Relationship between participant-reported outcomes, residual beta cell function and metabolic parameters in youth with newly diagnosed type 1 diabetes.

AIMS/HYPOTHESIS: Clinical trials of interventions to preserve beta cell function in new-onset type 1 diabetes frequently employ participant-reported outcome measures (PROMs). However, the expected changes in PROMs scores immediately following diagnosis and their association with residual beta cell function, metabolic markers and continuous glucose monitoring (CGM) are unclear. METHODS: Repeated PROMs including Paediatric Quality of Life Inventory diabetes module (PedsQL) and hypoglycaemia fear survey (HFS) were recorded from participants aged 10-18 years with newly diagnosed type 1 diabetes and their parents in two clinical trials: CLOuD (N=97, hybrid closed loop [HCL] vs multiple daily injections [MDI]) and USTEKID (N=72, ustekinumab immunotherapy vs placebo). Scores were compared with serial mixed meal-stimulated C-peptide levels (AUC C-peptide), HbA1c and CGM data. RESULTS: PedsQL and HFS scores for children/adolescents and their parents showed wide variation between individuals but did not change substantially within individuals over the first 48 months from diagnosis. Baseline scores were highly predictive of scores at 12-48 months (p<0.001). PedsQL scores were higher (better) in those reported by children/adolescents than by their parents (p<0.01). In contrast, HFS scores were higher in parents than children (p<0.001), indicating more fear. Strong correlations were observed between child and parent scores (p<0.001). No significant improvement in these scores was detected following intervention (ustekinumab or HCL). Meta-analysis revealed modest but statistically significant associations between HbA1c and PedsQL (&#x3b2;(std)=-0.11; 95% CI -0.20, -0.03) and HFS (&#x3b2;(std)=0.11; 95% CI 0.00, 0.21), and between CGM time in range and PedsQL (&#x3b2;(std)=0.14; 95% CI 0.03, 0.26) but not HFS (&#x3b2;(std)=-0.05; 95% CI -0.16, 0.06). Beta cell function (AUC C-peptide) was strongly associated with HbA1c (&#x3b2;(std)=-0.29; 95% CI -0.39, -0.20) and CGM time in range (&#x3b2;(std)=0.41; 95% CI 0.30, 0.52). Higher beta cell function showed a trend towards better PedsQL (&#x3b2;(std)=0.11; 95% CI -0.03, 0.25) and lower HFS (&#x3b2;(std)=-0.05; 95% CI -0.17, 0.07) but this did not reach statistical significance. CONCLUSIONS/INTERPRETATION: PedsQL and HFS scores changed little during the first 48 months after diagnosis of type 1 diabetes. These scores showed modest but statistically significant associations with measures of glucose management (HbA1c and CGM time in range), whereas the relationships with residual beta cell function (C-peptide) were weaker and did not reach significance. The modest size of these effects suggests current PROMs capture only limited aspects of the clinical benefit associated with beta cell preservation. Future research should incorporate psychometric instruments that are specifically adapted for young people using modern diabetes technologies and undergoing disease-modifying therapy, to ensure outcomes are meaningfully represented in early-stage type 1 diabetes trials.

Adolescent↗

Evolution of the Artificial Pancreas: Components and Integration-CGMs, Insulin, and AP Systems.

The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.

Humans↗

Evaluation of nonlinear regression approaches to estimation of insulin sensitivity by the minimal model with reference to Bayesian hierarchical analysis.

