PubMed Health⌕ Search

Biomedical subjects

Ronald M Summers

Publications and source records attributed to Ronald M Summers.

At least 19 recordsLinked to original sources

Revisiting oral barium sulfate contrast agents.

Oral contrast agents used during CT colonography (CTC) are valuable and may reduce false positive and false negative detections due to stool and residual fluid. Electronic cleansing algorithms are feasible, and oral contrast agents can eliminate the CTC requirement for a clean colon. Recent work shows oral contrast frequently adheres to polyps, with a preference for those with villous histology, a characteristic of advanced polyps. This finding encourages the development of contrast agents that highlight polyps at greatest risk for progression to malignancy. Our review summarizes numerous aspects of oral barium sulfate contrast agents as well as tests to assess adherence and coating ability of the agents, offering arenas to explore and tools for evaluation.

Administration, Oral↗

CT colonography with computer-aided polyp detection: volume and attenuation thresholds to reduce false-positive findings owing to the ileocecal valve.

PURPOSE: To retrospectively identify volume and average attenuation thresholds for differentiating between ileocecal valve (ICV) and polyp at computed tomographic (CT) colonography with computer-aided detection (CAD). MATERIALS AND METHODS: Informed consent (with consent for future retrospective research) and institutional review board (IRB) approval were obtained for the original prospective study. This retrospective study had IRB approval, as well, and was HIPAA-compliant. A total of 496 patients were selected from a larger screening population. CT colonographic images from 394 patients (227 men, 167 women; mean age, 58.0 years; range, 40-79 years) were used as a training set, and images from 102 patients (76 men, 26 women; mean age, 59.8 years; range, 46-79 years) were used as a test set. A series of 2742 volume and attenuation thresholds, for which segmented findings both larger in volume and lower in average attenuation were labeled as ICVs and remaining findings were labeled polyps, were applied to the training set to determine settings with 100% sensitivity for polyp detection and the highest specificity for ICV detection. The optimal settings were then applied to the test set. Significance was assessed with the Fisher exact test, and 95% confidence intervals (CIs) were computed for sensitivity and specificity. RESULTS: A total of 386 ICVs and 67 adenomatous polyps from the training set and 102 ICVs and 138 adenomatous polyps from the test set could be segmented with a three-dimensional segmentation algorithm. When supine and prone images were counted individually, 746 nonunique ICVs from the training set and 191 from the test set were segmentable. In the training set, a volume of 600 mm(3) and an attenuation of 36 HU provided 100% sensitivity (67 polyps; 95% CI: 93%, 100%) and the optimal 83% specificity (618 of 746 ICVs; 95% CI: 80%, 85%). When applied to the test set, this combination provided 97% sensitivity (134 of 138 polyps; 95% CI: 92%, 99%) and 84% specificity (160 of 191 ICVs; 95% CI: 78%, 89%). Differences in sensitivity and specificity in the detection of polyps between the sets were not significant. CONCLUSION: Volume and average CT attenuation thresholds can help differentiate most ICVs from true polyps.

Adult↗

Assessment of polyp and mass histopathology by intravenous contrast-enhanced CT colonography.

RATIONALE AND OBJECTIVES: We sought to demonstrate that intravenous contrast-enhanced CT colonography (CTC) can distinguish colonic adenomas from carcinomas. METHODS: Supine intravenous contrast-enhanced CTC with colonoscopic and/or surgical correlation was performed on 25 patients with colonic adenomas or carcinomas. Standard deviation of mean polyp CT attenuation was computed and assessed using ANOVA and receiver-operating characteristic analyses. RESULTS: Colonoscopy confirmed 32 polyps or masses 1 to 8 cm in size. The standard deviations of CT attenuation were carcinomas (n = 13; 36 +/- 6 HU; range 28-48 HU) and adenomas (n = 19; 49 +/- 14 HU; range 31-100 HU) (P = 0.005). At a standard deviation threshold of 42 HU, the sensitivity and specificity for classifying a polyp or mass as a carcinoma were 92% and 79%, respectively. The area under the receiver-operating characteristic curve was 0.89 +/- 0.06 (95% confidence interval 0.73-0.96). CONCLUSIONS: Measurement of the standard deviation of CT attenuation on intravenous contrast-enhanced CTC permits histopathologic classification of polyps 1 cm or larger as carcinomas versus adenomas. The presence of ulceration or absence of muscular invasion in carcinomas creates overlap with adenomas, reducing the specificity of carcinoma classification.

