Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla.

BACKGROUND: Magnetic resonance imaging (MRI) is an important diagnostic modality currently unavailable for millions of patients because of the presence of implantable cardiac devices. We sought to evaluate the diagnostic utility and safety of noncardiac and cardiac MRI at 1.5T using a protocol that incorporates device selection and programming and limits the estimated specific absorption rate of MRI sequences. METHODS AND RESULTS: Patients with no imaging alternative and with devices shown to be MRI safe by in vitro phantom and in vivo animal testing were enrolled. Of 55 patients who underwent 68 MRI studies, 31 had a pacemaker, and 24 had an implantable defibrillator. Pacing mode was changed to "asynchronous" for pacemaker-dependent patients and to "demand" for others. Magnet response and tachyarrhythmia functions were disabled. Blood pressure, ECG, oximetry, and symptoms were monitored. Efforts were made to limit the system-estimated whole-body average specific absorption rate to 2.0 W/kg (successful in >99% of sequences) while maintaining the diagnostic capability of MRI. No episodes of inappropriate inhibition or activation of pacing were observed. There were no significant differences between baseline and immediate or long-term (median 99 days after MRI) sensing amplitudes, lead impedances, or pacing thresholds. Diagnostic questions were answered in 100% of nonthoracic and 93% of thoracic studies. Clinical findings included diagnosis of vascular abnormalities (9 patients), diagnosis or staging of malignancy (9 patients), and assessment of cardiac viability (13 patients). CONCLUSIONS: Given appropriate precautions, noncardiac and cardiac MRI can potentially be safely performed in patients with selected implantable pacemaker and defibrillator systems.

Artifacts↗

Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?

BACKGROUND: Ventricular tachyarrhythmias long enough to cause implantable cardioverter defibrillator (ICD) shocks are generally thought to progress to cardiac arrest. In previous ICD trials, shocks have been considered an appropriate surrogate for sudden cardiac death (SCD) because the number of shocks has been thought to be equivalent to the mortality excess in patients without ICDs. The practice of equating ICD shocks with mortality is controversial and has not been validated critically. METHODS AND RESULTS: The Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial was a prospective, randomized, multicenter trial of ICD therapy in 458 patients with nonischemic cardiomyopathy. Patients were randomized to receive standard medical therapy (STD) or STD plus an ICD. Shock electrograms were reviewed, and the cause of death was evaluated by a separate blinded events committee. There were 15 SCD or cardiac arrests in the STD group and only 3 in the ICD arm. In contrast, of the 229 patients randomized to an ICD, 33 received 70 appropriate ICD shocks. Patients in the ICD arm were more likely to have an arrhythmic event (ICD shock plus SCD) than patients in the STD arm (hazard ratio 2.12, 95% CI 1.153 to 3.893, P=0.013). The number of arrhythmic events when one includes syncope as a potential arrhythmic event was similar in both groups (hazard ratio 1.20, 95% CI 0.774 to 1.865, P=0.414). Approximately the same number of total events was noted in each arm when we compared syncope plus SCD/cardiac arrest in the STD arm with SCD plus ICD shocks plus syncope in the ICD arm. CONCLUSIONS: Appropriate ICD shocks occur more frequently than SCD in patients with nonischemic cardiomyopathy. This suggests that episodes of nonsustained ventricular tachycardia frequently terminate spontaneously in such patients.

Aged↗

Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations.

BACKGROUND: New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time. METHODS AND RESULTS: After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9+/-0.9 mm for the right atrium, 2.7+/-1.2 mm for the right ventricle, 1.8+/-1.0 mm for the left atrium, and 2.3+/-1.1 mm for the left ventricle. To evaluate the system's guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8+/-1.5, 2.2+/-1.3, and 2.1+/-1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers. CONCLUSIONS: Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.

Animals↗

Imaging of myocardial dyssynchrony in congestive heart failure.