Minimal model analysis of intravenous glucose tolerance test (IVGTT) glucose and insulin concentrations offers a validated approach to measuring insulin sensitivity, but model identification is not always successful. Improvements may be achieved by using alternative settings in the modeling process, although results may differ according to setting, and care must be exercised in combining results. IVGTT data (12 samples, regular test) from 533 men without diabetes was modeled by the traditional nonlinear regression (NLR) approach, using five different permutations of settings. Results were evaluated with reference to the more robust Bayesian hierarchical (BH) approach to model identification and to the proportion of variance they explained in known correlates of insulin sensitivity (age, BMI, blood pressure, fasting glucose and insulin, serum triglyceride, HDL cholesterol, and uric acid concentration). BH analysis was successful in all cases. With NLR analysis, between 17 and 35 IVGTTs were associated with parameter coefficients of variation (PCVs) for minimal model parameters S(I) (insulin sensitivity) and S(G) (glucose effectiveness) of >100%. Systematic use of each different approach in combination reduced this number to five. Mean (interquartile range) S(I)(NLR) was then 3.14 (2.29-4.63) min(-1).mU(-1).l x 10(-4) and 2.56 (1.74-3.83) min(-1).mU(-1).l x 10(-4) for S(I)(BH) (correlation 0.86, P < 0.0001). S(I)(NLR) explained, on average, 10.6% of the variance in known correlates of insulin sensitivity, whereas S(I)(BH) explained 8.5%. In a large body of data, which BH analysis demonstrated could be fully identified, use of alternative modeling settings in NLR analysis could substantially reduce the number of analyses with PCVs >100%. S(I)(NLR) compared favorably with S(I)(BH) in the proportion of variance explained in known correlates of insulin sensitivity.

Bayes Theorem↗

Mass kinetics of apolipoprotein A-I in interstitial fluid after administration of intravenous apolipoprotein A-I/lecithin discs in humans.

Apolipoprotein kinetics are customarily determined by modeling time curves of specific radioactivity or isotopic enrichment in plasma after intravenous infusion of radiolabeled lipoproteins or stable isotope-enriched amino acids. However, this provides no information on the fractional rate of transfer of the apolipoprotein from plasma to interstitial fluid (k(p-if)) or its mean residence time in interstitial fluid (MRT(if)). To determine these parameters for a pharmacologic dose of exogenous apolipoprotein A-I (apoA-I) given intravenously as apoA-I/lecithin discs, we measured apoA-I in plasma and prenodal leg lymph in five healthy men before, during, and after a 4 h infusion at 10 mg/kg/h. ApoA-I concentrations in plasma and lymph were modeled by linear compartmental models (SAAM II version 1.1), using lymph albumin to adjust for the effects of variations in lymph flow rate. k(p-if) averaged 0.75%/h (range, 0.33-1.32), and MRT(if) averaged 29.1 h (14.1-40.0). Neither parameter was correlated with the distribution volume (57-105 ml/kg) or the fractional elimination rate (1.44-2.91%/h) of apoA-I, determined by modeling plasma apoA-I concentration alone. Although used here to study the mass kinetics of apoA-I, if combined with infusion of a tracer, analysis of lymph could also expand the modeling of endogenous apolipoprotein kinetics.

Adult↗

Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients.

OBJECTIVE: To evaluate a fully automated algorithm for the establishment of tight glycemic control in critically ill patients and to compare the results with different routine glucose management protocols of three intensive care units (ICUs) across Europe (Graz, Prague, and London). RESEARCH DESIGN AND METHODS: Sixty patients undergoing cardiac surgery (age 67 +/- 9 years, BMI 27.7 +/- 4.9 kg/m2, 17 women) with postsurgery blood glucose levels >120 mg/dl (6.7 mmol/l) were investigated in three different ICUs (20 per center). Patients were randomized to either blood glucose management (target range 80-110 mg/dl [4.4-6.1 mmol/l]) by the fully automated model predictive control (MPC) algorithm (n = 30, 10 per center) or implemented routine glucose management protocols (n = 30, 10 per center). In all patients, arterial glucose was measured hourly to describe the glucose profile until the end of the ICU stay but for a maximum period of 48 h. RESULTS: Compared with routine protocols, MPC treatment resulted in a significantly higher percentage of time within the target glycemic range (% median [min-max]: 52 [17-92] vs. 19 [0-71]) over 0-24 h (P < 0.01). Improved glycemic control with MPC treatment was confirmed in patients remaining in the ICU for 48 h (0-24 h: 50 [17-71] vs. 21 [4-67], P < 0.05, and 24-48 h: 65 [38-96] vs. 25 [8-79], P < 0.05, for MPC [n = 16] vs. routine protocol [n = 13], respectively). Two hypoglycemic events (<54 mg/dl [3.0 mmol/l]) were observed with routine protocol treatment. No hypoglycemic event occurred with MPC. CONCLUSIONS: The data suggest that the MPC algorithm is safe and effective in controlling glycemia in critically ill postsurgery patients.

