Closed-loop control of mean arterial blood pressure during surgery with alfentanil: clinical evaluation of a novel model-based predictive controller.

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Adult↗

A new closed-loop control system for isoflurane using bispectral index outperforms manual control.

BACKGROUND: Automatic control of depth of hypnosis using the Bispectral Index (BIS) can help to reduce phases of inadequate control. Automated BIS control with propofol or isoflurane administration via an infusion system has recently been described, a comparable study with isoflurane administration via a vaporizer had not been conducted yet. Our hypothesis was that our new model based closed-loop control system can safely be applied clinically and maintains the BIS within a defined target range better than manual control. METHODS: Twenty-three patients, American Society of Anesthesiologists risk class I-III, scheduled for decompressive spinal surgery were randomized into groups with either closed-loop or manual control of BIS using isoflurane. An alfentanil target-controlled infusion was adjusted according to standard clinical practice. The BIS target was set to 50 during the operation. The necessity of human intervention in the control system and events of inadequate sedation (BIS <40 or BIS >60) were counted. The number of phases of inadequate control, defined as BIS >/=65 for more than 3 min, were recorded. The performance of the controller was assessed by several indicators (mean absolute deviation and median absolute performance error) and measured during the skin incision phase, the subsequent low flow phase, and the wound closure phase. Recovery profiles of both groups were compared. RESULTS: No human intervention was necessary in the closed-loop control group. The occurrence of inadequate BIS was quantified with the mean and median values of the area under the curve and amounted to 0.360 and 0.088 for the manual control group and 0.049 and 0.017 for the closed-loop control group, respectively. In the manual control group nine phases of inadequate control were recorded, compared with one in the closed-loop control group, 10.3% to 0.5% of all observed anesthesia time. During all phases the averages of the performance parameters (mean absolute deviation and median absolute performance error) were more than 30% smaller in closed-loop control than in manual control (P < 0.05 between groups). CONCLUSIONS: Closed-loop control with BIS using isoflurane can safely be applied clinically and performs significantly better than manual control, even in phases with abrupt changes of stimulation that cannot be foreseen by the control system.

Adolescent↗

A new paradigm for the closed-loop intraoperative administration of analgesics in humans.

We present a new paradigm for the closed-loop administration of analgesics during general anesthesia. The manipulated variable in the control system is the infusion rate of the opiate alfentanil, administered intravenously through a computer-controlled infusion pump (CCIP). The outputs to be controlled are the patient's mean arterial pressure (MAP) and the drug concentration in the plasma. Maintaining MAP within appropriate ranges provides optimal treatment of the patient's reactions to surgical stimuli. Maintaining plasma drug concentrations close to a reference value specified by the anesthesiologist allows to titrate analgesic administration to qualitative clinical end-points of insufficient analgesia. MAP is acquired invasively through a catheter cannula. Since plasma drug concentrations cannot be measured on-line, they are estimated via a pharmacokinetic model. We describe an explicit model-predictive controller which achieves the above-mentioned objectives. An upper constraint on drug concentrations is maintained to avoid overdosing. Constraints on the MAP are introduced to trigger a prompt controller reaction during hypertensive and hypotensive periods. Measurement artifacts in the MAP signal are rejected to prevent harmful misbehavior of the controller. We discuss the results of the clinical validation of the controller on humans.

Alfentanil↗