Backbone carbonyl group basicities are related to gas-phase fragmentation of peptides and protein folding.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Roman A Zubarev.
Explore the source record for details and available documents.
The recent proliferation of novel mass spectrometers such as Fourier transform, QTOF, and OrbiTrap marks a transition into the era of precision mass spectrometry, providing a 2 orders of magnitude boost to the mass resolution, as compared to low-precision ion-trap detectors. We investigate peptide de novo sequencing by precision mass spectrometry and explore some of the differences when compared to analysis of low-precision data. We demonstrate how the dramatically improved performance of de novo sequencing with precision mass spectrometry paves the way for novel approaches to peptide identification that are based on direct sequence lookups, rather than comparisons of spectra to a database. With the direct sequence lookup, it is not only possible to search a database very efficiently, but also to use the database in novel ways, such as searching for products of alternative splicing or products of fusion proteins in cancer. Our de novo sequencing software is available for download at http://peptide.ucsd.edu/.
An approach to sequence-dependent retention time prediction of peptides based on the concept of liquid chromatography at critical conditions (LCCC) is presented. Within the LCCC approach applied to biopolymers (BioLCCC), the specific retention time corresponds to a particular sequence. In combination with mass spectrometry, this approach provides an efficient tool to solve problems wherein the protein sequencing is essential. In this work, we present a theoretical background of the BioLCCC concept and demonstrate experimentally its feasibility for sequence-dependent LC retention time prediction for peptides. BioLCCC model is based on three notions: (a) a random walk model for a macromolecule chain; (b) an entropy and energy compensation for the macromolecules within the adsorbent pore; and (c) a set of phenomenological parameters for the effective interaction energies of interactions between the amino acid residues and the adsorbent surface. In this work, the phenomenological parameters have been obtained for C18 reversed-phase HPLC. Note, that contrary to alternative additive models for retention time prediction based on summation of the so-called "retention coefficients", the BioLCCC approach takes into account the location of amino acids within the primary structure of a peptide and, thus, allows the identification of the peptides having the same composition of amino acids but differing by their arrangement. As a result, this new approach allows prediction of retention time for any possible amino acid sequence in particular HPLC experiments. In addition, the BioLCCC model lacks of main drawbacks of additive approaches that predict retention time for sequences of limited chain lengths and provide information about amino acid composition only. The proposed BioLCCC approach was characterized experimentally using LTQ FT LC-MS and LC-MS/MS data obtained earlier for Escherichia coli. The HPLC system calibration was performed using peptide retention standards. The results received show a linear correlation between predicted and experimental retention times, with a correlation coefficient, R2, of 0.97 for a peptide standard mixture and 0.9 for E. coli data, respectively, with the standard error below 1 min. The work presents the first description of a BioLCCC approach for high-throughput peptide characterization and preliminary results of its feasibility tests.
Hydrogen rearrangement is an important process in radical chemistry. A high degree of H. rearrangement to and from z. ionic fragments (combined occurrence frequency 47% compared with that of z.) is confirmed in analysis of 15,000 tandem mass spectra of tryptic peptides obtained with electron capture dissociation (ECD), including previously unreported double H. losses. Consistent with the radical character of H. abstraction, the residue determining the formation rate of z' = z. + H. species is found to be the N-terminal residue in z. species. The size of the complementary c(m)' fragment turned out to be another important factor, with z' species dominating over z. ions for m < or = 6. The H. atom was found to be abstracted from the side chains as well as from alpha-carbon groups of residues composing the c' species, with Gln and His in the c' fragment promoting H. donation and Asp and Ala opposing it. Ab initio calculations of formation energies of .A radicals (A is an amino acid) confirmed that the main driving force for H. abstraction by z. is the process exothermicity. No valid correlation was found between the NC(alpha) bond strength and the frequency of this bond cleavage, indicating that other factors than thermochemistry are responsible for directing the site of ECD cleavage. Understanding hydrogen attachment to and loss from ECD fragments should facilitate automatic interpretation ECD mass spectra in protein identification and characterization, including de novo sequencing.