Heart failure constitutes a major health problem in USA and Europe. Angiotensin converting enzyme inhibitors and _ blockers were shown to reduce morbidity and mortality in patients with CHF. Yet, their effectiveness is limited. A significant number of patients with heart failure manifest myocardial conduction abnormalities. Conduction abnormalities, especially in the form of left bundle branch block (LBBB) may be associated with abnormal mechanical function. Several studies demonstrated that these patients may gain benefit from biventricular (BiV) pacing in terms of improvement in exercise tolerance, heart failure morbidity and even decreased mortality. BiV pacing was also associated with improvement in ejection fraction, reduction in the extent of mitral regurgitation and a decrease in cardiac size (reverse remodeling). However, a significant number of patients do not gain benefit from biventricular pacing despite having conduction abnormalities. The underlying reason is that the electrical activity may not closely reflect mechanical activity. Several imaging modalities and techniques have been proposed to improve the selection of patients who may benefit from biventricular pacemakers. Of those, echo-Doppler, and especially, Tissue Doppler Imaging has been demonstrated as important tools for evaluating patients for cardiac resynchronization therapy (CRT) and following their response. The advantages of echo include accessibility, portability, its cost and a high temporal resolution. Yet, it is limited by its acoustic windows and scanning angles. MRI is a useful tool for evaluating patients for CRT by providing 3-D image of myocardial function. However, it is limited for follow-up after implantation due to its cost and a potential damage to the patients or pacemakers. Dyssnchrony imaging is a rapidly evolving field. New imaging techniques such as speckle tracking are promising and close update is needed to keep track of the developments and the changes in this exciting field.

Bundle-Branch Block↗

The benefit of upgrading chronically right ventricle-paced heart failure patients to resynchronization therapy demonstrated by strain rate imaging.

BACKGROUND: RV pacing induces conduction delay (CD), mechanical dyssynchrony, and increased morbidity in patients with HF. CRT improves HF symptoms and survival, but sparse data exist on its direct effect on chronically RV-paced HF patients. OBJECTIVES: To assess the benefit of cardiac resynchronization therapy (CRT) in chronically right ventricle (RV)-paced heart failure (HF) patients. METHODS: We studied 12 consecutive patients with class III HF who had a previously implanted pacemaker or implantable cardioverter-defibrillator. These individuals were chronically RV paced and referred for upgrade to a biventricular device by their primary cardiologists. Tissue Doppler and strain rate imaging (TDI and SRI, respectively) were performed immediately before each upgrade and 4-6 weeks afterward to quantify changes in regional wall motion and synchrony with CRT. RESULTS: CRT significantly reduced the mean QRS duration (205 ms to 156 ms; P<.0001), and it increased the ejection fraction (30.7%+/-5.1% to 35.8%+/-5.1%; P<.01). Left ventricular end-systolic and end-diastolic dimensions were also significantly reduced. Clinically, patients improved by an average of one New York Heart Association (NYHA) functional class after upgrade (P = .006). The parameter exhibiting greatest improvement was the coefficient of variation (CoV: standard deviation/mean) of time to peak systolic strain rate, a marker of ventricular dyssynchrony, which decreased from 34.3%+/-13.0% to 19.0%+/-6.6% (P<.01). Reduction in CoV of time to peak systolic strain rate was maximally seen in the midventricle (38.2%+/-19.6% to 16.5%+/-9.7%; P<.01). CONCLUSIONS: Upgrading chronically RV-paced HF patients to CRT improves global and regional systolic function. TDI and SRI provide compelling evidence that this benefit parallels that seen in HF patients with CD unrelated to RV pacing, which implies that biventricular pacing synchronizes mechanical activation in different myocardial regions in patients upgraded from RV pacing as well.

Aged↗

Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation.

INTRODUCTION: No prior studies have reported the use of integrated electroanatomic mapping with preacquired magnetic resonance/computed tomographic (MR/CT) images to guide catheter ablation of atrial fibrillation (AF) in a series of patients. METHODS AND RESULTS: Sixteen consecutive patients with drug-refractory AF underwent catheter ablation under the guidance of a three-dimensional (3D) electroanatomic mapping system (Carto, Biosense Webster, Inc., Diamond Bar, CA, USA). Gadolinium-enhanced MR (n = 8) or contrast-enhanced high-resolution CT (n = 8) imaging was performed within 1 day prior to the ablation procedures. Using a novel software package (CartoMerge, Biosense Webster, Inc.), the left atrium (LA) with pulmonary veins (PVs) was segmented and extracted for image registration. The segmented 3D MR/CT LA reconstruction was accurately registered to the real-time mapping space with a combination of landmark registration and surface registration. The registered 3D MR/CT LA reconstruction was successfully used to guide deployment of RF applications encircling the PVs. Upon completion of the circumferential lesions around the PVs, 32% of the PVs were electrically isolated. Guided by a circular mapping catheter, the remaining PVs were disconnected from the LA using a segmental approach. The distance between the surface of the registered 3D MR/CT LA reconstruction and multiple electroanatomic map points was 3.05 +/- 0.41 mm. No complications were observed. CONCLUSIONS: Three-dimensional MR/CT images can be successfully extracted and registered to anatomically guided clinical AF ablations. The display of detailed and accurate anatomic information during the procedure enables tailored RF ablation to individual PV and LA anatomy.

