Propagation of errors from the sensitivity image in list mode reconstruction.

List mode image reconstruction is attracting renewed attention. It eliminates the storage of empty sinogram bins. However, a single back projection of all LORs is still necessary for the pre-calculation of a sensitivity image. Since the detection sensitivity is dependent on the object attenuation and detector efficiency, it must be computed for each study. Exact computation of the sensitivity image can be a daunting task for modern scanners with huge numbers of LORs. Thus, some fast approximate calculation may be desirable. In this paper, we analyze the error propagation from the sensitivity image into the reconstructed image. The theoretical analysis is based on the fixed point condition of the list mode reconstruction. The nonnegativity constraint is modeled using the Kuhn-Tucker condition. With certain assumptions and the first-order Taylor series approximation, we derive a closed form expression for the error in the reconstructed image as a function of the error in the sensitivity image. The result shows that the error response is frequency-dependent and provides a simple expression for determining the required accuracy of the sensitivity image calculation. Computer simulations show that the theoretical results are in good agreement with the measured results.

Algorithms↗

Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: comparison to 201Tl.

UNLABELLED: The goals of this investigation were to assess the accuracy of (18)F-fluorodihydrorotenone ((18)F-FDHR) as a new deposited myocardial flow tracer and to compare the results to those for (201)Tl. METHODS: The kinetics of these flow tracers in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts were evaluated over a flow range encountered in patients. The 2 flow tracers plus a vascular reference tracer ((131)I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves with the multiple-indicator dilution technique and spectral analysis. RESULTS: The mean +/- SD initial extraction fractions for (18)F-FDHR (0.85 +/- 0.07) and (201)Tl (0.87 +/- 0.05) were not significantly different, although the initial extraction fraction for (18)F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction for (201)Tl did not. The washout of (201)Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than was the washout of (18)F-FDHR. Except for the initial extraction fraction, (18)F-FDHR retention was higher (P < 0.001) and less affected by flow (P < 0.05) than was (201)Tl retention. Reflecting its superior retention, the net uptake of (18)F-FDHR was better correlated with flow than was that of (201)Tl at both 1 and 15 min after tracer introduction (P < 0.0001 for both comparisons). CONCLUSION: The superior correlation of (18)F-FDHR uptake with flow indicates that it is a better flow tracer than (201)Tl in the isolated rabbit heart. Compared with the other currently available positron-emitting flow tracers ((82)Rb, (13)N-ammonia, and (15)O-water), (18)F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.

Animals↗

Flow heterogeneity following global no-flow ischemia in isolated rabbit heart.

The purpose of this study was to evaluate flow heterogeneity and impaired reflow during reperfusion after 60-min global no-flow ischemia in the isolated rabbit heart. Radiolabeled microspheres were used to measure relative flow in small left ventricular (LV) segments in five ischemia + reperfused hearts and in five nonischemic controls. Relative flow heterogeneity was expressed as relative dispersion (RD) and computed as standard deviation/mean. In postischemic vs. preischemic hearts, RD was increased for the whole LV (0.92 +/- 0.41 vs. 0.37 +/- 0.07, P < 0.05) as well as the subendocardium (Endo) and subepicardium considered separately (1.28 +/- 0.74 vs. 0.30 +/- 0.09 and 0.69 +/- 0.22 vs. 0.38 +/- 0.08; P < 0.05 for both comparisons, respectively) during early reperfusion. During late reperfusion, the increased RD for the whole LV and Endo remained significant (0.70 +/- 0.22 vs. 0.37 +/- 0.07 and 1.06 +/- 0.55 vs. 0.30 +/- 0.09; P < 0.05 for both comparisons, respectively). In addition to the increase in postischemic flow heterogeneity, there were some regions demonstrating severely impaired reflow, indicating that regional ischemia can persist despite restoration of normal global flow. Also, the relationship between regional and global flow was altered by the increased postischemic flow heterogeneity, substantially reducing the significance of measured global LV reflow. These observations emphasize the need to quantify regional flow during reperfusion after sustained no-flow ischemia in the isolated rabbit heart.

Animals↗

Scatter correction for positron emission mammography.