Aged↗

Grading system to assess clinical performance of closed-loop glucose control.

Closed-loop control of the glucose concentration in type 1 diabetes has been the subject of extensive research over the last 3 decades. Building on the recent progress in continuous glucose sensing techniques, several prototypes of a closed-loop system have been developed. To complement existing measures of glucose control, we designed a grading system specifically designed to provide clinical assessment of closed-loop systems including that of glucose controllers. The system introduces six grades, A-F, describing the level of control and the therapeutic intervention during outside-meal and postprandial conditions. Grades A and B represent excellent and good glucose control, respectively, without the need for a corrective therapeutic action. Grade C represents suboptimal control with a recommendation for a corrective action. Grade D represents poor control requiring a corrective action. Grades E and F represent very poor and life-threatening control, respectively, with a need for an immediate corrective action or requiring external assistance. The outcome of grading is the quantification of time spent in each grade. The grading system is exemplified using data obtained with a model predictive controller within an in silico simulation environment. We conclude that the grading system provides suitable means to assess efficacy and safety of glucose controllers complementing existing measures of glucose control.

Algorithms↗

Insulin kinetics in type-I diabetes: continuous and bolus delivery of rapid acting insulin.

We investigated insulin lispro kinetics with bolus and continuous subcutaneous insulin infusion (CSII) modes of insulin delivery. Seven subjects with type-1 diabetes treated by CSII with insulin lispro have been studied during prandial and postprandial conditions over 12 hours. Eleven alternative models of insulin kinetics have been proposed implementing a number of putative characteristics. We assessed 1) the effect of insulin delivery mode, i.e., bolus or basal, on the insulin absorption rate, the effects of 2) insulin association state and 3) insulin dose on the rate of insulin absorption, 4) the remote insulin effect on its volume of distribution, 5) the effect of insulin dose on insulin disappearance, 6) the presence of insulin degradation at the injection site, and finally 7) the existence of two pathways, fast and slow, of insulin absorption. An iterative two-stage parameter estimation technique was used. Models were validated through assessing physiological feasibility of parameter estimates, posterior identifiability, and distribution of residuals. Based on the principle of parsimony, best model to fit our data combined the slow and fast absorption channels and included local insulin degradation. The model estimated that 67(53-82)% [mean (interquartile range)] of delivered insulin passed through the slow absorption channel [absorption rate 0.011(0.004-0.029) min(-1)] with the remaining 33% passed through the fast channel [absorption rate 0.021(0.011-0.040) min(-1)]. Local degradation rate was described as a saturable process with Michaelis-Menten characteristics [VMAX = 1.93(0.62 - 6.03) mU min(-1), KM = 62.6(62.6 - 62.6) mU]. Models representing the dependence of insulin absorption rate on insulin disappearance and the remote insulin effect on its volume of distribution could not be validated suggesting that these effects are not present or cannot be detected during physiological conditions.

Adult↗

Evaluation of glucose controllers in virtual environment: methodology and sample application.

OBJECTIVE: Adaptive systems to deliver medical treatment in humans are safety-critical systems and require particular care in both the testing and the evaluation phase, which are time-consuming, costly, and confounded by ethical issues. The objective of the present work is to develop a methodology to test glucose controllers of an artificial pancreas in a simulated (virtual) environment. MATERIAL AND METHODS: A virtual environment comprising a model of the carbohydrate metabolism and models of the insulin pump and the glucose sensor is employed to simulate individual glucose excursions in subjects with type 1 diabetes. The performance of the control algorithm within the virtual environment is evaluated by considering treatment and operational scenarios. RESULTS: The developed methodology includes two dimensions: testing in relation to specific life style conditions, i.e. fasting, post-prandial, and life style (metabolic) disturbances; and testing in relation to various operating conditions, i.e. expected operating conditions, adverse operating conditions, and system failure. We define safety and efficacy criteria and describe the measures to be taken prior to clinical testing. The use of the methodology is exemplified by tuning and evaluating a model predictive glucose controller being developed for a wearable artificial pancreas focused on fasting conditions. CONCLUSION: Our methodology to test glucose controllers in a virtual environment is instrumental in anticipating the results of real clinical tests for different physiological conditions and for different operating conditions. The thorough testing in the virtual environment reduces costs and speeds up the development process.

