Effects of partial ventilatory support modalities on respiratory function in severe hypoxemic lung injury.

OBJECTIVE: The early phase of acute respiratory distress syndrome (ARDS) is characterized by impaired respiratory mechanics, ventilation-perfusion mismatch, and severe hypoxemia. Partial ventilatory support can effectively unload the respiratory workload and improve pulmonary gas exchange with less hemodynamic compromise. The partial ventilatory support mode most indicated in early phases of ARDS has not been determined. This study compares the effects of assisted ventilatory techniques on breathing pattern, gas exchange, hemodynamic function, and respiratory effort with those of controlled mechanical ventilation in similarly sedated subjects. DESIGN: Prospectively randomized crossover animal study. SETTING: Animal research laboratory. SUBJECTS: Eleven anesthetized and mechanically ventilated pigs. INTERVENTIONS: Acute lung injury was induced by lung lavage. Pressure-controlled ventilation (PCV), pressure-controlled assisted ventilation (P-ACV), bilevel positive airway pressure (BIPAP), and pressure support ventilation (PSV) with equal airway pressures and sedation were applied in random order. MEASUREMENTS AND MAIN RESULTS: Gas exchange, respiratory effort, and hemodynamic function were measured, and ventilation-perfusion distributions were calculated by multiple inert-gas-elimination techniques. The results revealed that partial ventilatory support was superior to PCV in maintaining adequate oxygenation and hemodynamic function with reduced sedation. The effects of P-ACV, BIPAP, and PSV were comparable with respect to gas exchange and hemodynamic function, except for a more pronounced reduction in shunt during BIPAP. P-ACV and PSV were superior to BIPAP to reduce respiratory drive and work of breathing. PSV affected the pattern of breathing and deadspace to a greater degree than did P-ACV. CONCLUSIONS: In acute lung injury, P-ACV preserves oxygenation and hemodynamic function with less respiratory effort compared with BIPAP and reduces the need for sedation compared with PCV.

Animals↗

Respiratory compliance but not gas exchange correlates with changes in lung aeration after a recruitment maneuver: an experimental study in pigs with saline lavage lung injury.

INTRODUCTION: Atelectasis is a common finding in acute lung injury, leading to increased shunt and hypoxemia. Current treatment strategies aim to recruit alveoli for gas exchange. Improvement in oxygenation is commonly used to detect recruitment, although the assumption that gas exchange parameters adequately represent the mechanical process of alveolar opening has not been proven so far. The aim of this study was to investigate whether commonly used measures of lung mechanics better detect lung tissue collapse and changes in lung aeration after a recruitment maneuver as compared to measures of gas exchange METHODS: In eight anesthetized and mechanically ventilated pigs, acute lung injury was induced by saline lavage and a recruitment maneuver was performed by inflating the lungs three times with a pressure of 45 cmH2O for 40 s with a constant positive end-expiratory pressure of 10 cmH2O. The association of gas exchange and lung mechanics parameters with the amount and the changes in aerated and nonaerated lung volumes induced by this specific recruitment maneuver was investigated by multi slice CT scan analysis of the whole lung. RESULTS: Nonaerated lung correlated with shunt fraction (r = 0.68) and respiratory system compliance (r = 0.59). The arterial partial oxygen pressure (PaO2) and the respiratory system compliance correlated with poorly aerated lung volume (r = 0.57 and 0.72, respectively). The recruitment maneuver caused a decrease in nonaerated lung volume, an increase in normally and poorly aerated lung, but no change in the distribution of a tidal breath to differently aerated lung volumes. The fractional changes in PaO2, arterial partial carbon dioxide pressure (PaCO2) and venous admixture after the recruitment maneuver did not correlate with the changes in lung volumes. Alveolar recruitment correlated only with changes in the plateau pressure (r = 0.89), respiratory system compliance (r = 0.82) and parameters obtained from the pressure-volume curve. CONCLUSION: A recruitment maneuver by repeatedly hyperinflating the lungs led to an increase of poorly aerated and a decrease of nonaerated lung mainly. Changes in aerated and nonaerated lung volumes were adequately represented by respiratory compliance but not by changes in oxygenation or shunt.