Adenoma↗

Hybrid segmentation of colon filled with air and opacified fluid for CT colonography.

Reliable segmentation of the colon is a requirement for three-dimensional visualization programs and automatic detection of polyps on computed tomography (CT) colonography. There is an evolving clinical consensus that giving patients positive oral contrast to tag out remnants of stool and residual fluids is mandatory. The presence of positive oral contrast in the colon adds an additional challenge for colonic segmentation but ultimately is beneficial to the patient because the enhanced fluid helps reveal polyps in otherwise hidden areas. Therefore, we developed a new segmentation procedure which can handle both air- and fluid-filled parts of the colon. The procedure organizes individual air- and fluid-filled regions into a graph that enables identification and removal of undesired leakage outside the colon. In addition, the procedure provides a risk assessment of possible leakage to assist the user prior to the tedious task of visual verification. The proposed hybrid algorithm uses modified region growing, fuzzy connectedness and level set segmentation. We tested our algorithm on 160 CT colonography scans containing 183 known polyps. All 183 polyps were in segmented regions. In addition, visual inspection of 24 CT colonography scans demonstrated good performance of our procedure: the reconstructed colonic wall appeared smooth even at the interface between air and fluid and there were no leaked regions.

Air↗

Polyps: linear and volumetric measurement at CT colonography.

PURPOSE: To retrospectively determine which of several computed tomographic (CT) colonography-based polyp measurements is most compatible with the linear measurement at optical colonoscopy and which is best for assessing change in polyp size. MATERIALS AND METHODS: This HIPAA-compliant study had institutional review board approval; informed consent was obtained. Prone and supine CT colonography with same-day optical colonoscopy was performed in 216 patients (147 men and 69 women; age range, 46-79 years; mean age, 59.2 years) with 338 polyps detected at CT colonography. Polyp size was measured with three linear measurements and two volume measurements. One linear measurement and one volume measurement were performed by using automated segmentation; remaining measurements were performed manually. Compatibility with linear size at optical colonoscopy and measurement reproducibility were assessed three ways: variation from size measurement at optical colonoscopy, change between prone and supine scans, and variability between observers. Confidence analysis assessed the ability of each measurement to identify polyps with an optical colonoscopy measurement of 1 cm or greater. RESULTS: Two hundred fifty-one segmentable polyps were present on both supine and prone scans. Linear polyp diameter manually measured on a three-dimensional endoluminally viewed surface (L(M3D)) indicated with 95% confidence that a polyp measured as 0.8 cm or smaller was less than 1.0 cm at optical colonoscopy. Prone and supine polyp size difference was smallest for L(M3D) and the linear diameter computed from manual and automated volume measurements, with interquartile ranges smaller than or equal to 0.3, 0.2, and 0.5 cm, respectively. Interobserver and intraobserver variability was smallest for linear polyp diameter measurements on a two-dimensional display, with a mean percentage difference of 2.8% (95% Bland-Altman limits of agreement: -17.8%, 23.4%) and 5.0% (95% Bland-Altman limits of agreement: -28.3%, 38.3%), respectively. CONCLUSION: L(M3D) best approximated polyp size measurements at optical colonoscopy. Linear diameter calculated from automated volume measurements showed the smallest variation between supine and prone scans while avoiding observer variability and may be best for assessing polyp size changes with serial examinations.

Adult↗

Support vector machines committee classification method for computer-aided polyp detection in CT colonography.