Algorithms↗

Population and individual minimal modeling of the frequently sampled insulin-modified intravenous glucose tolerance test.

Population approaches are more robust estimators of insulin sensitivity (SI) and glucose effectiveness (SG) with the minimal model of glucose kinetics during an intravenous glucose tolerance test (IVGTT). We assessed the performance of 3 population methods, iterative two-stage (ITS), Bayesian hierarchical Markov chain Monte Carlo (MCMC), and NONMEM first-order conditional estimation (FOCE) with interaction (NM), and made a comparison with the standard two-stage method (STS) employing the weighted nonlinear regression analysis. To evaluate accuracy of individual and population estimates, 40 simulated insulin-modified frequently sampled IVGTTs (IM-FSIVGTT) were derived from real IM-FSIVGTTs (0.3 g glucose per kg body weight with 0.02 U/kg insulin at 20 minutes; 30 samples over 180 minutes) performed in 40 healthy Caucasian subjects (male/female, 22/18; age, 46 +/- 9 years; body mass index [BMI], 26.7 +/- 5.7 kg. m(-2); mean +/- SD). The population methods assumed a log-normal population distribution of parameters. All methods gave a similar but overestimated population SG by 9% to 13%. Population SI was underestimated to a different degree by the methods (STS 6%, ITS 10%, MCMC 13%, and NM 7%). The between-subject variability of SG was overestimated by STS and underestimated by the population methods (true 33%, STS 40%, ITS 19%, MCMC 24%, NM 24%; coefficient of variation). For SI, this quantity was well estimated by all methods (true 79%, STS 80%, ITS 82%, MCMC 83%, NM 82%). The results for individual estimates indicate that STS performs better than the population methods when estimating SI (STS 12%, ITS 16%, MCMC 16%, NM 16%; 1 outlying subject excluded; root mean squared error expressed as percent of mean) but worse for SG (STS 28%, ITS 21%, MCMC 20%, NM 19%). We conclude that the robust performance of population approaches, preventing parameter estimation failures associated with the nonlinear regression analysis, is not required with IM-FSIVGTT in subjects with normal glucose tolerance. The standard two-stage technique is the preferred method under such circumstances.

Adult↗

Interstitial glucose kinetics in subjects with type 1 diabetes under physiologic conditions.

We investigated the dynamic relationship between interstitial glucose (IG) in the subcutaneous adipose tissue and plasma glucose (PG) during physiologic conditions in type 1 diabetes mellitus (T1DM). Nine subjects with T1DM (5/4 M/F; age, 33 +/- 13 years; body mass index, 26.6 +/- 4.3 kg/m(2); glycosylated hemoglobin [HbA(1c)], 8.6% +/- 0.9%; mean +/- SD) treated by continuous subcutaneous insulin infusion (CSII) with insulin lispro were studied over 12 hours after a standard meal (40 g carbohydrate [CHO]) and prandial insulin. IG was measured by open flow microperfusion. Nine compartment models were postulated to account for temporal variations in the IG/PG ratio. The models differed in the inclusion of physiologically motivated alterations of pathways entering/leaving the IG compartment in the adipose tissue. The best model included zero order (constant) glucose disposal from the interstitial fluid (ISF) and insulin-stimulated glucose transfer from plasma to the ISF. The former effect is expressed by a positive association between the IG/PG ratio and PG, eg, a decrease in PG from 9 to 3.3 mmol/L lowers the IG/PG ratio by 0.1. The latter effect results in the IG/PG ratio to be increased by 0.03 per 10 mU/L of plasma insulin. We were not able to detect the stimulatory effect of insulin on glucose disappearance from the ISF. In conclusion, we developed and quantified a model of IG kinetics in the adipose tissue applicable to physiologic conditions in subjects with T1DM.