Animals↗

S-100 protein and neurohistopathologic changes in a porcine model of acute lung injury.

BACKGROUND: Survivors of acute respiratory distress syndrome exhibit neuropsychological sequelae that might be attributable to hippocampal damage. The authors sought to determine the effects of hypoxemia in a pig model of acute lung injury on the hippocampal region and the release of S-100 protein in comparison to a control group in which hypoxemia was induced by reducing the inspired oxygen fraction. METHODS: Hypoxemia was induced in 14 female pigs by repeated lung lavages (lung injury group; n = 7) or by reducing the inspired oxygen fraction (hypoxia-only group; n = 7). Hemodynamic variables, gas exchange, and serum concentrations of S-100 protein were measured at baseline, after induction of acute lung injury, and subsequently for 12 h. Animals were euthanized, and the brains were removed for histopathologic examination. RESULTS: Comparable blood gases were seen in both groups. Serum S-100 protein concentrations were comparable for both groups at baseline. At all other time points, S-100 concentrations were significantly higher in the lung injury group. Neuropathologic examination showed basophilic and shrunken neurons of the pyramidal cell layer in the hippocampal CA1 subregion of all pigs in the lung injury group. Few abnormalities were seen in the hypoxia-only group. CONCLUSIONS: The same degree of hypoxemia induced in a lavage model of acute lung injury results in greater brain damage assessed by S-100 protein and histopathologic findings when compared to a group in which hypoxemia at the same degree was induced by reducing the inspired oxygen fraction. This suggests that acute lung injury leads to neuropathologic changes independent of hypoxemia.

Animals↗

Repeated generation of the pulmonary pressure-volume curve may lead to derecruitment in experimental lung injury.

OBJECTIVE: Measurements from the pulmonary pressure-volume (PV) curve have been proposed to adjust ventilator settings. We investigated the effects of repeated construction of an inflation PV curve implemented in a standard ventilator on recruitment or derecruitment in acutely injured lungs. DESIGN AND SETTING: Prospective experimental animal study in eight anesthetized and mechanically ventilated pigs. INTERVENTIONS: Acute lung injury was induced by lung lavage and animals were ventilated in volume controlled mode with PEEP 10 cmH(2)O. The PV curve was constructed five times repeatedly by constant pressure rise, after which ventilation with the preset PEEP was resumed immediately. Studies of hemodynamics, lung mechanics, blood gases and computed tomography were carried out before and after maneuvers. MEASUREMENTS AND RESULTS: Derecruitment was assessed as an increase in nonaerated lung volume (V(NON)), and V(PEEP) was the end-expiratory volume difference between PEEP and ZEEP. There was a significant decrease in PaO(2) from 90.4+/-33.3 to 70.9+/-36.3 mmHg and a rise in venous admixture from 47.8+/-12.7 to 59.1+/-16.6%. V(PEEP) was reduced from 244 to 202 ml. A corresponding decrease in normally aerated lung volume was observed, while regression analysis revealed increase in V(NON) depending on the amount of preexisting atelectasis. CONCLUSIONS: Repeated generation of the PV curve with a readily available tool resulted in worsened oxygenation. Derecruitment of the lungs occurred with loss of PEEP at the start of the maneuver, which could not be recovered by a maximum inflation pressure of 40 cmH(2)O. Repeated use of the investigated tool should be cautioned, and users should consider measures to preserve aerated lung volumes.

Animals↗

Ventilation with biphasic positive airway pressure in experimental lung injury. Influence of transpulmonary pressure on gas exchange and haemodynamics.

