PubMed Health⌕ Search

Biomedical subjects

Roland R Wauer

Publications and source records attributed to Roland R Wauer.

At least 19 recordsLinked to original sources

Perfluorocarbons decrease Chlamydophila pneumoniae-mediated inflammatory responses of rat type II pneumocytes in vitro.

Chlamydophila pneumoniae alter the expression of Toll-like receptor (TLR) 4 in alveolar type II (ATII)-cells. Subsequently nuclear factor kappaB (NF-kappaB) is activated and tumor necrosis factor-alpha (TNF-alpha) and macrophage inflammatory protein 2 (MIP-2) are produced. Perfluorocarbons (PFC) are beneficial in animals with bacterial pneumonia and reduce production of TNF-alpha. Using isolated ATII-cells, it was studied whether PFC prevent C. pneumoniae-induced TNF-alpha and MIP-2 release and what the underlying pathway is. PF5080 preincubation prevented C. pneumoniae-induced secretion of TNF-alpha (43 +/- 10 versus 661 +/- 41 pg/mL) and MIP-2 (573 +/- 41 versus 4786 +/- 502 pg/mL). The C. pneumoniae-induced 2.2-fold increase of TNF-alpha Receptor 1 expression was reduced by PF5080. C. pneumoniae reduced cytoplasmatic IkappaBalpha (3.7 +/- 0.3 versus 14 +/- 1) and increased NF-kappaB p65 (31 +/- 7.5 versus 3.6 +/- 1.1) compared with control. PF5080 prevented NF-kappaB activation. TLR4 expression was 1.5-fold higher after C. pneumoniae incubation, but remained at control levels after PF5080 pretreatment. After 24 h of C. pneumoniae incubation, in 88 +/- 6% of cells bacteria were found in the perinuclear region and in 50% of these cells bacteria adhered to cellular surface. After PF5080 preincubation, C. pneumoniae were in 32 +/- 4% attached to and in 5 +/- 1% internalized in ATII-cells. Since PF5080 was found in ATII-cell membranes, PF5080 effect could be explained by an alteration of the cellular membrane, preventing activation of the inflammatory cascade.

Animals↗

Observational study to compare the clinical efficacy of the natural surfactants Alveofact and Curosurf in the treatment of respiratory distress syndrome in premature infants.

INTRODUCTION: Natural surfactants have been shown to be superior to synthetic surfactants in the treatment of neonatal respiratory distress syndrome (RDS). In Germany, Alveofact (A) and Curosurf (C) are the most frequently used natural surfactant preparations. The aim of this retrospective, observational study was to compare the effects of A and C on gas exchange and outcome in premature infants. METHODS: During a 5-year period in our neonatal intensive care unit (NICU), 187 premature infants were treated with surfactant, with 82 receiving A and 105 receiving C. We recorded F(I)O(2) and gas exchange (PaO(2)/F(I)O(2) ratio, PaCO(2), SaO(2)) during the first 72h after surfactant application and the incidence of outcome parameters at day 28 (bronchopulmonary dysplasia (BPD), intraventricular hemorrhage (IVH grade III or IV), patent ductus arteriosus (PDA), pneumothorax, necrotizing enterocolites (NEC) and death). The differences between the patient groups were assessed by ANOVA or the calculation of relative risks. Bonferroni correction was used for multiple comparisons. RESULTS: There were no statistically significant differences between infants treated with A and C in mean gestational age (28.4 vs. 28.4 weeks), birth weight (1210 vs.1258 g) and time of first surfactant application (60 vs. 90 min postnatal). We observed no significant between group differences in course of F(I)O(2) and blood gases, or in incidence at day 28 of BPD (41.7% vs. 42.8%), IVH III/IV (18.3% vs. 14.3%), pneumothorax (9.8% vs. 4.8%), PDA (23.2% vs. 21.9%), PVL (7.3% vs. 9.5%) and death (17% vs. 17.1%). There were also no statistically significant differences in the subgroup of infants <28 weeks. The lower incidence of NEC in A compared with C (1.2% vs. 10.5%, P=0.01) was not statistically significant after Bonferroni correction. CONCLUSION: Independent of gestational age no significant difference in the clinical efficacy of A and C was observed.