Adipose Tissue↗

Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcutaneously administered short-acting insulin Lispro and gut absorption. The controller uses Bayesian parameter estimation to determine time-varying model parameters. Moving target trajectory facilitates slow, controlled normalization of elevated glucose levels and faster normalization of low glucose values. The predictive capabilities of the model have been evaluated using data from 15 clinical experiments in subjects with type 1 diabetes. The experiments employed intravenous glucose sampling (every 15 min) and subcutaneous infusion of insulin Lispro by insulin pump (modified also every 15 min). The model gave glucose predictions with a mean square error proportionally related to the prediction horizon with the value of 0.2 mmol L(-1) per 15 min. The assessment of clinical utility of model-based glucose predictions using Clarke error grid analysis gave 95% of values in zone A and the remaining 5% of values in zone B for glucose predictions up to 60 min (n = 1674). In conclusion, adaptive nonlinear model predictive control is promising for the control of glucose concentration during fasting conditions in subjects with type 1 diabetes.

Blood Glucose↗

Closing the loop: the adicol experience.

The objective of the project Advanced Insulin Infusion using a Control Loop (ADICOL) was to develop a treatment system that continuously measures and controls the glucose concentration in subjects with type 1 diabetes. The modular concept of the ADICOL's extracorporeal artificial pancreas consisted of a minimally invasive subcutaneous glucose system, a handheld PocketPC computer, and an insulin pump (D-Tron, Disetronic, Burgdorf, Switzerland) delivering subcutaneously insulin lispro. The present paper describes a subset of ADICOL activities focusing on the development of a glucose controller for semi-closed-loop control, an in silico testing environment, clinical testing, and system integration. An incremental approach was adopted to evaluate experimentally a model predictive glucose controller. A feasibility study was followed by efficacy studies of increasing complexity. The ADICOL project demonstrated feasibility of a semi-closed-loop glucose control during fasting and fed conditions with a wearable, modular extracorporeal artificial pancreas.

Blood Glucose↗

Bayesian hierarchical approach to estimate insulin sensitivity by minimal model.

We adopted Bayesian analysis in combination with hierarchical (population) modelling to estimate simultaneously population and individual insulin sensitivity (SI) and glucose effectiveness (SG) with the minimal model of glucose kinetics using data collected during insulin-modified intravenous glucose tolerance test (IVGTT) and made comparison with the standard non-linear regression analysis. After fasting overnight, subjects with newly presenting Type II diabetes according to World Health Organization criteria (n =65; 53 males, 12 females; age, 54 +/- 9 years; body mass index, 30.4 +/- 5.2 kg/m2; means+/-S.D.) underwent IVGTT consisting of a 0.3 g of glucose bolus/kg of body weight given at time zero for 2 min, followed by 0.05 unit of insulin/kg of body weight at 20 min. Bayesian inference was carried out using vague prior distributions and log-normal distributions to guarantee non-negativity and, thus, physiological plausibility of model parameters and associated credible intervals. Bayesian analysis gave estimates of SI in all subjects. Non-linear regression analysis failed in four cases, where Bayesian analysis-derived SI was located in the lower quartile and was estimated with lower precision. The population means of SI and SG provided by Bayesian analysis and non-linear regression were identical, but the interquartile range given by Bayesian analysis was tighter by approx. 20% for SI and by approx. 15% for SG. Individual insulin sensitivities estimated by the two methods were highly correlated ( rS=0.98; P <0.001). However, the correlation in the lower 20% centile of the insulin-sensitivity range was significantly lower than the correlation in the upper 80% centile ( rS=0.71 compared with rS=0.99; P <0.001). We conclude that the Bayesian hierarchical analysis is an appealing method to estimate SI and SG, as it avoids parameter estimation failures, and should be considered when investigating insulin-resistant subjects.

Adult↗

Partitioning glucose distribution/transport, disposal, and endogenous production during IVGTT.

