Dual focal-spot imaging for phase extraction in phase-contrast radiography.

The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as "unsharp masking" but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects.

Algorithms↗

Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography.

The purpose of this study was to evaluate the effects of system parameters (focal spot size, tube voltage, geometry, detector resolution, and image noise) and object characteristics (edge gradient/ shape, composition, thickness, and overlying attenuating material) upon the edge enhancement effect in phase-contrast radiography. Each variable of interest was adjusted and images of a 3 mm lucite phantom were obtained with the other variables remaining constant. A microfocus x-ray source coupled to a CCD camera with an intensifying screen was used to acquire the digital images. Two parameters of image analysis were used to quantify the effects. The edge enhancement index (EEI) was used to measure the absolute degree of edge enhancement, while the edge enhancement to noise ratio (EE/N) was used to measure the conspicuity of the edge enhancement relative to image noise. Little effect on EEI was seen from tube voltage, object thickness, overlying attenuating material, while focal spot size and system geometry demonstrated measurable effects upon the degree of edge enhancement. It was also shown that while the edge enhancement effect over straight edges is highly dependent upon how the edge aligns with the x-ray beam, rounded edges, which better model biological objects, do not suffer from this dependence and the EEI reaches its maximal level at any alignment. Decreasing detector resolution diminished the EEI slightly, but even with pixel sizes of 0.360 x 0.360 mm edge enhancement effects were readily visible. The effect of image noise on EE/N was evaluated using different exposure times showing an expected improvement with longer exposure time with EE/N approaching a plateau at 5 min. Many of the parameters that will go into the design of a future PC-R imaging system have been quantified in terms of their effect on the degree of edge enhancement in the acquired image. These results, taken together, indicate that either a specimen or even clinical breast imaging system could be created with currently available technology. The major limitation to a clinical system would be the low x-ray flux from the microfocal x-ray source.

Pattern Recognition, Automated↗

Longitudinal brain metabolic characterization of chronic alcoholics with proton magnetic resonance spectroscopy.

BACKGROUND: Proton magnetic resonance spectroscopy may elucidate the molecular underpinnings of alcoholism-associated brain shrinkage and the progression of alcohol dependence. METHODS: Using proton magnetic resonance spectroscopy, we determined absolute concentrations of -acetylaspartate (NAA), creatine/phosphocreatine (Cr), and choline (Cho)-containing compounds and -inositol (mI) in the anterior superior cerebellar vermis and frontal lobe white matter in 31 alcoholics and 12 normal controls. All patients were examined within 3 to 5 days of their last drink. Patients who did not relapse were again studied after 3 weeks and 3 months of abstinence by using an on-line repositioning technique that allows reliable localization of volumes of interest (VOIs). RESULTS: At 3 to 5 days after the last drink, frontal white matter metabolite concentrations were not significantly different from those of normal controls, whereas brain tissue in the VOI was reduced. Cerebellar [NAA] and [Cho] and brain and cerebellar volumes were decreased, but [Cr], [mI], and VOI brain tissue volume were not significantly different. Eight patients relapsed before 3 weeks (ER), 12 relapsed between 3 weeks and 3 months (LR), and 11 did not relapse (NR) during 3 months. Cerebellar [NAA] was reduced only in ER patients, despite the fact that ER patients drank for significantly fewer years and earlier in life than LR or NR patients. After 3 months, in the 11 continuously abstinent patients, cerebellar [NAA] and brain and cerebellar volumes increased; cerebellar [Cho], [Cr], and [mI] and VOI brain tissue did not change significantly. CONCLUSIONS: Decreased [NAA] and [Cho] in cerebellar vermis indicate a unique sensitivity to alcohol-induced brain injury. Cerebellar [NAA] increased with abstinence, but reduced [Cho] persisted beyond 3 months. Further studies are needed to determine whether low cerebellar [NAA] is a risk factor for, or consequence of, malignant, early-onset alcoholism.

Adult↗

Quantification of the effect of kvp on edge-enhancement index in phase-contrast radiography.