Biological Products↗

Somatostatin or octreotide as treatment options for chylothorax in young children: a systematic review.

OBJECTIVE: Chylothorax is a rare but life-threatening condition in children. To date, there is no commonly accepted treatment protocol. Somatostatin and octreotide have recently been used for treating chylothorax in children. We set out to summarise the evidence on the efficacy and safety of somatostatin and octreotide in treating young children with chylothorax. DESIGN: Systematic review: literature search (Cochrane Library, EMBASE and PubMed databases) and literature hand search of peer reviewed articles on the use of somatostatin and octreotide in childhood chylothorax. PATIENTS: Thirty-five children treated for primary or secondary chylothorax (10/somatostatin, 25/octreotide) were found. RESULTS: Ten of the 35 children had been given somatostatin, as i.v. infusion at a median dose of 204 microg/kg/day, for a median duration of 9.5 days. The remaining 25 children had received octreotide, either as an i.v. infusion at a median dose of 68 microg/kg/day over a median 7 days, or s.c. at a median dose of 40 microg/kg/day and a median duration of 17 days. Side effects such as cutaneous flush, nausea, loose stools, transient hypothyroidism, elevated liver function tests and strangulation-ileus (in a child with asplenia syndrome) were reported for somatostatin; transient abdominal distension, temporary hyperglycaemia and necrotising enterocolitis (in a child with aortic coarctation) for octreotide. CONCLUSIONS: A positive treatment effect was evident for both somatostatin and octreotide in the majority of reports. Minor side effects have been reported, however caution should be exercised in patients with an increased risk of vascular compromise as to avoid serious side effects. Systematic clinical research is needed to establish treatment efficacy and to develop a safe treatment protocol.

Child, Preschool↗

Functional residual capacity measurement by heptafluoropropane in ventilated newborn lungs: in vitro and in vivo validation.

OBJECTIVE: Heptafluoropropane is an inert gas commercially used as propellant for inhalers. Since heptafluoropropane can be detected in low concentrations, it could also be used as a tracer gas to measure functional residual capacity and ventilation homogeneity. The aim of the present study was to validate functional residual capacity measurements by heptafluoropropane wash-in/wash-out (0.8%) during mechanical ventilation in small, surfactant-depleted lungs using a newborn piglet model. DESIGN: Prospective laboratory and animal trial. SETTING: Animal laboratory in a university setting. SUBJECTS: Sixteen newborn piglets (age<12 hrs, median weight 1390 g [705-4200 g]) before and after surfactant depletion (Pao2<100 torr in Fio2=1.0) by lung lavage. INTERVENTIONS: Heptafluoropropane was measured with a new infrared mainstream sensor connected with the flow sensor of the Dräger Babylog 8000. Accuracy and precision of the measurement technique were tested in a mechanical lung model with a volume range from 11 to 35 mL. Reproducibility of the method and its sensitivity to detect changes of functional residual capacity were assessed in vivo by variation of ventilatory variables. MEASUREMENTS AND MAIN RESULTS: In vitro the absolute error of functional residual capacity was <1 mL (relative errors<3%) with a coefficient of variation<4%. The coefficient of variation of consecutive in vivo measurements was only slightly higher (<5.1%). Measurement of heptafluoropropane concentrations in blood showed no significant accumulation for repeated functional residual capacity measurements within short time periods. After lung lavage, the functional residual capacity decreased from 20.9 mL/kg to 14.5 mL/kg (p<.05) despite increased ventilatory pressures, and lung clearance index (p<.001) and moment ratios (p<.01) increased significantly due to uneven alveolar ventilation. In healthy lungs, the increase in peak inflation pressure and positive end-expiratory pressure by 3-4 cm H2O had only a moderate effect on functional residual capacity (20.9+/-8.6 vs. 26.0+/-11.9 mL/kg, p=.17) and no effect on ventilatory homogeneity, whereas in surfactant-depleted lungs the functional residual capacity increased from 14.5+/-6.7 mL/kg to 29.9+/-12.6 mL/kg (p<.001) and lung clearance index and moment ratios decreased significantly (p < .01). CONCLUSIONS: Heptafluoropropane is a suitable tracer gas for precise functional residual capacity measurements tested in vitro and allows for reproducible measurements in ventilated small lungs without any adverse effects on mechanical ventilation. The sensitivity of the method is sufficiently high to demonstrate the effect of changes in ventilatory settings on the functional residual capacity and ventilation homogeneity.

