Myocardial metabolism is better preserved after blood cardioplegia in infants.

BACKGROUND: We have previously reported improved hemodynamic function after blood cardioplegia in comparison with crystalloid cardioplegia. Furthermore, lactate was released from the heart after crystalloid cardioplegia but not after blood cardioplegia. The purpose of this study was to determine whether the difference in substrate metabolism between the two cardioplegia methods was restricted to lactate, or whether the difference in metabolic derangement was more extensive. METHODS: Thirty consecutive infants with complete atrioventricular septal defects were included in this prospective, randomized, controlled study. Arterial and coronary sinus blood concentrations of substrates and amino acids were measured after weaning from bypass. RESULTS: After crystalloid cardioplegia, there was a myocardial uptake of glutamate (p = 0.003), leucine (p = 0.03), lysine (p = 0.003), and beta-hydroxybutyrate (p = 0.004), whereas lactate was released (p = 0.03). After blood cardioplegia, there was a myocardial uptake of free fatty acids (p = 0.01) but no uptake of amino acids and no release of lactate. CONCLUSIONS: There are differences in myocardial substrate metabolism between blood cardioplegia and crystalloid cardioplegia, which involve carbohydrates and amino acids. The differences may include lipids but our data in this respect are not conclusive.

3-Hydroxybutyric Acid↗

Blood cardioplegia provides superior protection in infant cardiac surgery.

BACKGROUND: We hypothesized that blood cardioplegia preserves myocardial metabolism and function more effectively than St Thomas' crystalloid cardioplegia in infant cardiac surgery. METHODS: Thirty infants with atrioventricular septal defects were randomly allocated to either blood or crystalloid intermittent cold (4 degrees C) cardioplegia. Arterial and coronary sinus blood was analyzed for lactate and oxygen. Cardiac output (thermodilution) and left ventricular function (echocardiography) were evaluated. RESULTS: The lactate concentration in coronary sinus blood early after bypass was significantly higher after crystalloid cardioplegia than after blood cardioplegia (2.1 +/- 0.3 vs 1.3 +/- 0.1 mmol/L, p = 0.006), with a significant myocardial release of lactate after crystalloid but not after blood cardioplegia. Oxygen extraction (arterial-coronary sinus O2 content) was higher early after crystalloid cardioplegia (3.02 +/- 0.13 vs 2.35 +/- 0.22 mmol/L, p = 0.01), possibly reflecting a difference in oxygen debt. The cardiac index was higher after blood cardioplegia (4.9 +/- 0.3 vs 4.0 +/- 0.3 L/min(-1)/m(-2), p = 0.04) and echocardiographic grading of left ventricular function was better (4.1 +/- 0.17 vs 3.5 +/- 0.22 arbitrary units, p = 0.046). CONCLUSIONS: This study indicates that blood cardioplegia preserves myocardial metabolism and function more effectively than crystalloid cardioplegia in infant cardiac surgery. The clinical significance of this finding is uncertain, but the more than 20% increase in cardiac index in the critical phase during weaning from bypass may be advantageous.

Biomarkers↗

Changes in hemostasis during pediatric heart surgery: impact of a biocompatible heparin-coated perfusion system.

BACKGROUND: This study describes the response in hemostasis during open-heart surgery with cardiopulmonary bypass (CPB) in children (<== 10 kg) and tests the hypothesis that the use of a biocompatible perfusion system, in comparison with a conventional system, causes less hemostatic activation. METHODS: Prospective, randomized, controlled clinical study. Forty consecutive children <== 10 kg were included and divided into two groups: group bioc. (n = 19) treated with a fully heparin-coated system, centrifugal pump, and a closed circuit, and group conv. (n = 21) treated with an uncoated system, roller pump, and a hard shell venous reservoir. Concentrations of plasma thrombin-antithrombin (TAT), D-dimer, tissue plasminogen activator antigen (t-PA ag), and the complex consisting of tissue plasminogen activator and its inhibitor plasminogen activator inhibitor-1 (t-PA-PAI-1) were measured. RESULTS: The biochemical variables measured increased significantly in both groups during the study period. There was less activation of fibrinolysis during cardiopulmonary bypass (t-PA ag: p = 0.009) in patients treated with the biocompatible perfusion system than in patients treated with the conventional system. A trend in favor of the biocompatible system based on the D-dimer and TAT data (p = 0.07 for both measurements) was observed but no significant intergroup differences regarding these variables or t-PA-PAI-1 were found. CONCLUSIONS: Open-heart surgery with cardiopulmonary bypass in children (<== 10 kg) causes transient activation of the coagulation and fibrinolytic systems. This study demonstrates that the use of a biocompatible perfusion system results in a lower extent of activation of fibrinolysis during CPB than the use of a conventional system.

Anticoagulants↗

A closed perfusion system with heparin coating and centrifugal pump improves cardiopulmonary bypass biocompatibility in elderly patients.