RATIONALE AND OBJECTIVES: A new classification scheme for the computer-aided detection of colonic polyps in computed tomographic colonography is proposed. MATERIALS AND METHODS: The scheme involves an ensemble of support vector machines (SVMs) for classification, a smoothed leave-one-out (SLOO) cross-validation method for obtaining error estimates, and use of a bootstrap aggregation method for training and model selection. Our use of an ensemble of SVM classifiers with bagging (bootstrap aggregation), built on different feature subsets, is intended to improve classification performance compared with single SVMs and reduce the number of false-positive detections. The bootstrap-based model-selection technique is used for tuning SVM parameters. In our first experiment, two independent data sets were used: the first, for feature and model selection, and the second, for testing to evaluate the generalizability of our model. In the second experiment, the test set that contained higher resolution data was used for training and testing (using the SLOO method) to compare SVM committee and single SVM performance. RESULTS: The overall sensitivity on independent test set was 75%, with 1.5 false-positive detections/study, compared with 76%-78% sensitivity and 4.5 false-positive detections/study estimated using the SLOO method on the training set. The sensitivity of the SVM ensemble retrained on the former test set estimated using the SLOO method was 81%, which is 7%-10% greater than the sensitivity of a single SVM. The number of false-positive detections per study was 2.6, a 1.5 times reduction compared with a single SVM. CONCLUSION: Training an SVM ensemble on one data set and testing it on the independent data has shown that the SVM committee classification method has good generalizability and achieves high sensitivity and a low false-positive rate. The model selection and improved error estimation method are effective for computer-aided polyp detection.

Algorithms↗

Automated seed placement for colon segmentation in computed tomography colonography.

RATIONALE AND OBJECTIVE: To present an algorithm to automatically locate seeds for colon segmentation in computed tomography colonography (CTC). MATERIALS AND METHODS: The algorithm automatically locates two points (seeds) inside the colon lumen. Because of their high distention and fixed anatomic position, we focus on the cecum and rectum for automatic seed placement. We use two-dimensional morphological operators that find pockets of colonic air of sufficient size. For the rectum, we search within an inferiorly and centrally located CT slice. For the cecum, we search in a group of CT slices in the middle of the scanned volume on the patient's right side. We applied our automated algorithm to segment the colon in 292 consecutive cases of CTC (146 prone, 146 supine). RESULTS: After automated seed placement, 83.2% (243 of 292) of the colons were segmented completely and 9.6% (28 of 292) were segmented partially. The unsegmented colon parts were present in datasets where the colon was collapsed in more than one place or because seeds could not be placed in regions filled with fluid. In the remaining 7.2% (21 of 292) of cases, the automatic segmentation leaked outside the colon because of a limitation of the contrast-enhanced fluid detection algorithm. CONCLUSION: Fully automatic seed placement for colonic segmentation is feasible in the majority of cases without seeding of undesired extracolonic air.

Adult↗

Computed tomographic virtual colonoscopy computer-aided polyp detection in a screening population.

BACKGROUND & AIMS: The sensitivity of computed tomographic (CT) virtual colonoscopy (CT colonography) for detecting polyps varies widely in recently reported large clinical trials. Our objective was to determine whether a computer program is as sensitive as optical colonoscopy for the detection of adenomatous colonic polyps on CT virtual colonoscopy. METHODS: The data set was a cohort of 1186 screening patients at 3 medical centers. All patients underwent same-day virtual and optical colonoscopy. Our enhanced gold standard combined segmental unblinded optical colonoscopy and retrospective identification of precise polyp locations. The data were randomized into separate training (n = 394) and test (n = 792) sets for analysis by a computer-aided polyp detection (CAD) program. RESULTS: For the test set, per-polyp and per-patient sensitivities for CAD were both 89.3% (25/28; 95% confidence interval, 71.8%-97.7%) for detecting retrospectively identifiable adenomatous polyps at least 1 cm in size. The false-positive rate was 2.1 (95% confidence interval, 2.0-2.2) false polyps per patient. Both carcinomas were detected by CAD at a false-positive rate of 0.7 per patient; only 1 of 2 was detected by optical colonoscopy before segmental unblinding. At both 8-mm and 10-mm adenoma size thresholds, the per-patient sensitivities of CAD were not significantly different from those of optical colonoscopy before segmental unblinding. CONCLUSIONS: The per-patient sensitivity of CT virtual colonoscopy CAD in an asymptomatic screening population is comparable to that of optical colonoscopy for adenomas > or = 8 mm and is generalizable to new CT virtual colonoscopy data.