Administration, Inhalation↗

The Apgar score.

Explore the source record for details and available documents.

Apgar Score↗

A survey of transcutaneous blood gas monitoring among European neonatal intensive care units.

BACKGROUND: PCO2 and PO2 are important monitoring parameters in neonatal intensive care units (NICU). Compared to conventional blood gas measurements that cause significant blood loss in preterms, transcutaneous (tc) measurements allow continuous, non-invasive monitoring of blood gas levels. The aim of the study was to survey the usage and opinions among German speaking NICUs concerning tc blood gas monitoring. METHODS: A questionnaire was developed and sent to 56 head nurses of different NICUs in Germany, Switzerland and Austria. RESULTS: A completely answered questionnaire was obtained from 41 NICUs. In two of these units tc measurements are not performed. In most NICUs (77%), both PtcO2 and PtcCO2 are measured simultaneously. Most units change the sensors every 3 hours; however, the recommended temperature of 44 degrees C is used in only 15% of units. In only 8% of units are arterial blood gases obtained to validate tc values. Large variations were found concerning the targeted level of oxygen saturation [median upper limit: 95% (range 80-100%); median lower limit: 86% (range 75-93%)] and PO2 [median upper limit: 70 mmHg (range 45-90 mmHg); median lower limit: 44 mmHg (range 30-60 mmHg)]. CONCLUSION: Our survey shows that the use of tc monitors remains widespread among German speaking NICUs, despite earlier data suggesting that their use had been abandoned in many NICUs worldwide. In addition, we suggest that the current method of monitoring oxygenation may not prevent hyperoxemia in preterm infants.

Austria↗

Contact of Chlamydophila pneumoniae with type II cell triggers activation of calcium-mediated NF-kappa B pathway.

Nuclear factor-kappa B (NF-kappa B) plays an important role in inflammation, proliferation and regulation of apoptosis. The purpose of the present study on type II cells was to investigate whether Chlamydophila pneumoniae contact induces (I) a Ca2+ release, that (II) disrupts F-actin/beta-tubulin cytoskeletal association with NF-kappa B/I kappa B alpha, leading to (III) a subsequent NF-kappa B activation. Incubation of rat type II pneumocytes with C. pneumoniae caused an intracellular calcium release within seconds. Confocal laser scanning microscopy (CLSM) revealed that bacterial contact with cell surface leads to a disappearance of the microvilli and disturbs the co-localization between F-actin and NF-kappa B (p65). Using semi-quantitative CLSM, we show that at 10-30 min I kappa B alpha was decreased and p65 or p50 was simultaneously translocated from cytoplasm to the nucleus, resulting in a 19-fold and 17-fold increase versus control cells. During this time no bacteria were internalized into type II cells. The pre-treatment of cells with BAPTA-AM inhibited C. pneumoniae-mediated calcium release. BAPTA-AM or SN50 prevented the C. pneumoniae-induced changes in F-actin cytoskeleton and inhibited NF-kappa B activation. Paclitaxel reduced C. pneumoniae-mediated changes of beta-tubulin cytoskeleton and activation of NF-kappa B. These results suggest that calcium-mediated cytoskeleton reorganization is involved in C. pneumoniae-induced NF-kappa B activation in type II cells.

Actins↗

Inertance measurements by jet pulses in ventilated small lungs after perfluorochemical liquid (PFC) applications.