In this paper we present a scatter correction method for a regularized list mode maximum likelihood reconstruction algorithm for the positron emission mammograph (PEM) that is being developed at our laboratory. The scatter events inside the object are modelled as additive Poisson random variables in the forward model of the reconstruction algorithm. The mean scatter sinogram is estimated using a Monte Carlo simulation program. With the assumption that the background activity is nearly uniform, the Monte Carlo scatter simulation only needs to run once for each PEM configuration. This saves computation time. The crystal scatters are modelled as a shift-invariant blurring in image domain because they are more localized. Thus, the useful information in the crystal scatters can be deconvolved in high-resolution reconstructions. The propagation of the noise from the estimated scatter sinogram into the reconstruction is analysed theoretically. The results provide an easy way to calculate the required number of events in the Monte Carlo scatter simulation for a given noise level in the image. The analysis is also applicable to other scatter estimation methods, provided that the covariance of the estimated scatter sinogram is available.

Algorithms↗

Four-dimensional processing of deformable cardiac PET data.

A four-dimensional deformable motion algorithm is described for use in the motion compensation of gated cardiac positron emission tomography. The algorithm makes use of temporal continuity and a non-uniform elastic material model to provide improved estimates of heart motion between time frames. Temporal continuity is utilized in two ways. First, incremental motion fields between adjacent time frames are calculated to improve estimation of long-range motion between distant time frames. Second, a consistency criterion is used to insure that the image match between distant time frames is consistent with the deformations used to match adjacent time frames. The consistency requirement augments the algorithm's ability to estimate motion between noisy time frames, and the concatenated incremental motion fields improve estimation for large deformations. The estimated motion fields are used to establish a voxel correspondence between volumes and to produce a motion-compensated composite volume.

Algorithms↗

Correction for ambiguous solutions in factor analysis using a penalized least squares objective.

Factor analysis is a powerful tool used for the analysis of dynamic studies. One of the major drawbacks of factor analysis of dynamic structures (FADS) is that the solution is not mathematically unique when only nonnegativity constraints are used to determine factors and factor coefficients. In this paper, a method to correct for ambiguous FADS solutions has been developed. A nonambiguous solution (to within certain scaling factors) is obtained by constructing and minimizing a new objective function. The most common objective function consists of a least squares term that when minimized with nonnegativity constraints, forces agreement between the applied factor model and the measured data. In our method, this objective function is modified by adding a term that penalizes multiple components in the images of the factor coefficients. Due to nonuniqueness effects, these factor coefficients consist of more than one physiological component. The technique was tested on computer simulations, an experimental canine cardiac study using 99mTc-teboroxime, and a patient planar 99mTc-MAG3 renal study. The results show that the technique works well in comparison to the truth in computer simulations and to region of interest (ROI) measurements in the experimental studies.

Algorithms↗

Removal of liver activity contamination in teboroxime dynamic cardiac SPECT imaging with the use of factor analysis.

BACKGROUND: One of the major problems associated with technetium 99m teboroxime cardiac imaging is the high concentration of activity in the liver. In some cases it is impossible to diagnose defects on the inferior wall because of the finite resolution and scatter that cause images of the inferior wall and the liver to overlap. METHODS AND RESULTS: The least-squares factor analysis of dynamic structures method, with correction for non-unique solutions, was used to remove the liver activity from the image. The method was applied to dynamically acquired Tc-99m teboroxime data. The liver activity removal method was tested through use of computer simulations and tomographically acquired canine and patient cardiac studies. In all studies the least-squares factor analysis of dynamic structures method was able to extract the liver activity from the series of dynamic images, thereby making it possible to remove it quantitatively from the entire series. The method was used successfully to remove the liver activity that partially overlapped the inferior wall in normal hearts. The method tends to increase the contrast between defects and normal myocardial tissue in abnormal hearts. CONCLUSIONS: The method presented can be used to assist in diagnosis of cardiac disease when dynamically acquired teboroxime data are used. Because the contrast between the defect and normal myocardial tissue can be changed, the processed image cannot be used by itself to make an accurate diagnosis. However, with the liver activity removed, the image provides additional information that is very useful in the imaging of patients whose liver activity overlaps the inferior heart wall.

Animals↗