A new method of detecting the presence of deprotonation and determining its position in gas-phase polypeptide cations is described. The method involves 157-nm ultra-violet photodissociation (UVPD) and is based on monitoring the losses of CO2 (44 Da) from electronically excited deprotonated carboxylic groups relative to competing COOH losses (45 Da) from neutral carboxylic groups. Loss of CO2 is a strong indication of the presence of a zwitterionic [(+)...(-)...(+)] salt bridge in the gas-phase polypeptide cation. This method provides a tool for studying, for example, the nature of binding within polypeptide clusters. Collision-activated dissociation (CAD) of decarboxylated cations localizes the position of deprotonation. Fragment abundances can be used for the semiquantitative assessment of the branching ratio of deprotonation among different acidic sites, however, the mechanism of the fragment formation should be taken into account. Cations of Trp-cage proteins exist preferentially as zwitterions, with the deprotonation position divided between the Asp9 residue and the C terminus in the ratio 3:2. The majority of dications of the same molecule are not zwitterions. Furthermore, 157-nm UVPD produces abundant radical cations M*+ from protonated molecules through the loss of a hydrogen atom. This method of producing M*+ ions is general and can be applied to any gas-phase peptide cation. The abundance of the molecular radical cations M*+ produced is sufficient for further tandem mass spectrometry (MS/MS), which, in the cases studied, yielded side-chain loss of a basic amino acid as the most abundant fragmentation channel together with some backbone cleavages.
The complexity of the human proteome, already enormous at the organism level, increases further in the course of the proteome analysis due to in vitro sample evolution. Most of in vitro alterations can also occur in vivo as post-translational modifications. These two types of modifications can only be distinguished a posteriori but not in the process of analysis, thus rendering necessary the analysis of every molecule in the sample. With the new software tool ModifiComb applied to MS/MS data, the extent of modifications was measured in tryptic mixtures representing the full proteome of human cells. The estimated level of 8-12 modified peptides per each unmodified tryptic peptide present at >or=1% level is approaching one modification per amino acid on average. This is a higher modification rate than was previously thought, posing an additional challenge to analytical techniques. The solution to the problem is seen in improving sample preparation routines, introducing dynamic range-adjusted thresholds for database searches, using more specific MS/MS analysis using high mass accuracy and complementary fragmentation techniques, and revealing peptide families with identification of additional proteins only by unfamiliar peptides. Extensive protein separation prior to analysis reduces the requirements on speed and dynamic range of a tandem mass spectrometer and can be a viable alternative to the shotgun approach.
Explore the source record for details and available documents.
A major challenge in proteomics is to fully identify and characterize the post-translational modification (PTM) patterns present at any given time in cells, tissues, and organisms. Here we present a fast and reliable method ("ModifiComb") for mapping hundreds types of PTMs at a time, including novel and unexpected PTMs. The high mass accuracy of Fourier transform mass spectrometry provides in many cases unique elemental composition of the PTM through the difference DeltaM between the molecular masses of the modified and unmodified peptides, whereas the retention time difference DeltaRT between their elution in reversed-phase liquid chromatography provides an additional dimension for PTM identification. Abundant sequence information obtained with complementary fragmentation techniques using ion-neutral collisions and electron capture often locates the modification to a single residue. The (DeltaM, DeltaRT) maps are representative of the proteome and its overall modification state and may be used for database-independent organism identification, comparative proteomic studies, and biomarker discovery. Examples of newly found modifications include +12.000 Da (+C atom) incorporation into proline residues of peptides from proline-rich proteins found in human saliva. This modification is hypothesized to increase the known activity of the peptide.
Separation of the functions of ion excitation and detection between different cell compartments allows for implementation of excitation and detection techniques unattainable in a single compartment of the conventional ion cyclotron resonance (ICR) cell. In particular, multi-electrode detection at a multiple of the main cyclotron frequency can be utilized without the loss of sensitivity and other negative effects. The new O-trap designed exclusively for ion detection adds an additional, internal coaxial cylinder around which ions with excited cyclotron orbits rotate. Comparison of simulated performance characteristics of the new O-trap with those of the same-size conventional cylindrical cell shows that the O-trap can provide higher sensitivity and ion capacity. Multiplexing of the O-traps can further increase the analysis speed. Future efforts will be aimed at building and testing experimentally the coaxial O-trap, including optimization of the method of ion transfer between the compartments of the cell.
A database independent search algorithm for the detection of phosphopeptides is described. The program interrogates the tandem mass spectra of LC-MS/MS data sets regarding the presence of phosphorylation specific signatures. To achieve maximum informational content, the complementary fragmentation techniques electron capture dissociation (ECD) and collisionally activated dissociation (CAD) are used independently for peptide fragmentation. Several criteria characteristic for peptides phosphorylated on either serine or threonine residues were evaluated. The final algorithm searches for product ions generated by either the neutral loss of phosphoric acid or the combined neutral loss of phosphoric acid and water. Various peptide mixtures were used to evaluate the program. False positive results were not observed because the program utilizes the parts-per-million mass accuracy of Fourier transform ion cyclotron resonance mass spectrometry. Additionally, false negative results were not generated owing to the high sensitivity of the chosen criteria. The limitations of database dependent data interpretation tools are discussed and the potential of the novel algorithm to overcome these limitations is illustrated.