Perfluorochemical liquid (PFC) liquids or aerosols are used for assisted ventilation, drug delivery, lung cancer hyperthermia and pulmonary imaging. The aim of this study was to investigate the effect of PFC liquid on the inertance (I) of the respiratory system in newborn piglets using partial liquid ventilation (PLV) with different volumes of liquid. End-inspiratory (I(in)) and end-expiratory (I(ex)) inertance were measured in 15 ventilated newborn piglets (age < 12 h, mean weight 724 +/- 93 g) by brief flow pulses before and 80 min after PLV using a PFC volume (PF5080, 3 M) of 10 ml kg(-1) (N = 5) or 30 ml kg(-1) (N = 10). I was calculated from the imaginary part of the measured respiratory input impedance by regression analysis. Straight tubes with 2-4 mm inner diameter were used to validate the equipment in vitro by comparison with the analytically calculated values. In vitro measurements showed that the measuring error of I was <5% and that the reproducibility was better than 1.5%. The correlation coefficient of the regression model to determine I was >0.988 in all piglets. During gas ventilation, I(in) and I(ex) (mean +/- SD) were 31.7 +/- 0.8 Pa l(-1) s(2) and 33.3 +/- 2.1 Pa l(-1) s(2) in the 10 ml group and 32.4 +/- 0.8 Pa l(-1) s(2) and 34.0 +/- 2.5 Pa l(-1) s(2) in the 30 ml group. However, I of the 3 mm endotracheal tube (ETT) used was already 26.4 Pa l(-1) s(2) (about 80% of measured I). During PLV, there was a minimal increase of I(in) to 33.1 +/- 2.5 Pa l(-1) s(2) in the 10 ml group and to 34.5 +/- 2.7 Pa l(-1) s(2) in the 30 ml group. In contrast, the increase of I(ex) was dramatically larger (p < 0.001) to 67.7 +/- 13.3 Pa l(-1) s(2) and to 74.8 +/- 9.3 Pa l(-1) s(2) in the 10 ml and 30 ml groups, respectively. Measurements of I by jet pulses in intubated small animals are reproducible. PFC increases the respiratory inertance, but the magnitude depends considerably on its spatial distribution which changes during the breathing cycle. Large differences between I(in) and I(ex) are an indicator for liquid in airways or the ETT.

Administration, Inhalation↗

Human cytomegalovirus reactivation during lactation and mother-to-child transmission in preterm infants.

In a clinical trial, the incidence of cytomegalovirus reactivation in breastfeeding mothers and transmission to their preterm infants were studied. Breast milk from 73 mothers as well as urine and tracheal and pharyngeal aspirates from their 89 infants were screened weekly for human cytomegalovirus (HCMV) DNA during the first 2 months after delivery. Of the 73 mothers, 48 (66%) were positive for HCMV DNA in the lactating breast. HCMV reactivation could be confirmed for 19 of 20 (95%) immunoglobulin G-positive mothers. Of the eight immunoglobulin G-negative mothers one was positive for HCMV DNA in breast milk. In only 2 out of 13 seropositive mothers with HCMV DNA in breast milk could viral DNA be detected in the peripheral blood. HCMV mother-to-child transmission was concluded for 20 of the 48 (42%) mothers positive for DNA or 7 of 19 (37%) seropositive for HCMV and positive for HCMV DNA in breast milk and one of one mother seronegative for HCMV but positive for HCMV DNA in breast milk. One mother transmitted the virus to her twins. In addition, one infant acquired postnatal HCMV infection despite the mother's being negative for HCMV DNA in breast milk; altogether, we found 22 infants with HCMV infection. In 13 of these 22 infants, virus infection occurred definitively postnatally; two of them developed severe symptomatic HCMV infection. HCMV-infected infants demonstrated higher incidences of amniotic infection, respiratory distress syndrome, bronchopulmonary dysplasia, and retinopathia praenatalis than noninfected infants, however, the differences were not statistically significant. In summary, our study confirmed a very high incidence of HCMV reactivation in mothers during lactation and a significant risk of transmission to preterm infants with the possibility of severe disease in these babies.

