High efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable. Kinetic plots and experimental verification.

Theoretical aspects of temperature in liquid chromatography (LC) have mostly been studied to elucidate changes in retention behavior of small and large molecules in various solvents. That temperature also plays a significant role in chromatographic performance is less known. Kinetic plots are an established tool to predict chromatographic performance in terms of speed and efficiency that can be obtained with a certain particle size at the maximum attainable column pressure. In this paper, temperature effects on mobile phase viscosity and analyte diffusion are incorporated in these plots to prove that superior performances are within experimental reach for conventional LC columns and equipment. Verification of the modified kinetic plots with experimental data points is presented.

Chromatography, Liquid↗

Evaluation of ultra performance liquid chromatography. Part I. Possibilities and limitations.

A practical evaluation of the possibilities and limitations of ultra performance liquid chromatography (UPLC) is presented. Acquity BEH columns packed with 1.7 microm particles are evaluated by means of van Deemter and Knox plots. The columns are characterised by high optimal velocities (3.7 mm/s) and low plate heights (4.4 microm). Minimum plate heights of 2d(p) were, however, not reached and reasons are presented and discussed. Furthermore, the use of 1.7 microm particles at 1000 bar is compared, from a theoretical viewpoint, to conventional LC (3.5 and 5 microm particles at 400 bar) in terms of analysis speed and practical maximum efficiency. Experimental data are used to construct kinetic- or "Poppe-plots", which facilitate investigation of the effect of pressure and particle size on speed and efficiency. It is found that UPLC conditions hold advantages in terms of speed of analysis, for required theoretical plate counts up to approximately 80,000.

Acetophenones↗

Universal response in liquid chromatography using charged aerosol detection.

A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-microL injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.

Aerosols↗

Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns.

The effects of viscous heat dissipation on some important HPLC parameters, such as efficiency (N) and retention factors (k), using 2.1mm columns at pressures up to 1000 bar have been investigated from both a theoretical and experimental point of view. Two distinct experimental set-ups and their respective influences on non-homogenous temperature gradients within the column are described and discussed. In the first instance, a still-air column heater was used. This set-up leads to approximate 'adiabatic' conditions, and a longitudinal temperature gradient is predicted across the length of the column. The magnitude of this gradient is calculated, and its occurrence confirmed with experimental measurements also indicating that no appreciable loss in efficiency occurs. Secondly, when a water bath is used to thermostat the column, a radial temperature gradient is prevalent. The extent of this gradient is estimated, and the loss in efficiency associated with this gradient is predicted and demonstrated experimentally. It is also observed that approximate adiabatic conditions can lead to floating retention factors. The implications of temperature gradients for routine HPLC analysis at ultra-high pressure are discussed.

Chromatography, High Pressure Liquid↗

High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable I. Experiments with 25 cm x 4.6 mm I.D., 5 microm ODS columns.

High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.

Chromatography, Liquid↗

A generic approach to the impurity profiling of drugs using standardised and independent capillary zone electrophoresis methods coupled to electrospray ionisation mass spectrometry.

Three standardised, capillary zone electrophoresis-electrospray ionisation mass spectrometry (CZE-ESI-MS) methods were developed for the analysis of six drug candidates and their respective process-related impurities comprising a total of 22 analytes with a range of functional groups and lipophilicities. The selected background electrolyte conditions were found to be: 60/40 v/v 10 mM ammonium formate pH 3.5/organic, 60/40 v/v 10 mM ammonium acetate pH 7.0/organic and 10 mM piperidine, pH 10.5, where the organic solvent is 50/50 v/v methanol/acetonitrile. The coaxial sheath flow consisted of either 0.1% v/v formic acid in 50/50 v/v methanol/water, or 10 mM ammonium acetate in 50/50 v/v methanol/water, depending on the mixture being analysed. Factor analysis and informational theory were used to quantify the orthogonality of the methods and predict their complementarities. The three selected CZE-ESI-MS methods allowed the identification of 21 out of 22 of all the drug candidates and their process-related impurities and provided orthogonality with four established high-performance liquid chromatography-mass spectrometry (HPLC-MS) methods. These methodologies therefore form the basis of a generic approach to impurity profiling of pharmaceutical drug candidates and can be applied with little or no analytical method development, thereby offering significant resource and time savings.

Drug Contamination↗