Effect of artificial lung compliance on in vivo pulmonary system hemodynamics.

This study examined the effect of artificial lung compliance (C) on pulmonary system (PS) impedance and right ventricular function during in-series attachment of the MC3 Biolung in adult sheep. Compliances, C, of 0-20 ml/mm Hg were tested at the Biolung inlet. Results indicate the PS 0 harmonic input impedance modulus was not affected by C. The PS first harmonic input impedance modulus (Z1) was 10.9 +/- 3.2 mm Hg/(l/min) at C = 0 ml/mm Hg and minimized to 2.41 +/- 0.79 mm Hg/(l/min) at C > or = 0.5 ml/mm Hg. Cardiac output was 58% +/- 10% of its pre-Biolung attachment, baseline value at C = 0 ml/mm Hg and was maximized to an average of 75% +/- 11% at C > or = 0.5 ml/mm Hg. The left ventricular lateral-to-anteroposterior axis length ratio, which decreases with leftward septal shift, increased with C from 0.52 +/- 0.12 at C = 0 ml/mm Hg to 0.76 +/- 0.06 at C = 5 ml/mm Hg (p < 0.05), but decreased slightly with C at C > 5 ml/mm Hg. Therefore, the ideal C for right ventricular function is at least 0.5 ml/mm Hg and may be as high as 5 ml/mm Hg to minimize septal shift.

Animals↗

Pulsatile flow past a cylinder: an experimental model of flow in an artificial lung.

The focus of this study is an experimental apparatus that serves as a model for studying blood flow in a total artificial lung (TAL), a prototype device intended to serve as a bridge to lung transplantation or that supports pulmonary function during the treatment of severe respiratory failure. The TAL consists of hollow cylindrical fibers that oxygen-rich air flows through and oxygen-poor blood flows around. Because gas diffusivity in the TAL is very small, a convection mechanism dominates the gas transport, which is why we focus on the velocity around the fibers (modeled as a 0.05-cm-in-diameter and 5-cm-long cylinder). We designed a low-speed water tunnel to study the flow mechanism around the cylinder, across which the flow is generated by a linear actuator that allows different flow patterns to mimic the flow in a TAL. We tested the flow in the test section by numerical simulation and by the particle image velocimetry method to study the flow profile. The results show a uniform flow near the centerline of the water tunnel where the cylinder is placed. This decreases the effects of free-stream turbulence in the shear layers and reduces the uncertainty in determining the flow patterns around the cylinder. Knowledge gained from the flow around one cylinder (fiber) is beneficial for understanding vortex formation around multiple cylinders. We present a summary of vortex formation behind a cylinder for Reynolds numbers (Re) of 1, 3, and 5 and Stokes numbers (Ns) of 0.18 to 0.37; results show that higher Re and Ns favor vortex formation. These findings regarding the parameter range for vortex formation may provide principles for designing artificial lungs to enhance convective mixing. We anticipate that the pulsatile flow circuit presented here can be used to mimic the flow not only in TALs but in other physiological systems.

Animals↗

Parenteral nutrition-associated cholestasis in neonates: multivariate analysis of the potential protective effect of taurine.

BACKGROUND: Neonates receiving parenteral nutrition (PN) are at risk for PN-associated cholestasis (PNAC); however, no preventive factors for PNAC have been clearly identified. Despite reports suggesting that taurine may prevent PNAC in neonates, such an effect of taurine has not yet been definitively demonstrated. We determined whether taurine supplementation reduces the incidence of PNAC in premature or critically ill neonates. METHODS: This study was part of a prospective, randomized, multi-institutional trial designed to assess cholecystokinin vs placebo as a potential preventive therapy of PNAC. Taurine supplementation of PN varied between institutions. The presence or absence of taurine in PN was analyzed by multivariate analysis, with a primary outcome measure of serum conjugated bilirubin (CB) as a measure of PNAC. RESULTS: Taurine reduced PNAC in premature infants (estimated maximum CB [95% confidence interval] 0.50 mg/dL [-0.17 to 1.18] for those receiving taurine, vs 3.45 mg/dL [1.79-5.11] for neonates not receiving taurine, approaching significance, p = .07). Taurine significantly reduced PNAC in infants with necrotizing enterocolitis (NEC; estimated maximum CB 4.04 mg/dL [2.85-5.23], NEC infants receiving taurine, vs 8.29 mg/dL [5.61-10.96], NEC infants not receiving taurine, p < .01). There were too few neonates with surgical anomalies to evaluate the effect of taurine in this group. CONCLUSIONS: Within specific subgroups of neonatal patients, taurine supplementation does offer a very significant degree of protection against PNAC. Patients with NEC or severe prematurity are most likely to benefit substantially from taurine supplementation.

Bilirubin↗

Flow vectorial analysis in an artificial implantable lung.

An artificial implantable lung would be a useful device to support patients awaiting lung transplantation. A suitable device must offer low resistance and adequate gas exchange, be impermeable to plasma, and nonthrombogenic. Although plasma permeability is an intrinsic quality of the materials, the other requirements are largely a function of device geometry, particularly as it relates to fluid dynamics. Using a CAD system and the requirements of a membrane surface area of 1.5 m2 and an inlet outlet port distance of 12 cm, we designed 10 models that varied in their other dimensions. Computational fluid dynamic (CFD) software was applied to the models to determine which minimized regions of low flow velocity. A prototype built to these specifications was used in an in vivo ovine experiment to verify the CFD predictions. The prototype was placed in parallel to the native pulmonary circulation (pulmonary artery to left atrium) for 120 minutes while the activated coagulation times were kept between 110 and 120 seconds and device flow was maintained between 1.5 and 2.5 L/min. Examination of the prototype confirmed a correlation between predicted areas of low flow and thrombus formation. Although nearly identical low flow velocity conditions exist at both the inlet and outlet ports, thrombus formation occurs only near the outlet port. This finding agrees with detailed vectorial analysis, which predicts a more complex flow pattern near the outlet port. Although near the inlet port flow vectors are nearly parallel, near the outlet port flow vectors collide. This area of flow collision corresponds to the area of thrombus formation in vivo. The addition of microflow vectorial analysis to flow velocity predictions allows for improved accuracy in predicting regions at risk of thrombosis in an artificial implantable lung.

Animals↗