Breast Feeding↗

Changes in FiO2 affect PaO2 with minor alterations in cerebral concentration of oxygenated hemoglobin during liquid ventilation in healthy piglets.

OBJECTIVE: To measure the impact of changes in the fraction of inspired oxygen (FiO2) on systemic and cerebral oxygen supply in gas and liquid ventilated healthy animals. DESIGN: Interventional prospective animal study. SETTING: University research laboratory. PARTICIPANTS: Ten healthy, new-born piglets. INTERVENTIONS: Variations in FiO2 during conventional mechanical ventilation (CMV) followed by partial liquid ventilation (PLV) with two different filling volumes of PF 5080 (10 vs. 30 ml/kg). MEASUREMENTS AND RESULTS: Arterial blood gases were obtained 15 min after changing FiO2 and concentrations of cerebral oxygenated and total hemoglobin were determined with near infrared spectroscopy. During CMV an increase in FiO2 1.0 was associated with a constant rise in PaO2 but only a small increase in the cerebral concentration of oxygenated Hb. Initiation of PLV (at FiO2 of 1.0) caused a rapid drop in PaO2 towards values that were similar to CMV at FiO2 of 0.5. At FiO2 of 0.5 a reduction in oxygenated Hb was found in the 30 ml/kg filling group. Complete filling of the lungs with PFC caused a significant drop in total cerebral Hb concentration. CONCLUSIONS. According to our data, PLV in healthy lungs should be performed with a FiO2 of 1.0 and a small filling volume to avoid deterioration in cerebral oxygen supply.

Animals↗

Perfluorocarbon species and nebulizer type influence aerosolization rate and particle size of perfluorocarbon aerosol.

PURPOSE: Aerosolization of perfluorocarbons (PFC) has been proven beneficial in vivo. The present in vitro study was performed to investigate, how PFC-aerosolization is affected by type of nebulizer and PFC properties. MATERIALS AND METHODS: Aerosolization rate was studied of 4 different PFC that were nebulized using 3 different jet nebulizers (operating at different flows: 4.1; 7.1; 13 l/min) and one ultrasonic nebulizer. Distribution of aerosol particle size was determined with a laser diffraction device. RESULTS: Between the studied nebulizers, considerable differences in the aerosolization rate were found. Aerosolization rate was significantly lower for PFOB (0.48-1.24 mL/min), when compared with PF 5080, RM 101 and FC 77 (1.33-4.75 mL/min). The ultrasonic nebulizer did not generate an aerosol but rather PFC vapor. Lowest mass median diameter (MMD) was found for PFOB and varied between the jet nebulizers from 2.2 and 3.7 microm, with a small range in particle size (maximum of 7.3 microm). FC 77 had highest MMD (3.5 to 9.2 microm) and greatest range of particle size of up to 13 microm. CONCLUSIONS: Our in vitro data show that aerosolization rate depends mainly on density of PFC and the flow of nebulizer. Particle size distribution is affected by PFC properties. Our result may explain controversial results of published in vivo studies.

Administration, Inhalation↗

Measurements of evaporated perfluorocarbon during partial liquid ventilation by a zeolite absorber.