OBJECTIVE: We investigated whether improvement in ventilation perfusion (.V(A)/.Q) distribution during mechanical ventilation using biphasic positive airway pressure (BIPAP) with spontaneous breathing may be attributed to an effectively increased transpulmonary pressure (P(TP)) and can also be achieved by increasing P(TP) during controlled ventilation. DESIGN: In 12 pigs with saline lavage-induced lung injury we compared the effects of BIPAP to pressure-controlled ventilation with equal airway pressure (PCV(AW)) or equal transpulmonary pressure (PCV(TP)) on V(A)/.Q distribution assessed by the multiple inert gas elimination technique (MIGET). SETTING: Animal laboratory study. MEASUREMENTS AND RESULTS: Intrapulmonary shunt was 33+/-11% during BIPAP, 36+/-10% during PCV(AW) and 33+/-15% during PCV(TP) ( p= n.s.). BIPAP resulted in higher PaO(2) than PCV(AW) (188+/-83 versus 147+/-82 mmHg, p < 0.05), but not than PCV(TP) (187+/-139 mmHg). Oxygen delivery was significantly higher during BIPAP (530+/-109 ml/min) versus 374+/-113 ml/min during PCV(AW) and 353+/-93 ml/min during PCV(TP) ( p < 0.005). Tidal volume with PCV(TP) increased to 11.9+/-2.3 ml/kg, compared to 8.5+/-0.8 with BIPAP and 7.6+/-1.4 with PCV(AW) ( p <0.001) and cardiac output decreased to 3.5+/-0.6 l/min (BIPAP 4.9+/-0.8 and PCV(AW) 3.9+/-0.8, p<0.006). CONCLUSIONS: In experimental lung injury, BIPAP with preserved spontaneous breathing was effective in increasing regional P(TP), since pressure-controlled ventilation with the same P(TP) resulted in similar gas exchange effects. However, PCV(TP) caused increased airway pressures and tidal volumes, whereby, with BIPAP, less depression of oxygen delivery and cardiac output were observed. BIPAP could be useful in maintaining pulmonary gas exchange and slightly improving oxygenation without interfering with circulation as strongly as PCV does.

Animals↗

Ventilation-perfusion distribution related to different inspiratory flow patterns in experimental lung injury.

UNLABELLED: In acute lung injury (ALI), controlled mechanical ventilation with decelerating inspiratory flow (.V(dec)) has been suggested to improve oxygenation when compared with constant flow (.V(con)) by improving the distribution of ventilation and perfusion (.V(A)/.Q). We performed the present study to test this hypothesis in an animal model of ALI. Furthermore, the effects of combined decelerating and constant flow (Vdot;(deco)) were evaluated. Thus, 18 pigs with experimental ALI were randomized to receive mechanical ventilation with either .V(con), .V(dec) or a fixed combination of both flow wave forms (.V(deco)) at the same tidal volume and positive end-expiratory pressure level for 6 h. Hemodynamics, gas exchange, and .V(A)/.Q distribution were determined. The results revealed an improvement of oxygenation resulting from a decrease of pulmonary shunt within each group (P < 0.05). However, blood flow to lung areas with a normal .V(A)/.Q distribution increased only during ventilation with .V(con) (P < 0.05). Accordingly, PaO(2) was higher with .V(con) than with .V(dec) and .V(deco) (P < 0.05). We conclude that contrary to the hypothesis, .V(con)provides a more favorable .V(A)/.Q distribution, and hence better oxygenation, when compared with .V(dec) and .V(deco) in this model of ALI. IMPLICATIONS: In acute lung injury, mechanical ventilation with decelerating flow has been suggested to improve ventilation-perfusion distribution when compared with constant flow. We tested this hypothesis in an animal model. Contrary to the hypothesis, we found a more favorable ventilation-perfusion distribution during constant flow when compared with decelerating flow.

Airway Resistance↗

Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury.