This study was performed to measure the dependence of edge-enhancement in polychromatic phase-contrast radiography on x-ray tube operating voltage. Measurements of edge enhancement were made at tube voltages from 40 to 86 kVp using a tungsten anode x-ray tube with a nominal focal spot size of 100 micrometers. A relatively weak attenuating, sharp edge consisting of a thin lucite sheet (3 mm) in air was imaged utilizing phase-contrast radiography (PC-R). PC-R images were acquired at different radiographic techniques in which x-ray tube voltage was varied from 40 to 86 kVp. The image receptor was a single emulsion x-ray mammography cassette. Optical density profiles across the edge of the object were obtained using a film digitizer and edge-enhancement indices were calculated. Increasing kVp resulted in a gradual decrease of the edge-enhancement index. Even at the highest kVp (86), however, important edge-enhancement effects were evident. While there is some degradation in the edge-enhancement effect of phase-contrast radiography at higher kVps, the decrease from 40 to 86 kVp is relatively small (11%). Our results suggest that further investigation into the role of phase-contrast imaging at higher kVp values for the purpose of patient dose reduction while still realizing the advantage of phase-contrast effects for improved soft-tissue detectability is warranted.

Image Processing, Computer-Assisted↗

Practical aspects of functional MRI (NMR Task Group #8).

Functional MR imaging (fMRI) based upon the Blood Oxygen Level Dependent (BOLD) effect is currently an important new tool for understanding basic brain function and specifically allowing the correlation of physiological activity with anatomical location without the use of ionizing radiation. The clinical role of fMRI is still being defined and is the subject of much research activity. In this report we present the underlying physical, technical and mathematical principals of BOLD fMRI along with descriptions of typical applications. Our purpose in this report is to provide, in addition to basic principles, an insight into the aspects of BOLD imaging, which may be used by the medical physicist to assist in the implement of fMRI procedures in either a hospital or research environment.

Brain↗

Targeted molecular imaging agents for cellular-scale bimodal imaging.

Molecular imaging is a powerful tool that has the ability to elucidate biochemical mechanisms and signal the early onset of disease. Overexpression of the peripheral benzodiazepine receptor (PBR) has been observed in a variety disease states, including glioblastoma, breast cancer, and Alzheimer's disease. Thus, the PBR could be an attractive target for molecular imaging. In this paper, the authors report cellular uptake and multimodal (MRI and fluorescence) imaging of PBR-overexpressing C6 glioblastoma (brain cancer) cells using a cocktail administration approach and a new PBR targeted lanthanide chelate molecular imaging agent.

Animals↗

Chitosan cross-linking with a water-soluble, blocked diisocyanate. 1. Solid state.

The present investigation focuses on the synthesis and application of a cross-linking agent that is compatible with the solubility characteristics of chitosan. A water-soluble, blocked-diisocyanate was prepared as a bisulfite adduct to 1,6-hexamethylene diisocyanate, which proved to be stable for several weeks in aqueous, acidic chitosan solutions at room temperature. Thermal cross-linking of chitosan as cast, dried films was investigated by varying the NCO/NH(2) ratio from 0.0 to 1.2. Spectroscopic (IR), thermal (TGA), swelling, and structural (WAXD) studies indicated that chitosan was cross-linked in a concentration-dependent manner under mild thermal conditions: 60 degrees C for 24 h. Cross-linking inefficiency was concluded to be due to lack of mobility of the reacting species in the solid state. In a preliminary study, the enzymatic degradation with Chitinase (E. C. 3.2.1.14) from Streptomyces griseus was found to be the greatest for non-crosslinked chitosan, followed by chitin, and then by cross-linked samples.

Biodegradation, Environmental↗

Chitosan cross-linking with a water-soluble, blocked diisocyanate. 2. Solvates and hydrogels.

A water-soluble, blocked diisocyante was used to cross-link chitosan under various degrees of solvation, including hydration to form hydrogels. Thermal cross-linking of films cast from various amounts of organic cosolvents was found to increase with increased level of cosolvent up to a solvation level of 17% (w/w) and to be more efficient than for films prepared without cosolvent. Rheological studies revealed that gel modulus increased and gel time decreased with increasing cross-linker content and that gelation kinetics were consistent with a process having an activation energy of 103 kJ/mol. Swelling of hydrogels indicated that, even at high levels of hydration, the increased molecular mobility of reactants allowed for efficient network formation in a concentration-dependent manner. The extent of solvation via equilibrium swelling correlated well with degradative properties of chitosan networks in the presence of Chitinase (E. C. 3.2.1.14) from Streptomyces griseus with stability increasing with decreasing swelling (i.e., increased cross-linking).

Biodegradation, Environmental↗