UNLABELLED: During partial liquid ventilation (PLV) the knowledge of the quantity of exhaled perfluorocarbon (PFC) allows a continuous substitution of the PFC loss to achieve a constant PFC level in the lungs. The aim of our in vitro study was to determine the PFC loss in the mixed expired gas by an absorber and to investigate the effect of the evaporated PFC on ventilatory measurements. METHOD: To simulate the PFC loss during PLV, a heated flask was rinsed with a constant airflow of 4 L min(-1) and PFC was infused by different speeds (5, 10, 20 mL h(-1)). An absorber filled with PFC selective zeolites was connected with the flask to measure the PFC in the gas. The evaporated PFC volume and the PFC concentration were determined from the weight gain of the absorber measured by an electronic scale. The PFC-dependent volume error of the CO2SMO plus neonatal pneumotachograph was measured by manual movements of a syringe with volumes of 10 and 28 mL with a rate of 30 min(-1). RESULTS: Under steady state conditions there was a strong correlation (r2 = 0.999) between the infusion speed of PFC and the calculated PFC flow rate. The PFC flow rate was slightly underestimated by 4.3% (p < 0.01). However, this bias was independent from PFC infusion rate. The evaporated PFC volume was precisely measured with errors < 1%. The volume error of the CO2SMO-Plus pneumotachograph increased with increasing PFC content for both tidal volumes (p < 0.01). However for PFC flow rates up to 20 mL/h the error of the measured tidal volumes was < 5%. CONCLUSIONS: PFC selective zeolites can be used to quantify accurately the evaporated PFC volume during PLV. With increasing PFC concentrations in the exhaled air the measurement errors of ventilatory parameters have to be taken into account.

Absorption↗

Current limitations of volumetric capnography in surfactant-depleted small lungs.

OBJECTIVE: To investigate the suitability of volumetric capnography for assessing alveolar gas exchange in very small, surfactant-depleted lungs. DESIGN: Prospective animal trial. SETTINGS: Animal laboratory in a university setting. SUBJECTS: Twenty-one ventilated newborn piglets (age <12 hrs; median weight, 890 g; range, 560-1435 g). INTERVENTIONS: Bronchoalveolar lavage with instillation of 30 mL/kg normal saline. Ventilatory, circulatory, and lung mechanic variables were measured before and 0, 30, and 60 mins after bronchoalveolar lavage. MEASUREMENTS AND MAIN RESULTS: The alveolar deadspace fraction calculated by the Bohr and the Bohr/Enghoff equations increased three-fold (p<.001) after bronchoalveolar lavage in capnograms with distinct alveolar plateau, whereas in capnograms without alveolar plateau no statistical significant difference was seen. The main problem of capnography in small and especially stiff lungs was the high number of discarded records exclusively caused by a missing alveolar plateau. Rates of discarded records of capnography were 9.5% before lavage and increased (p<.01) to 52.4%, 47.6%,42.8% after bronchoalveolar lavage (0, 30, and 60 mins). With decreasing exhalation time, the number of discarded records increased significantly. No plateau was seen in >75% of recorded files with exhalation times <200 msecs. The effect of bronchoalveolar lavage on all variables measured was quite different, with the highest impact on required ventilatory settings, calculated oxygenation variables, and compliance. The effect of bronchoalveolar lavage on arterio-alveolar CO2 difference, CO2 production, and alveolar deadspace was much lower and statistically significant only in capnograms with alveolar plateau. CONCLUSIONS: Volumetric capnography is a useful tool to detect impaired alveolar gas exchange in surfactant-depleted small lungs. However, the method failed if there was no alveolar plateau in the volumetric capnogram especially in stiff lungs with short exhalation times.

Analysis of Variance↗

Extrasystoles: side effect of kangaroo care?

OBJECTIVE: To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. DESIGN: Case report. PATIENT: Preterm infant. MEASUREMENTS AND MAIN RESULTS: A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. CONCLUSIONS: ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

Cardiac Complexes, Premature↗

Comparison of two different CPAP systems by tidal breathing parameters.