In most severe cases of the acute respiratory distress syndrome, veno-venous extracorporeal membrane oxygenation (ECMO) can be used to facilitate gas exchange. However, the clinical use is limited due to the size and the concomitant risk of severe adverse events of conventionally-used centrifugal blood pumps with high extracorporeal blood volumes. The DeltaStream blood pump is a small-sized rotary blood pump that may reduce extracorporeal blood volume, foreign surfaces, contact activation of the coagulation system, and blood trauma. The aim of the present study was to test the safety and efficacy of the DeltaStream pump for ECMO in animals with normal lung function and experimental acute lung injury (ALI). Therefore, veno-venous ECMO was performed for 6 hours in mechanically ventilated pigs with normal lung function (n=6) and with ALI induced by repeated lung lavage (n=6) with a blood flow of 30% of the cardiac output. Gas flow with a FiO2 of 1.0 was set to equal blood flow. With a mean activated clotting time of 121 +/- 22 s, no circulatory impairment or thrombus formation was revealed during ECMO. Furthermore, free plasma Hb did not increase. In controls, hemodynamics and gas exchange remained unchanged. In animals with ALI, hemodynamics remained stable and gas transfer across the extracorporeal oxygenators was optimal, but only in 2 animals was a marked increase in PaO2 observed. CO2 removal was efficacious in all animals. We concluded that the DeltaStream blood pump may be used for veno-venous ECMO without major blood damage or hemodynamic impairment.

Animals↗

Modulating the pulmonary circulation: an update.

PURPOSE OF REVIEW: Disorders of the pulmonary circulation might develop as a primary disease process of the pulmonary vascular bed or, more often, as the acute or chronic consequence of pulmonary or cardiac pathologies. For the anaesthesiologist and intensivist it is particularly interesting to gain insight into the regulation of the pulmonary circulation since pulmonary hypertension and concomitant right heart failure contribute to high perioperative mortality rates in patients at risk, especially after cardiac surgery. Therefore, modulation of the pulmonary circulation may be a life-saving therapy in patients suffering from acute or chronic pulmonary circulatory disorders. Furthermore, routinely performed intra-operative interventions such as the use of volatile anaesthetics or cardiopulmonary bypass systems may have relevant side effects on the pulmonary circulation. RECENT FINDINGS: This review focuses on new insights into the modulation of pulmonary circulation during general anaesthesia with volatile anaesthetics and anaesthesiological management during cardiopulmonary surgery. Recent publications in the field of cardiopulmonary bypass surgery, one-lung ventilation and heart and lung transplantation are discussed. Furthermore, the role of conventional and experimental therapeutic strategies to modulate pulmonary circulation in intensive care medicine is reviewed. SUMMARY: Despite the performance of a large number of clinical and experimental studies, the pathophysiology of pulmonary circulatory disorders is not completely understood. Therefore, any new therapy has to be carefully evaluated as a therapeutic option. Several formerly experimental therapeutic interventions such as inhaled vasodilators, however, appear to have found their way into clinical practice for selected indications.

Journal Article↗

Low-dose multislice spiral computed tomography in acute lung injury: animal experience.

RATIONALE AND OBJECTIVES: To compare low-dose multislice spiral CT (MSCT) with a standard protocol for the evaluation of acute lung injury (ALI) in an animal model. MATERIALS AND METHODS: Eleven healthy intubated pigs (weight: 32.4 kg +/- 1.9 kg) underwent lung lavage to induce experimental lung injury before CT examinations. Scanning was performed using a MSCT-technique. The entire chest was scanned using a thin-collimated protocol (140 kV; 100 mAs). The examinations were performed in inspiratory breath-hold in supine and in prone positions. Scanning was repeated after reduction of the tube current time product down to 20 mAs. All other parameters were kept constant. Subjective image quality was rated using a six-point scale by three experienced radiologists. In addition, objective criteria, based on signal to noise measurements, were assessed. Finally, the extent, localization, and distribution of lung opacities was analyzed using dedicated postprocessing software. RESULTS: Subjective image quality was rated inferior in the low-dose MSCT-examinations (prone position: 2.1 vs. 3.0; supine position: 1.5 vs. 2.5). Hence, pixel noise was nearly doubled. However, exact information about the extent, localization and distribution of lung opacities was provided. There were no statistically significant differences between standard and low-dose MSCT in this respect. CONCLUSIONS: In the animal experiments, low-dose MSCT-scanning did not impair the diagnostic accuracy in ALI, offering an advantageous reduction of radiation exposure.

