inter-imaging unit variability of diffusion tensor MR imaging histogram-derived metrics of the brain in healthy volunteers.

BACKGROUND AND PURPOSE: Diffusion tensor MR imaging has the potential to improve our ability to monitor several neurologic conditions. As a preliminary step to the assessment of the role of diffusion tensor MR imaging in the context of longitudinal and multicenter studies, we evaluated the effect of sequence-, imaging unit-, and imaging-reimaging-induced variations on diffusion tensor MR imaging quantities derived from histogram analysis of a large portion of the central brain of healthy volunteers. METHODS: Each of eight healthy volunteers underwent imaging on two MR imaging units using three different pulsed gradient spin-echo single shot echo-planar pulse sequences (each of them having a different diffusion gradient scheme). Four additional healthy participants underwent imaging twice on the same imaging unit to assess imaging-reimaging variability. RESULTS: For mean diffusivity histograms, the differences between inter-sequence and inter-imaging unit coefficients of variation were significant for all the considered quantities with P values ranging from.003 to <.001. Also, the inter-imaging unit coefficient of variation for average fractional anisotropy was significantly higher than the corresponding inter-sequence coefficient of variation (P =.002). In general, inter-sequence mean diffusivity histogram-derived metrics (coefficients of variation ranging from 1.72% to 5.56%) were more reproducible than were fractional anisotropy histogram-derived metrics (coefficients of variation ranging from 5.45% to 7.34%). Imaging-reimaging variability was found to fall in the range of inter-sequence coefficients of variation for all the considered quantities. CONCLUSION: This study shows that inter-sequence, imaging-reimaging, and inter-imaging unit variabilities of diffusion tensor MR imaging-derived measurements are relatively low, suggesting that diffusion tensor MR imaging might provide additional measures of outcome with which to assess the evolution of brain structural damage in large scale studies of various neurologic conditions.

Analysis of Variance↗

Diffusion-weighted imaging of the spinal cord: interleaved echo-planar imaging is superior to fast spin-echo.

PURPOSE: To compare and evaluate two novel diffusion-weighted sequences, based either on fast spin-echo (FSE) or interleaved echo-planar imaging (EPI) methods, as potential tools for investing spinal cord abnormalities. MATERIALS AND METHODS: Following recent improvements, both interleaved EPI (IEPI) and FSE techniques could be alternative approaches for rapid diffusion-weighted imaging (DWI). Therefore, a navigated diffusion-weighted multishot FSE sequence and a fat-suppressed navigated diffusion-weighted IEPI sequence with local shimming capabilities were tested. Both methods were compared in a consecutive series of five healthy volunteers and five patients with suspected intramedullary lesions. The sequences were graded qualitatively as either superior, inferior, or equal in quality, and also quantitatively by measuring the amount of ghosting artifacts in the background. Quantitative measurements of the diffusion coefficients within the spine were included. RESULTS: The overall image quality of IEPI was superior to FSE. Two out of five FSE scans were rated with poor image quality, whereas all IEPI scans were of sufficient quality. The ghosting levels ranged from approximately 3.3% to 6.2% for IEPI and from approximately 7.5% to 18.9% for FSE. Diffusion coefficients measured in healthy volunteers were similar for both IEPI and FSE, but showed higher fluctuations with the FSE technique. CONCLUSION: Despite potential advantages of FSE, the IEPI technique is preferable for DWI applications in the spinal cord.

Diffusion↗

Diffusion tensor imaging using single-shot SENSE-EPI.

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.

Brain↗

Diffusion-tensor imaging of cognitive performance.

MR methods have for some years been used to assess cognitive performance. Recently, studies have shown that diffusion-tensor imaging (DTI), which provides noninvasive maps of microscopic structural information of oriented tissue in vivo, is finding utility in studies of cognition in the normal and abnormal aging population. These studies suggest that water proton nonrandom, anisotropic diffusion measured by DTI is highly sensitive to otherwise subtle disease processes not easily seen with conventional MRI tissue contrast mechanisms and raises new issues of the role of MR in assessing cognitive potential.

Alzheimer Disease↗

Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: secondary signs.