Adenomatous Polyps↗

Virtual colonoscopy.

Explore the source record for details and available documents.

Colonography, Computed Tomographic↗

Validation and clinical significance of the Childhood Myositis Assessment Scale for assessment of muscle function in the juvenile idiopathic inflammatory myopathies.

OBJECTIVE: To examine the measurement characteristics of the Childhood Myositis Assessment Scale (CMAS) in children with juvenile idiopathic inflammatory myopathy (juvenile IIM), and to obtain preliminary data on the clinical significance of CMAS scores. METHODS: One hundred eight children with juvenile IIM were evaluated on 2 occasions, 7-9 months apart, using various measures of physical function, strength, and disease activity. Interrater reliability, construct validity, and responsiveness of the CMAS were examined. The minimum clinically important difference (MID) and CMAS scores corresponding to various degrees of physical disability were estimated. RESULTS: The intraclass correlation coefficient for 26 patients assessed by 2 examiners was 0.89, indicating very good interrater reliability. The CMAS score correlated highly with the Childhood Health Assessment Questionnaire (C-HAQ) score and with findings on manual muscle testing (MMT) (r(s) = -0.73 and 0.73, respectively) and moderately with physician-assessed global disease activity and skin activity, parent-assessed global disease severity, and muscle magnetic resonance imaging (r(s) = -0.44 to -0.61), thereby demonstrating good construct validity. The standardized response mean was 0.81 (95% confidence interval 0.53, 1.09) in patients with at least 0.8 cm improvement on a 10-cm visual analog scale for physician-assessed global disease activity, indicating strong responsiveness. In bivariate regression models predicting physician-assessed global disease activity, MMT remained significant in models containing the CMAS (P = 0.03) while the C-HAQ did not (P = 0.4). Estimates of the MID ranged from 1.5 to 3.0 points on a 0-52-point scale. CMAS scores corresponding to no, mild, mild-to-moderate, and moderate physical disability, respectively, were 48, 45, 39, and 30. CONCLUSION: The CMAS exhibits good reliability, construct validity, and responsiveness, and is therefore a valid instrument for the assessment of physical function, muscle strength, and endurance in children with juvenile IIM. Preliminary data on MID and corresponding levels of disability should aid in the clinical interpretation of CMAS scores when assessing patients with juvenile IIM.

Adolescent↗

Computer-assisted detection of subcutaneous melanomas: feasibility assessment.

RATIONALE AND OBJECTIVES: Subcutaneous melanomas may be missed on computed tomography because of their peripheral location or perceived unimportance, yet they can have clinical significance. The use of a novel computer-assisted detection scheme to locate subcutaneous melanoma lesions in body CT images was investigated. MATERIALS AND METHODS: The detection software segments subcutaneous fat from the rest of the body and searches for soft tissue density lesions that match a size and shape constraint. Sensitivity and specificity of the proposed method was analyzed by comparing automated lesion detection results in eight patients with 118 subcutaneous melanomas with ground truth data derived from manual tracings of a trained observer. RESULTS: The sensitivity of subcutaneous melanoma detection was 86%. The false-positive rate was 3.1 per slice. Analysis of the false-positives showed that the most common cause was incorrect classification of muscle as a nodule. CONCLUSION: This study showed the feasibility of a fully automatic subcutaneous melanoma lesion detection system having good sensitivity. The false-positive rate was high, but avenues for further reduction were identified.

Adult↗

Virtual bronchoscopy for evaluation of airway disease.