We have separated the effect of insulin on glucose distribution/transport, glucose disposal, and endogenous production (EGP) during an intravenous glucose tolerance test (IVGTT) by use of a dual-tracer dilution methodology. Six healthy lean male subjects (age 33 +/- 3 yr, body mass index 22.7 +/- 0.6 kg/m(2)) underwent a 4-h IVGTT (0.3 g/kg glucose enriched with 3-6% D-[U-(13)C]glucose and 5-10% 3-O-methyl-D-glucose) preceded by a 2-h investigation under basal conditions (5 mg/kg of D-[U-(13)C]glucose and 8 mg/kg of 3-O-methyl-D-glucose). A new model described the kinetics of the two glucose tracers and native glucose with the use of a two-compartment structure for glucose and a one-compartment structure for insulin effects. Insulin sensitivities of distribution/transport, disposal, and EGP were similar (11.5 +/- 3.8 vs. 10.4 +/- 3.9 vs. 11.1 +/- 2.7 x 10(-2) ml small middle dot kg(-1) small middle dot min(-1) per mU/l; P = nonsignificant, ANOVA). When expressed in terms of ability to lower glucose concentration, stimulation of disposal and stimulation of distribution/transport accounted each independently for 25 and 30%, respectively, of the overall effect. Suppression of EGP was more effective (P < 0.01, ANOVA) and accounted for 50% of the overall effect. EGP was suppressed by 70% (52-82%) (95% confidence interval relative to basal) within 60 min of the IVGTT; glucose distribution/transport was least responsive to insulin and was maximally activated by 62% (34-96%) above basal at 80 min compared with maximum 279% (116-565%) activation of glucose disposal at 20 min. The deactivation of glucose distribution/transport was slower than that of glucose disposal and EGP (P < 0.02) with half-times of 207 (84-510), 12 (7-22), and 29 (16-54) min, respectively. The minimal-model insulin sensitivity was tightly correlated with and linearly related to sensitivity of EGP (r = 0.96, P < 0.005) and correlated positively but nonsignificantly with distribution/transport sensitivity (r = 0.73, P = 0.10) and disposal sensitivity (r = 0.55, P = 0.26). We conclude that, in healthy subjects during an IVGTT, the two peripheral insulin effects account jointly for approximately one-half of the overall insulin-stimulated glucose lowering, each effect contributing equally. Suppression of EGP matches the effect in the periphery.

3-O-Methylglucose↗

Associations of glucose control with insulin sensitivity and pancreatic beta-cell responsiveness in newly presenting type 2 diabetes.

We examined the ability of indices of insulin sensitivity and pancreatic beta-cell responsiveness to explain interindividual variability of clinical measures of glucose control in newly presenting type 2 diabetes. Subjects with newly presenting type 2 diabetes (n = 65; 53 males and 12 females; age, 54 +/- 1 yr; body mass index, 30.5 +/- 0.7 kg/m(2); mean +/- SE) underwent an insulin-modified iv glucose tolerance test to determine minimal model-derived insulin sensitivity (S(I)), glucose effectiveness, first-phase insulin secretion, and disposition index. Subjects also underwent a standard meal tolerance test (MTT) to measure fasting/basal (M(0)) and postprandial (M(I)) pancreatic beta-cell responsiveness. Stepwise linear regression used these indices to explain interindividual variability of fasting and postprandial plasma glucose and insulin concentrations and glycated hemoglobin (HbA(1C)). All measures of pancreatic beta-cell responsiveness (M(0), M(I), and first-phase insulin secretion) were negatively correlated with fasting plasma glucose (P < 0.01) and positively correlated with fasting plasma insulin (FPI) and insulin responses to MTT (P < 0.05). S(I) demonstrated negative correlation with FPI (P < 0.001) but failed to correlate with any glucose variable. M(I) followed by disposition index (composite index of insulin sensitivity and pancreatic beta-cell responsiveness) were most informative in explaining interindividual variability. It was possible to explain 70-80% interindividual variability of fasting plasma glucose, FPI, HbA(1C), and insulin responses to MTT, and only 25-40% interindividual variability of postprandial glucose. In conclusion, postprandial insulin deficiency is the most powerful explanatory factor of deteriorating glucose control in newly presenting type 2 diabetes. Indices of insulin sensitivity and pancreatic beta-cell responsiveness explain fasting glucose and HbA(1C) well but fail to explain postprandial glucose.

Blood Glucose↗