PURPOSE: To assess the frequency of isoattenuating pancreatic adenocarcinoma with multi-detector row computed tomography (CT) and determine whether there are specific secondary signs that aid in detection. MATERIALS AND METHODS: Fifty-three patients with pancreatic adenocarcinoma underwent contrast material-enhanced biphasic multi-detector row CT with curved planar reformation. Tumors were initially deemed isoattenuating or hypoattenuating to normal pancreatic parenchyma on the basis of visual inspection, and the degree of attenuation was confirmed by calculating the mean attenuation differences between normal pancreatic parenchyma and tumor (tumor-pancreas contrast) during the pancreatic phase. Indirect signs of pancreatic tumor were tabulated in patients with an isoattenuating tumor. RESULTS: Of the 53 patients, six (11%) had isoattenuating tumors with a mean tumor-pancreas contrast of 9.25 HU +/- 11.3 during the pancreatic phase and 4.15 HU +/- 8.5 during the portal venous phase. The secondary signs of pancreatic tumor in these six patients included an interrupted pancreatic duct (n = 5), dilated biliary and pancreatic ducts (n = 1), atrophic distal pancreatic parenchyma (n = 3), and mass effect and/or convex contour abnormality (n = 3). The mean tumor-pancreas contrast for the remaining 47 patients was 74.76 HU +/- 35.61 during the pancreatic phase. CONCLUSION: With no visible tumor-pancreas contrast for isoattenuating tumors, indirect signs such as mass effect, atrophic distal parenchyma, and an interrupted duct sign are important indicators for the presence of tumor.

Adenocarcinoma↗

Local staging of pancreatic carcinoma with multi-detector row CT: use of curved planar reformations initial experience.

PURPOSE: To evaluate the utility of curved planar reformations compared with standard transverse images in the assessment of pancreatic tumors. MATERIALS AND METHODS: Forty-three patients suspected of having pancreatic tumors underwent contrast material-enhanced biphasic multi-detector row computed tomography (CT). Curved planar reformations were generated along the pancreatic duct, common bile duct, and major mesenteric vessels. Three blinded independent readers assessed the curved planar reformations and transverse images separately for the presence of tumor, resectability, and vascular involvement. The results were compared with those of a consensus panel who evaluated the curved planar reformations and transverse images together along with clinical data and surgical findings. RESULTS: Of 43 patients, 20 had pancreatic malignancies as judged by the consensus panel and proven at biopsy and/or clinical follow-up. For tumor detection, transverse images and curved planar reformations had an average sensitivity of 95.0% and 98.4% (P >.05), respectively, and an average specificity of 90.9% and 91.3% (P >.05), respectively. For tumor resectability, transverse images and curved planar reformations had an average sensitivity of 85.7% and 71.4% (P >.05), respectively, and an average specificity of 85.2% and 84.3% (P >.05), respectively. Average interpretation time was 6.4 minutes with transverse images and 4.1 minutes with curved planar reformations. CONCLUSION: Curved planar reformations are equivalent to transverse images in the detection of pancreatic tumors and determination of surgical resectability.

Adenocarcinoma↗

Vertebral metastases: assessment with apparent diffusion coefficient.

The authors evaluated the apparent diffusion coefficient (ADC) in the assessment of vertebral metastases and acute vertebral compression fractures in 22 patients with known or suspected vertebral metastases. On the basis of significantly (P <.03) different ADCs, vertebral metastases (0.69 x 10(-3) mm2/sec) and pathologic compression fractures (0.65 x 10(-3) mm2/sec) can be safely distinguished from vertebral bodies (1.66 x 10(-3) mm2/sec) and benign compression fractures (1.62 x 10(-3) mm2/sec). Thus, the use of ADCs may increase the specificity of magnetic resonance imaging in these patients.

Echo-Planar Imaging↗

CT angiography of the subclavian artery: utility of curved planar reformations.

Despite advances in the diagnosis and treatment of peripheral vascular occlusive disease, an ever-aging population continues to provide scores of new cases requiring medical care. While traditional angiography has been the mainstay of diagnosis for many years, newer, less invasive techniques such as CT angiography with three-dimensional reformation are rapidly establishing themselves as first-line diagnostic modalities. We present a case of severe left subclavian artery stenosis that demonstrates the utility of curved planar reformation in providing a concise visual summary of the pertinent anatomy and abnormalities.

Angiography↗