Atrial Fibrillation↗

The Rhythm ID Going Head to Head Trial (RIGHT): design of a randomized trial comparing competitive rhythm discrimination algorithms in implantable cardioverter defibrillators.

BACKGROUND: The implantable cardioverter defibrillator (ICD) has become primary therapy for the prevention of sudden death. One of the major morbidities of ICD use remains inappropriate therapy for supraventricular arrhythmias (SVA). Detection enhancements have increased therapy specificity, but their impact on inappropriate therapy is not well studied. Moreover, ICD manufacturers have developed unique algorithms to meet this goal, with no previous clinical direct comparisons. RIGHT is a randomized, prospective study that will assess the differential efficacy of ICDs from two different manufacturers. It is the first trial to compare directly competitive ICD rhythm discrimination algorithms on a large scale. OBJECTIVE: The primary objective of this study is to assess arrhythmia discrimination in Guidant versus Medtronic ICDs by comparing the time to first inappropriate therapy after the predischarge visit. METHODS: The study will enroll approximately 2,000 patients in 100 centers. Patients will be randomized to Guidant or Medtronic using a permuted block design, stratified by center and by single/dual chamber device types. Patients will receive a commercially available Guidant VITALITY 2 family ICD with Rhythm ID or a Medtronic ICD using the Enhanced PR Logic or Wavelet discrimination algorithms, and will be followed according to the schedule shown until a common closing date with a minimum follow-up of 12 months. All events will be reviewed by an independent committee to determine the appropriateness of rhythm classification and therapy delivery. CONCLUSION: RIGHT is the first randomized, large scale, head-to-head comparison of ICD discrimination algorithms.

Algorithms↗

Magnetic resonance assessment of the substrate for inducible ventricular tachycardia in nonischemic cardiomyopathy.

BACKGROUND: Patients with left ventricular dysfunction have an elevated risk of sudden cardiac death. However, the substrate for ventricular arrhythmia in patients with nonischemic cardiomyopathy remains poorly understood. We hypothesized that the distribution of scar identified by MRI is predictive of inducible ventricular tachycardia. METHODS AND RESULTS: Short-axis cine steady-state free-precession and postcontrast inversion-recovery gradient-echo MRI sequences were obtained before electrophysiological study in 26 patients with nonischemic cardiomyopathy. Left ventricular ejection fraction was measured from end-diastolic and end-systolic cine images. The transmural extent of scar as a percentage of wall thickness (percent scar transmurality) in each of 12 radial sectors per slice was calculated in all myocardial slices. The percentages of sectors with 1% to 25%, 26% to 50%, 51% to 75%, and 76% to 100% scar transmurality were determined for each patient. Predominance of scar distribution involving 26% to 75% of wall thickness was significantly predictive of inducible ventricular tachycardia and remained independently predictive in the multivariable model after adjustment for left ventricular ejection fraction (odds ratio, 9.125; P=0.020). CONCLUSIONS: MR assessment of scar distribution can identify the substrate for inducible ventricular tachycardia and may identify high-risk patients with nonischemic cardiomyopathy currently missed by ejection fraction criteria.

Cardiomyopathies↗

Direct visualization of coronary sinus ostium and branches with a flexible steerable fiberoptic infrared endoscope.

BACKGROUND: Placement of electrophysiology catheters and pacing leads in the coronary sinus is challenging in some patients, particularly those with dilated cardiomyopathy. We hypothesized that cannulation of the coronary sinus and its branches can be facilitated by direct visualization. This study reports our experience with navigation into and within the coronary sinus in a closed-chest animal preparation, using a flexible steerable fiberoptic infrared endoscope that allows visualization through flowing blood. OBJECTIVES: The purpose of this study was to assess the feasibility of direct visualization of endocardial structures through infrared endoscopy. METHODS: Internal jugular venous access was obtained in 10 healthy mongrel dogs (weight 35-45 kg). The infrared endoscope (2900 fiber imaging bundle, wavelength 1,620 nm, frame rate 10-30/s, 320 x 256 pixels) was advanced to the coronary sinus ostium and branches by direct visualization of anatomic landmarks, such as the tricuspid valve and inferior vena cava. Localization was confirmed by fluoroscopy, contrast injection, and pathologic examination. RESULTS: Structures such as the tricuspid valve and inferior vena cava were visualized at distances of 1 to 2 cm, allowing successful coronary sinus identification and engagement in all 10 dogs. Coronary sinus branch images closely resembled pathologic findings. CONCLUSION: Direct visualization of the coronary sinus ostium and branches is possible through infrared endoscopy. This technique likely will facilitate coronary sinus engagement and navigation for pacing lead and catheter placement.