OBJECTIVE: Comparison of tidal breathing and pressure fluctuation of the continuous positive airway pressure (CPAP) associated with the use of the valveless Infant Flow System versus the conventional constant-flow CPAP (Babylog 8000) in preterm infants. DESIGN: Randomized cross-over trial. SETTING: Neonatal intensive care unit level III. PATIENTS: Twenty infants; median (range): birth weight 1,035 g (640-4,110 g), actual weight 1,165 g (820-4,250 g), gestational age at birth 27 (26-40) weeks. INTERVENTIONS: After extubation two CPAP devices (Infant Flow System vs Babylog 8000) were applied in a random order to the same infant. Fluctuations of the applied pressure during the breathing cycle and tidal breathing parameters were measured by the flow-through technique. MAIN RESULTS: Using the Infant Flow System the mean (standard deviation) inspiratory flow [1.5 (0.1) vs 1.3 (0.1) l.min(-1).kg(-1), P<0.05] and tidal volume were significantly increased [5.3 (1.3) vs 4.7 (1.3) ml/kg(-1), P<0.05] compared to Babylog 8000. The fluctuations of the applied pressure of the Infant Flow System during the breathing cycle were significantly lower [0.1 (0.03) kPa vs 0.15 (0.08) kPa, P<0.05] compared to Babylog 8000. No differences were seen in the duration of inspiration and expiration and the time to peak tidal flow. In the Infant Flow System pressures during expiration remained stable whereas they increased during the use of Babylog 8000. CONCLUSIONS: Within-subject comparisons of tidal breathing parameters of the two CPAP devices Infant Flow System and Babylog 8000 show: (1) a significant influence of the system used; and (2) that the valveless Infant Flow System increases air flow and tidal volume with less fluctuations in CPAP pressures during the breathing cycle.

Germany↗

Aerosolization of perfluorocarbons during mechanical ventilation: an in vitro study.

OBJECTIVE: Inhalation of perfluorocarbons (PFC) has been suggested as a new and promising technique of PFC delivery in animal models of severe lung injury. However, no in vitro data were available on the efficacy of PFC aerosolization during mechanical ventilation. Therefore, the aim of the in vitro study was to investigate the influence of physical properties of PFC and the ventilatory settings on the amount of PFC delivered into the lung. DESIGN: In vitro lung model study. SETTING: University research laboratory. MEASUREMENTS AND RESULTS: Two different PFC (PF 5080 and PFOB) were aerosolized with a PariBoy jet nebulizer. Using a PFC selective adsorber, the effect of endotracheal tube size (2 mm and 3 mm diameter) on delivery of PFC was investigated. PFC delivery was estimated by continuous measurement of weight gain of the adsorber (adsorption rate). Finally, the influence of respiratory rate and tidal volume on adsorption rate (AR) was studied. AR was significantly reduced by a decreasing tube diameter and ranged from 1.45+/-0.03 ml/min (no tube) to 0.93+/-0.03 ml/min (2.0 mm) for PF 5080 (vapor pressure 51 mmHg) and from 0.49+/-0.06 ml/min to 0.32+/-0.04 ml/min for PFOB (11 mmHg). PFC-aerosolization into a ventilatory circuit with simulation of spontaneous tidal breathing (minute volume 600 ml) reduced AR to 0.16+/-0.02 ml/min. During mechanical ventilation, changes in respiratory rate and tidal volume, which reduce minute ventilation, caused a decrease in AR. CONCLUSION: The amount of PFC that can be delivered into the lung by aerosolization is very small and is influenced by PFC properties, tube size, and ventilatory settings.

Administration, Inhalation↗

Influence of preterm onset of inspiration on tidal breathing parameters in infants with and without CLD.

The preterm onset of inspiration (POI) is a well-known breathing strategy in newborns to increase their end-expiratory lung volume. The aim of this study was to investigate to which extent POI is related to tidal breathing (TB) parameters in healthy neonates (n=54) and infants with chronic lung diseases (CLD, n=45) with same postconceptional age. Using the deadspace free flow-through technique, 10-60 consecutive breaths were evaluated during quiet sleep and POI was derived from the averaged flow-volume loop considering the end-expiratory flow level. Respiratory rate (RR), ventilation (VE) and peak flows were significantly higher in CLD infants compared with controls. The incidence of POI did not differ significantly between both patient groups. POI is strongly associated with TB parameters describing the shape of flow profiles or flow-volume loops. In contrast, TB parameters, which depend only on breathing depth and rate (e.g., RR, VT, VE), were not significantly associated. The study shows that in infants TB parameters describing the flow profile may reflect differences in breathing strategy rather than impaired respiratory functions.

Chronic Disease↗