Explore the source record for details and available documents.
Tandem mass spectrometry (MS/MS) utilizing both electron capture dissociation (ECD) and collisionally activated dissociation (CAD) was used to develop a qualitative and quantitative analytical method for chiral analysis of individual amino acid residues in polypeptides. ECD produced a more distinct chiral recognition than CAD, which is attributed to the smaller degree of vibrational excitation in ECD. Several peptide and protein model systems were used in this study, including the smallest known protein, tryptophan cage, a lactoferrin peptide, and the biologically relevant opioid peptide, dermorphin. An adaptation of the kinetic method was used to quantify the degree of separation between fragmentation patterns of stereoisomeric peptides as a function of fragment ion abundances. The obtained calibration scale for relative abundances of d-amino acids in diastereomeric peptide mixtures was accurate to 1% for ECD and to 3-5% for CAD. It was found that separation and quantification of stereoisomers could be advantageously performed by nanoflow reversed-phase liquid chromatography, with the objective of on-line MS/MS limited to stereoisomer identification. This technique shows promise for the analysis of chiral substitution in peptides and proteins, broadening the application area for tandem mass spectrometry.
The Mascot score (M-score) is one of the conventional validity measures in data base identification of peptides and proteins by MS/MS data. Although tremendously useful, M-score has a number of limitations. For the same MS/MS data, M-score may change if the protein data base is expanded. A low M-value may not necessarily mean poor match but rather poor MS/MS quality. In addition M-score does not fully utilize the advantage of combined use of complementary fragmentation techniques collisionally activated dissociation (CAD) and electron capture dissociation (ECD). To address these issues, a new data base-independent scoring method (S-score) was designed that is based on the maximum length of the peptide sequence tag provided by the combined CAD and ECD data. The quality of MS/MS spectra assessed by S-score allows poor data (39% of all MS/MS spectra) to be filtered out before the data base search, speeding up the data analysis and eliminating a major source of false positive identifications. Spectra with below threshold M-scores (poor matches) but high S-scores are validated. Spectra with zero M-score (no data base match) but high S-score are classified as belonging to modified sequences. As an extension of S-score, an extremely reliable sequence tag was developed based on complementary fragments simultaneously appearing in CAD and ECD spectra. Comparison of this tag with the data base-derived sequence gives the most reliable peptide identification validation to date. The combined use of M- and S-scoring provides positive sequence identification from >25% of all MS/MS data, a 40% improvement over traditional M-scoring performed on the same Fourier transform MS instrumentation. The number of proteins reliably identified from Escherichia coli cell lysate hereby increased by 29% compared with the traditional M-score approach. Finally S-scoring provides a quantitative measure of the quality of fragmentation techniques such as the minimum abundance of the precursor ion, the MS/MS of which gives the threshold S-score value of 2.
A new technique called selective excitation of ions for consecutive activation (SEICA) is proposed for obtaining complementary fragmentation mass spectra from the same precursor ion population. SEICA utilizes precursor ions remaining intact after electron capture dissociation or another ion-electron reaction for efficient MS/MS based on a vibrational excitation (VE) technique, such as infrared multiphoton dissociation. SEICA uses the ability of ion-trapping instruments to detect product ions while retaining inside the trap intact precursor ions, making the latter available for consecutive activation by a VE technique. The possibility of practical implementation of SEICA by software-only modification of a commercial instrument is demonstrated. A 2-fold increase in the efficiency is achieved for both "single-scan" and "multiple-scan" experiments. This improvement can be particularly important for high-sensitivity applications in, for example, proteomics, where limited ECD efficiency poses an obstacle for broad implementation of this technique.