Angioscopy↗

Internal defibrillation with minimal skeletal muscle activation: a new paradigm toward painless defibrillation.

BACKGROUND: Shock-induced pain produces substantial morbidity in recipients of implantable cardioverter-defibrillators (ICDs). This pain likely derives from activation of skeletal muscle and associated nerves in the chest and abdomen. In an effort to develop a painless defibrillation system, we designed an electrode arrangement that incorporates a conductive sock placed around the heart to confine the electric shock field to cardiac tissue. OBJECTIVES: The purpose of this study was to test whether cardiac defibrillation could be achieved without skeletal muscle activation using a novel electrode system. METHODS: Eight adult mongrel dogs were studied. Force of skeletal muscle contraction was measured by strain gauges attached to the forelimbs during delivery of internal shocks ranging in energy from 0.1 to 31 J. Biphasic shocks were delivered (1) between a right ventricular coil and a subcutaneous dummy can (standard configuration), and (2) between a left ventricular coil and an epicardial electrode sock. Internal and external defibrillation thresholds (DFTs) were determined for each electrode configuration. RESULTS: Shock-induced muscle contraction force was significantly lower using the sock electrode than with standard ICD electrodes at every shock energy level tested (P < .0001). Internal DFT was similar between electrode configurations (sock electrode: 8.6 +/- 4.2 J; standard: 11.0 +/- 6.3 J, P = .4), but muscle contraction force at DFT was greatly reduced with the new electrode system (1.8 +/- 2.0 kg vs 10.6 +/- 2.1 kg, P < .0001). The sock electrode rendered external defibrillation impossible, however, even at 360 J. CONCLUSION: Skeletal muscle activation induced by ICD shocks can be greatly reduced using an electrode system that confines the electric shock field to the heart. Refinement of this strategy may allow for delivery of painless shocks by ICDs. Further development is needed to overcome implant complexity and the higher external DFT with this type of electrode system.

Animals↗

Direct imaging of transvenous radiofrequency cardiac ablation using a steerable fiberoptic infrared endoscope.

BACKGROUND: Direct imaging through blood has been achieved in vivo using fiberoptics and infrared wavelength technology. OBJECTIVES: The purpose of this study was to determine the feasibility of using a percutaneous, steerable, fiberoptic infrared endoscope to identify and characterize the electrode-tissue interface during transvenous cardiac ablation. METHODS: Infrared endoscopy was performed during 24 catheter ablation attempts in 10 mongrel dogs. Infrared imaging was performed through a transparent dome located at the tip of a 7Fr steerable endoscope using an imaging wavelength of 1,620 nm. Radiofrequency ablation was performed using a 4-mm-tip electrode catheter. Attempts were made to identify the electrode-endocardial interface at each ablation site and to characterize any signal changes during ablation. RESULTS: The electrode-tissue interface could be identified at 19 of the 24 ablation sites. Changes at the electrode-tissue interface were observed during ablation at 14 sites, which included a gradual increase in the tissue signal intensity at 12 sites. Small lucencies near the ablation electrode were observed at six sites. There was no interference during energy delivery. Endocardial features identified by endoscopy correlated with the postmortem appearance. CONCLUSION: Direct imaging of intracardiac structures and the electrode-tissue interface can be achieved through blood during transvenous catheter ablation with infrared endoscopy using a steerable, fiberoptic, infrared endoscopic catheter. Ablation lesion formation can be seen as a gradual increase in signal intensity. Fiberoptic infrared endoscopy appears to be a promising new tool for guiding catheter ablation.

Animals↗

Predictors of appropriate implantable defibrillator therapies in patients with arrhythmogenic right ventricular dysplasia.

