Amplitude-mapping effects on speech intelligibility with unilateral and bilateral cochlear implants.

OBJECTIVE: A study was conducted examining the effects of amplitude-mapping adjustments on speech intelligibility with bilateral cochlear implant users, for both unilateral and bilateral device use. The main motivation for this study was the consideration that bilateral loudness summation may result in sounds becoming too loud if no adjustments are made to standard monaural amplitude-mapping functions (maps) when used bilaterally. In that case, reductions of the stimulation levels may be needed. The objective was to assess the impact of such adjustments on speech intelligibility in noise and in quiet. DESIGN: Four different maps were compared in eight bilateral users of the Nucleus 24 system. Each map variation was taken home for 1 week and used bilaterally. After each week, the map used was tested both unilaterally and bilaterally using an adaptive speech-in-noise test and bilaterally for low-level speech in quiet. For the tests in noise, both speech and noise were presented from the same loudspeaker placed directly in front of the listener (S0N0). One of the maps evaluated was a standard clinical map, fitted as if only one ear were to be used. The three other maps used stimulation levels that were reduced more near the maximal stimulation levels, near thresholds, or else by a similar amount over the entire dynamic range. RESULTS: The data showed a modest but statistically significant decrease in performance when stimulation levels were lowered. This was true both in noise and in quiet. For level reductions corresponding to binaural loudness summation effects, the performance decrease was on the order of 1 to 2 dB. Altering the slope of the map had relatively little effect on performance. Comparison of unilateral with bilateral performance using the same map (i.e., no compensation for bilateral loudness summation) and with speech and noise both presented from in front of the listeners showed a modest but statistically significant improvement in the bilateral condition. CONCLUSIONS: Using higher stimulation levels in amplitude-mapping functions can improve both monaural and binaural speech perception performance in quiet and in noise, even when the slope of the acoustic to electrical amplitude-mapping function is held constant (i.e., when the electrical signal-to-noise ratio remains constant). The results in noise can be understood if we assume that the relation between electrical stimulation levels and loudness grows faster at higher stimulation levels. When comparing the monaural better ear with binaural performance in noise (S0N0) by using the same map, that is to say, when no adjustments were made in the bilateral condition for bilateral loudness summation, an average signal-to-noise ratio benefit of 1.4 dB was found in the bilateral condition. These findings indicate that when fitting bilateral devices clinically, although binaural performance may decrease slightly if levels need to be reduced to compensate for binaural loudness summation, the binaural S0N0 advantage over the better ear will offset this. Consequently, performance with both ears after adjustment is likely to remain at least as good as for the better ear alone without level adjustment, even in the S0N0 condition where binaural advantages are minimized.

Acoustic Stimulation↗

Evaluation of the neural response telemetry (NRT) capabilities of the nucleus research platform 8: initial results from the NRT trial.

The purpose of this study was to evaluate the performance of the new features of the Nucleus Research Platform 8 (RP8), a system developed specifically for research purposes The RP8 consists of a research implant, a speech processor and a new NRT software (NRT v4), and includes comparisons of the different artefact-cancellation methods, NRT threshold, and recovery function measurements. The system has new artefact-suppression techniques and new diagnostic capabilities; their performance has been verified in animal experiments. In this study, NRT data were collected from 15 postlingually deafened adult cochlear implant patients intraoperatively and up to 6 months postoperatively after switch-on. The initial investigation in two clinics in Europe focused primarily on the enhanced NRT capabilities Results from the trial in two European clinics indicate that NRT measurements can be obtained with lower noise levels. A comparison of the different artefact-cancellation techniques showed that the forward-masking paradigm implemented in the Nucleus 3 system is still the method of choice. The focus of this report is on recovery function characteristics, which may give insight into auditory nerve fiber properties with regard to higher stimulation rates.

Adolescent↗

Auditory brainstem implant part II: subjective assessment of functional outcome.

UNLABELLED: OBJECTIVE The purpose of this study was to present the patients' recommendations and judgments about their hearing and communication abilities with the help of the auditory brainstem implant. STUDY DESIGN: Prospective study. SETTING: Tertiary referral center. PATIENTS AND METHODS: This evaluation was based on the data obtained by the self-administered questionnaires designed for the European Auditory Brainstem Implant Multicenter Clinical Trial. Eleven patients who had used their auditory brainstem implant for a minimum of 6 months to a maximum of 41 months were evaluated with the help of these questionnaires. RESULTS: All the patients had used their implant on a regular daily basis for an average of 13 hours per day. None of them experienced any side effects during the daily use of the device. Nine patients (82%) used their auditory brainstem implant in both quiet and noisy surroundings. The most common cause of disturbance was a noisy surrounding. All the patients were able to distinguish speech from environmental sounds. The role of the auditory brainstem implant in differentiating various environmental sounds was considered to be very useful by 9 patients (82%). As an adjuvant to lip-reading, the auditory brainstem implant was considered most useful for understanding speech in quiet surroundings. DISCUSSION AND CONCLUSION: It was concluded that the auditory brainstem implant is an effective support for receiving and, to some degree, differentiating environmental sounds, and that as an adjuvant to lip-reading, it enhances speech perception, especially in quiet surroundings. A comparison between the results of this study and the results of the audiologic tests presented in Part I of this study (published earlier) revealed that patient satisfaction was not directly correlated with the results of the objective auditory tests. In general, patients' judgments of their individual hearing and communication abilities usually rated higher than could have been predicted by the objective audiometric data.