Identification of proteins by MS/MS is performed by matching experimental mass spectra against calculated spectra of all possible peptides in a protein data base. The search engine assigns each spectrum a score indicating how well the experimental data complies with the expected one; a higher score means increased confidence in the identification. One problem is the false-positive identifications, which arise from incomplete data as well as from the presence of misleading ions in experimental mass spectra due to gas-phase reactions, stray ions, contaminants, and electronic noise. We employed a novel technique of reduction of false positives that is based on a combined use of orthogonal fragmentation techniques electron capture dissociation (ECD) and collisionally activated dissociation (CAD). Since ECD and CAD exhibit many complementary properties, their combined use greatly increased the analysis specificity, which was further strengthened by the high mass accuracy (approximately 1 ppm) afforded by Fourier transform mass spectrometry. The utility of this approach is demonstrated on a whole cell lysate from Escherichia coli. Analysis was made using the data-dependent acquisition mode. Extraction of complementary sequence information was performed prior to data base search using in-house written software. Only masses involved in complementary pairs in the MS/MS spectrum from the same or orthogonal fragmentation techniques were submitted to the data base search. ECD/CAD identified twice as many proteins at a fixed statistically significant confidence level with on average a 64% higher Mascot score. The confidence in protein identification was hereby increased by more than 1 order of magnitude. The combined ECD/CAD searches were on average 20% faster than CAD-only searches. A specially developed test with scrambled MS/MS data revealed that the amount of false-positive identifications was dramatically reduced by the combined use of CAD and ECD.
Fragmentation of peptide polyanions by electron detachment dissociation (EDD) has been induced by electron irradiation of deprotonated polypeptides [M-nH](n-) with >10 eV electrons. EDD has been found to lead preferentially to a* and x fragment ions (C(alpha)-C backbone cleavage) arising from the dissociation of oxidized radical anions [M-nH]((n-1)-*. We demonstrate that C(alpha)-C cleavages, which are otherwise rarely observed in tandem mass spectrometry, can account for most of the backbone fragmentation, with even-electron x fragments dominating over radical a* ions. Ab initio calculations at the B3 LYP level of theory with the 6-311+G(2 p,2 d)//6-31+G(d,p) basis set suggested a unidirectional mechanism for EDD (cleavage always N-terminal to the radical site), with a*, x formation being favored over a, x* fragmentation by 74.2 kJ mol(-1). Thus, backbone C(alpha)-C bonds N-terminal to proline residues should be immune to EDD, in agreement with the observations. EDD may find application in mass spectrometry for such tasks as peptide sequencing and localization of labile post-translational modifications, for example, those introduced by sulfation and phosphorylation. EDD can now be performed not only in Fourier transform mass spectrometry, but also in far more widely used quadrupole (Paul) ion traps.
In-source decay (ISD) in matrix-assisted laser desorption/ionization (MALDI) shares some similarities with the novel fragmentation technique electron capture dissociation (ECD). In both reactions, the otherwise strong N-C(alpha) bond is cleaved, forming fragment ions of the c and z types, while labile posttranslational modifications are preserved. Therefore, it is tempting to assume that ISD and ECD have some mechanistic aspects in common. Because electrons are present in the MALDI plume, we investigated the previously suggested possibility that ISD is a variation of ECD. However, experiments with peptides with only one site for efficient protonation revealed that ISD is not caused by electron capture. Instead, ICD seems to be induced by hydrogen atoms generated by a photochemical reaction of the matrix. We provide evidence for this reaction by hydrogen/deuterium exchange experiments with peptides containing a minimal number of exchangeable hydrogen atoms. The hydrogen atom model in ECD is indirectly supported by the proposed fragmentation mechanism for ISD, because our data suggest that hydrogen radicals can induce fragmentation by cleavage of the N-C(alpha) bond, independent from their origin.
A new technique for fragmentation of cations and anions of peptides stored in ion traps including radiofrequency devices is described. The technique involves irradiation of peptide ions by a beam of particles generated by a fast atom bombardment (FAB) gun. This irradiation leads to fragmentation of N--C(alpha) backbone bonds (c- and z-fragments) and S--S bonds for cations and C(alpha)-C backbone bonds (a- and x-fragments) for anions of peptides. The fragmentation patterns observed are hypothesized to be due to the interaction of peptide ions with metastable, electronically excited species generated by the FAB gun. Interaction of a metastable atom A* with a peptide n-cation M(n+) leads to the electron transfer from the metastable atom to the polycation through the formation of an ion-pair collision complex A(+.) . . . M((n-1)+.) and subsequent fragmentation of the peptide cation. Thus, for polycations, this metastable-induced dissociation of ions (MIDI) is similar to the phenomenon of electron capture dissociation (ECD). Interaction of A* with an anion leads to the deexcitation of the metastable species and detachment of an electron from the anion. This in turn leads to backbone fragmentation similar to that in electron detachment dissociation (EDD). The MIDI technique is robust and efficient, and it is applicable to peptides in as low charge states as 2+ or 2-.