BACKGROUND: Arrhythmogenic right ventricular dysplasia (ARVD) is an inherited cardiomyopathy characterized by ventricular arrhythmias and sudden cardiac death. The risk factors for sudden death and indications for implantable cardioverter-defibrillator (ICD) placement in patients with ARVD are not well defined. OBJECTIVES: The purpose of this study was to determine which clinical and electrophysiologic variables best predict appropriate ICD therapies in patients with ARVD. Particular attention focused on whether the ICD was implanted for primary or second prevention. METHODS: We enrolled 67 patients (mean age 36 +/- 14 years) with definite or probable ARVD who had undergone ICD placement. Appropriate ICD therapies were recorded, and Kaplan-Meier analysis was used to compare the event-free survival time between patients based upon the indication for ICD placement (primary vs secondary prevention), results of electrophysiologic testing, and whether the patient had probable or definite ARVD. RESULTS: Over a mean follow-up of 4.4 +/- 2.9 years, 40 (73%) of 55 patients who met task force criteria for ARVD and 4 (33%) of 12 patients with probable ARVD had appropriate ICD therapies for ventricular tachycardia/ventricular fibrillation (VT/VF; P = .027). Mean time to ICD therapy was 1.1 +/- 1.4 years. Eleven of 28 patients who received an ICD for primary prevention (39%) and 33 of 35 patients who received an ICD for secondary prevention (85%) experienced appropriate ICD therapies (P = .001). Electrophysiologic testing did not predict appropriate ICD interventions in patients who received an ICD for primary prevention. Fourteen patients (21%) received ICD therapy for life-threatening (VT/VF >240 bpm) arrhythmias. There was no difference in the incidence of life-threatening arrhythmias in the primary and secondary prevention groups (P = .29). CONCLUSION: Patients who meet task force criteria for ARVD are at high risk for sudden cardiac death and should undergo ICD placement for primary and secondary prevention, regardless of electrophysiologic testing results. Further research is needed to confirm that a low-risk subset of patients who may not require ICD placement can be identified.

Adolescent↗

Short-term effects of right-left heart sequential cardiac resynchronization in patients with heart failure, chronic atrial fibrillation, and atrioventricular nodal block.

BACKGROUND: Single-site ventricular pacing in patients with heart failure, atrial fibrillation, and severe atrioventricular (AV) nodal block risks the generation of discoordinate contraction. Whether altering the site of stimulation can offset this detrimental effect and what role sequential right ventricular-left ventricular (RV-LV) stimulation might play in such patients remain unknown. METHODS AND RESULTS: Nine subjects with heart failure (ejection fraction, 14% to 30%), atrial fibrillation, and AV block were studied by pressure-volume analysis. Ventricular stimulation was applied to the RV (apex and outflow tract), LV free wall, and biventricular (BiV) at 80 and 120 bpm. BiV improved systolic function more than either site alone (dP/dt(max), 810+/-83, 924+/-98, 983+/-102 mm Hg/s for RV, LV, BiV, respectively; P<0.05), although LV pacing was significantly better than RV pacing. However, only BiV improved diastolic function (isovolumic relaxation) over RV or LV alone. Similar results were obtained for both heart rates. RV pacing site did not alter the BiV effect, and concomitant stimulation of both RV sites did not improve function over each alone. Finally, varying RV-LV delay revealed optimal responses with simultaneous pacing. CONCLUSIONS: Simultaneous BiV pacing acutely enhances both systolic and diastolic function over single-site RV or LV pacing in congestive heart failure patients with atrial fibrillation and advanced AV block. Sequential RV-LV stimulation offers minimal benefit on average and should perhaps be considered only in targeted subsets such as nonresponding patients.

Aged↗

Temporal repolarization lability differences among genotyped patients with the long QT syndrome.

The investigators sought to test whether certain long QT syndrome (LQTS) mutations are associated with increased repolarization lability and whether repolarization lability (quantified by the QT variability index [QTVI]) is increased in patients with LQTS compared with controls. In 32 genotyped patients with LQTS type 1 (LQT1), 32 genotyped patients with LQTS type 2 (LQT2), and 32 controls, the QTVI was increased in patients with LQT2 (-0.973 +/- 0.394, p = 0.01 vs controls) and in patients with LQT1 with mutations other than KCNQ1-FIN (-0.942 +/- 0.264, p = 0.04 vs controls) but was similar between the KCNQ1-FIN group and controls.

Adult↗

Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

BACKGROUND: MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. METHODS AND RESULTS: We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes <0.5 degrees C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was <100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (n=18), and after 4 weeks, 3- to 4-hour MR scans were performed (n=15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (<12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (n=3) not subjected to MRI. CONCLUSIONS: These data suggest that certain modern pacemaker and ICD systems may indeed be MRI safe. This may have major clinical implications for current imaging practices.

Animals↗