Animals↗

High-frequency oscillatory ventilation in experimental lung injury: effects on gas exchange.

OBJECTIVE: To compare ventilation-perfusion (V(A)/Q) distributions during improvement of oxygenation caused by high-frequency oscillatory ventilation (HFOV) and pressure-controlled mechanical ventilation with high PEEP levels (CMV) in experimental acute lung injury (ALI). DESIGN: Prospective, controlled animal study. SETTING: Animal research facility of a university hospital. INTERVENTIONS: Twelve pigs with oleic acid-induced ALI were randomised to HFOV ( n=6) or to CMV ( n=6) with a PEEP of 15 mbar for 1 h. The mean airway pressure was adjusted in both groups to achieve comparable improvements in arterial oxygen partial pressure (PaO(2)) and to avoid clinically relevant impairments of cardiac output, as assured by adequate mixed venous oxygen saturation and lactate levels. V(A)/Q distributions were determined by the multiple inert gas elimination technique (MIGET). MEASUREMENTS AND RESULTS: Arterial oxygen partial pressure improved during CMV with a mean airway pressure of 20 mbar ( p<0.05) whereas HFOV revealed comparable improvements with a mean airway pressure of 40 mbar ( p<0.05). Shunt decreased and blood flow to normal V(A)/Q areas increased due to CMV and HFOV ( p<0.05). The perfusion of low V(A)/Q areas remained unchanged. Statistical analysis did not reveal differences of PaO(2), shunt or blood flow to low V(A)/Q areas between the groups. CONCLUSIONS: In this model of acute lung injury CMV and HFOV improved gas exchange due to similar changes in V(A)/Q distribution. However, mean airway pressure had to be adjusted twofold higher during HFOV then during CMV to achieve comparable improvements in gas exchange.

Animals↗

Pressure support compared with controlled mechanical ventilation in experimental lung injury.

UNLABELLED: It has been suggested that, in acute lung injury (ALI), spontaneous breathing activity may increase oxygenation because of an improvement of ventilation-perfusion distribution. Pressure support ventilation (PSV) is one of the assisted spontaneous breathing modes often used in critical care medicine. We sought to determine the prolonged effects of PSV on gas exchange in experimental ALI. We hypothesized that PSV may increase oxygenation because of an improvement in ventilation-perfusion distribution. Thus, ALI was induced in 20 pigs by using repetitive lung lavage. Thereafter, the animals were randomized to receive either PSV with a pressure level set to achieve a tidal volume >4 mL/kg and a respiratory rate <40 min(-1) (n = 10) or controlled mechanical ventilation (CMV) with a tidal volume of 10 mL/kg and a respiratory rate of 20 min(-1) (n = 10). Positive end-expiratory pressure was set at 10 cm H(2)O in both groups. Blood gas analyses and determination of ventilation-perfusion (.V(A)/.Q) distribution were performed at the onset of ALI and after 2, 4, 8, and 12 h. The main result was an improvement of oxygenation because of a decrease of pulmonary shunt and an increase of areas with normal .V(A)/.Q ratios during PSV (P < 0.005). However, during CMV, a more pronounced reduction of shunt was observed compared with PSV (P < 0.005). We conclude that, in this model of ALI, PSV improves gas exchange because of a reduction of .V(A)/.Q inequality. However, improvements in .V(A)/.Q distribution may be more effective with CMV than with PSV. IMPLICATIONS: Assisted spontaneous breathing may have beneficial effects on gas exchange in acute lung injury. We tested this hypothesis for pressure support ventilation in an animal model of acute lung injury. Our results demonstrate that pressure support does not necessarily provide better gas exchange than controlled mechanical ventilation.

Air Pressure↗