The data presented above indicate that VB is a novel and extremely useful modality for airway evaluation in patients who have benign and malignant disease. VB is noninvasive, with no additional radiation exposure relative to standard CT scans of the chest. Commercial software allows for the interactivity of 2D and 3D images. The ability to examine 2D and 3D anatomic detail from multiple directions enables precise assessment of intraluminal and extraluminal pathology. The authors' experience indicates that VB is a superb modality for assessing the length of airway stenoses and ascertaining airway patency distal to these lesions (Fig. 6). As such, VB has proven to be extremely useful for determining the feasibility of endobronchial procedures such as dilations, stent placements, and laser ablation of endobronchial tumors. Ferretti et al [27] observed that VB is an excellent noninvasive means for long-term monitoring of tracheobronchial stents. Furthermore, the authors have found VB useful for guiding the bronchoscopic evaluation of patients who have intermittent hemoptysis secondary to lesions in peripheral airways. The 3D anatomic detail provided by VB has proven useful for assessing the feasibility of lung-sparing procedures in patients who have limited pulmonary reserve and for sequentially evaluating treatment response in patients who have inoperable disease. Currently, the main limitation of VB pertains to its inability to evaluate the mucosal surface of the respiratory tract reliably. Although form can be detected, mucosal color, irregularity, or friability cannot be assessed. As such, VB cannot be used for routine surveillance of patients at high risk of developing airway malignancies. The development of novel aerosolized contrast agents or spectroscopic techniques that can discriminate benign versus malignant mucosal tissues might enhance the sensitivity and specificity of VB for the detection of preinvasive cancers within the respiratory tract.

Adult↗

Colonic polyp segmentation in CT colonography-based on fuzzy clustering and deformable models.

An automatic method to segment colonic polyps in computed tomography (CT) colonography is presented in this paper. The method is based on a combination of knowledge-guided intensity adjustment, fuzzy c-mean clustering, and deformable models. The computer segmentations were compared with manual segmentations to validate the accuracy of our method. An average 76.3% volume overlap percentage among 105 polyp detections was reported in the validation, which was very good considering the small polyp size. Several experiments were performed to investigate the intraoperator and interoperator repeatability of manual colonic polyp segmentation. The investigation demonstrated that the computer-human repeatability was as good as the interoperator repeatability. The polyp segmentation was also applied in computer-aided detection (CAD) to reduce the number of false positive (FP) detections and provide volumetric features for polyp classification. Our segmentation method was able to eliminate 30% of FP detections. The volumetric features computed from the segmentation can further reduce FP detections by 50% at 80% sensitivity.

Algorithms↗

Tracheal and central bronchial aerodynamics using virtual bronchoscopy and computational fluid dynamics.

Virtual bronchoscopy reconstructions of the airway noninvasively provide useful morphologic information of structural abnormalities such as stenoses and masses. In this paper, we show how virtual bronchoscopy can be used to perform aerodynamic calculations in anatomically realistic models. Pressure and flow patterns in a human airway were computed noninvasively. These showed decreased pressure and increased shear stress in the region of a stenosis.

Air Movements↗

Reduction of false positives on the rectal tube in computer-aided detection for CT colonography.

PURPOSE: To eliminate false-positive (FP) polyp detections on the rectal tube (RT) in CT colonography (CTC) computer-aided detection (CAD). METHODS: We use a three-stage approach to detect the RT: detect the RT shaft, track the tube to the tip and label all the voxels that belong to the RT. We applied our RT detection algorithm on a CTC dataset consisting of 80 datasets (40 patients scanned in both prone and supine positions). Two different types of RTs were present, characterized by differences in shaft/bulb diameters, wall intensities, and shape of tip. RESULTS: The algorithm detected 90% of RT shafts and completely tracked 72% of them. We labeled all the voxels belonging to the completely tracked RTs (72%) and in 11 out of 80 (14%) cases the RT voxels were partially labeled. We obtained a 9.2% reduction of the FPs in the initial polyp candidates' population, and a 7.9% reduction of the FPs generated by our CAD system. None of the true-positive detections were mislabeled. CONCLUSIONS: The algorithm detects the RTs with good accuracy, is robust with respect to the two different types of RT used in our study, and is effective at reducing the number of RT FPs reported by our CAD system.

Algorithms↗