BACKGROUND: Cardiopulmonary bypass induces a systemic inflammatory and hemostatic activation, which may contribute to postoperative complications. Our aim was to compare the inflammatory response, coagulation, and fibrinolytic activation between two different perfusion systems: one theoretically more biocompatible with a closed-circuit, complete heparin coating, and a centrifugal pump, and one conventional system with uncoated circuit, roller pump, and a hard-shell venous reservoir. METHODS: Forty-one elderly patients (mean age, 73 +/- 1 years, 66% men) undergoing coronary artery bypass grafting or aortic valve replacement were included in a prospective, randomized study. Plasma concentrations of complement factors (C3a, C4d, Bb, and sC5b-9), proinflammatory cytokines (tumor necrosis factor-alpha, interleukin-6, and interleukin-8), granulocyte degradation products (polymorphonuclear elastase), and markers of coagulation (thrombin-antithrombin) and fibrinolysis (D-dimer, tissue plasminogen activator antigen and tissue plasminogen activator-plasminogen activator inhibitor-1 complex) were measured preoperatively, at bypass during rewarming (35 degrees C), 60 minutes after bypass, and on day 1 after surgery. RESULTS: The mean concentrations of C3a (-39%; p = 0.008), Bb (-38%; p < 0.001), sC5b-9 (-70%; p < 0.001), interleukin-8 (-60%; p = 0.009), polymorphonuclear-elastase (-55%; p < 0.003), and tissue plasminogen activator antigen (-51%; p = 0.012) were all significantly lower in the biocompatible group during rewarming. Sixty minutes after bypass, the mean concentrations of sC5b-9 (-39%; p = 0.006) and polymorphonuclear-elastase (-55%; p < 0.001) were lower in the biocompatible group. CONCLUSIONS: The results suggest that a closed perfusion system with a heparin-coated circuit and a centrifugal pump may improve cardiopulmonary bypass biocompatibility in elderly cardiac surgery patients in comparison with a conventional system.

Aged↗

Influence of two different perfusion systems on inflammatory response in pediatric heart surgery.

BACKGROUND: This study tests the hypothesis that a cardiopulmonary bypass system that combines complete heparin-coating, a centrifugal pump, and a closed circuit in comparison with a conventional system (uncoated system, roller pump, and hard shell venous reservoir) attenuates the inflammatory response in pediatric heart surgery. METHODS: In a prospective randomized controlled clinical study 40 consecutive children weighing 10 kg or less were included and divided into two groups. Concentrations of complement proteins (C3a, sC5b-9, C4d, and Bb), granulocyte degranulation products (polymorphonuclear [PMN] elastase), and proinflammatory cytokines (tumor necrosis factor [TNF]-alpha, interleukin [IL]-6, and IL-8) were measured. RESULTS: C3a and sC5b-9 concentrations were lower (C3a, p < 0.001; sC5b-9, p = 0.01) in the combined (heparin-coated/centrifugal pump/closed reservoir) group, the peak values being 58% and 37% of conventional group values. The Bb- and C4d-fragment values indicated activation of the complement system through the alternative pathway in both groups. PMN elastase concentrations were lower (p = 0.02) in the combined group, the peak values being 43% of conventional group values. There were no significant intergroup differences regarding TNF-alpha, IL-6, or IL-8 concentrations. CONCLUSIONS: The use of a fully heparin-coated system, a centrifugal pump, and a closed circuit during CPB in children (10 kg or less) leads to a lower degree of complement activation and PMN elastase release compared with a conventional system.

Adolescent↗

Predictors of allograft ischemic injury in clinical heart transplantation.

OBJECTIVES: 1. Identify clinical, biochemical and inflammatory predictors of allograft ischemic injury in clinical heart transplantation. 2. Evaluate the impact of high dose insulin (GIK) on allograft metabolism during blood cardioplegia and post-ischemic injury. DESIGN: A clinical, prospective, randomized open trial comprising 25 consecutive heart transplantations at a university hospital. Ischemic injury was evaluated from plasma levels of creatine kinase isoenzyme MB (CK-MB). Blood cardioplegic arterial and coronary sinus concentrations of C3a, IL-6, substrates, amino acids and blood gases were measured at the end of the implantation period, prior to reperfusion. Twelve patients received high dose insulin with glucose, potassium and amino acids. RESULTS: CK-MB increased from 1.9 +/- 0.2 to 161 +/- 13 microg/l (range 47-293 microg/l). The peak level of CK-MB correlated with donor age (r = 0.48, p = 0.02) and implantation time (r = 0.53, p = 0.02); and with recipient plasma IL-6 (r = 0.56, p = 0.02), allograft oxygen extraction (r = 0.56, p = 0.02), lactate release (r = 0.47, p = 0.02) and allograft arterial-coronary sinus (cs) pH (r = 0.47, p = 0.02) all during final cardioplegia before reperfusion. Seventy-two percent of the variance of CK-MB was explained by a model which included donor age, art-cs pH difference and arterial IL-6. In contrast, CK-MB was unrelated to total ischemic time (r = -0.17, p = 0.38). Insulin infusion had no effect on myocardial substrates during cardioplegia, or on post-ischemic CK-MB. CONCLUSION: Donor age, duration and quality of the implantation period are significant predictors of allograft ischemic injury in heart transplantation. High dose insulin had no detectable effects on allograft metabolism during cardioplegia, or on subsequent ischemic injury.

Adolescent↗