PubMed Health⌕ Search

Biomedical subjects

Rong Yan

Publications and source records attributed to Rong Yan.

11 recordsLinked to original sources

Combined effect of adsorption and biodegradation of biological activated carbon on H2S biotrickling filtration.

In order to evaluate the combined effect of adsorption and biodegradation of H(2)S on activated carbon surface in biotrickling filtration, four laboratory-scale biofiltration columns were operated simultaneously for 120h to investigate the mechanisms involved in treating synthetic H(2)S streams using biological activated carbon (BAC). The first three columns (A, B, C) contained a mixture of activated carbon and glass beads, with the carbons (BAC or virgin activated carbon (VAC)) and conditions (with or without liquid medium recirculation) differentiated. The last column (D) used 100% glass beads with liquid medium recirculation. Air streams containing 45ppmv H(2)S were passed through the columns at 4s of gas retention time (GRT) and liquid flow rate was set at 0.71mlmin(-1). Column D got its breakthrough in 3min of operation, indicating a negligible contribution of glass beads to the adsorption of H(2)S. The removal efficiency (RE) of Columns B and C using VAC dropped quickly to 30% within the first 8h, and afterwards continued to drop further but slowly. Column A using BAC stayed at 25% of RE throughout the operation time. A thorough investigation of the H(2)S oxidation products, i.e., various S species in both aqueous (recirculation media) and solid phases (BAC and VAC), was conducted using ICP-OES, IC, XRF, and CHNS elemental analyzer. BAC demonstrated a better performance than columns with adsorption only. Water film was found to enhance H(2)S removal. The percentage of sulphate in the total sulphur of the BAC system improved to twice of that of VAC system, indicating sulphate is the main product of H(2)S biofiltration. The observed pH drop in BAC system double confirmed that the presence of biodegradation in the biofilm over carbon surface did profound effect on the oxidation of H(2)S, compare to the systems with adsorption only.

Adsorption↗

Biological treatment of H(2)S using pellet activated carbon as a carrier of microorganisms in a biofilter.

Biological treatment is an emerging technology for treating off-gases from wastewater treatment plants. The most commonly reported odourous compound in off-gases is hydrogen sulfide (H(2)S), which has a very low odor threshold. This study aims to evaluate the feasibility of using a biological activated carbon as a novel packing material, to achieve a performance-enhanced biofiltration processes in treating H(2)S through an optimum balance and combination of the adsorption capacity with the biodegradation of H(2)S by the bacteria immobilized on the material. The biofilm was mostly developed through culturing the bacteria in the presence of carbon pellets in mineral media. Scanning electron microscopy (SEM) was used to identify the biofilm development on carbon surface. Two identical laboratory scale biofilters, one was operated with biological activated carbon (BAC) and another with virgin carbon without bacteria immobilization. Various concentrations of H(2)S (up to 125 ppmv) were used to determine the optimum column performance. A rapid startup (a few days) was observed for H(2)S removal in the biofilter. At a volumetric loading of 1600 m(3)m(-3)h(-1) (at 87 ppmv H(2)S inlet concentration), elimination capacity of the BAC (181 gH(2)Sm(-3)h(-1)) at removal efficiency (RE) of 94% was achieved. If the inlet concentration was kept at below 30 ppmv, high H(2)S removal (over 99%) was achieved at a gas retention time (GRT) as low as 2s, a value, which is shorter than most previously reported for biofilter operations. The bacteria population in the acidic biofilter demonstrated capacity for removal of H(2)S in a broad pH range (pH 1-7). There are experimental evidences showing that the spent BAC could be re-used as packing material in a biofilter based on BAC. Overall, the results indicated that an unprecedented performance could be achieved by using BAC as the supporting media for H(2)S biofiltration.

Bioreactors↗

A discriminative learning framework with pairwise constraints for video object classification.

To deal with the problem of insufficient labeled data in video object classification, one solution is to utilize additional pairwise constraints that indicate the relationship between two examples, i.e., whether these examples belong to the same class or not. In this paper, we propose a discriminative learning approach which can incorporate pairwise constraints into a conventional margin-based learning framework. Different from previous work that usually attempts to learn better distance metrics or estimate the underlying data distribution, the proposed approach can directly model the decision boundary and, thus, require fewer model assumptions. Moreover, the proposed approach can handle both labeled data and pairwise constraints in a unified framework. In this work, we investigate two families of pairwise loss functions, namely, convex and nonconvex pairwise loss functions, and then derive three pairwise learning algorithms by plugging in the hinge loss and the logistic loss functions. The proposed learning algorithms were evaluated using a people identification task on two surveillance video data sets. The experiments demonstrated that the proposed pairwise learning algorithms considerably outperform the baseline classifiers using only labeled data and two other pairwise learning algorithms with the same amount of pairwise constraints.

Algorithms↗

Investigation on the mechanism of H(2)S removal by biological activated carbon in a horizontal biotrickling filter.

The use of supporting media for the immobilization of microorganisms is widely known to provide a surface for microbial growth and a shelter that protects the microorganisms from inhibitory compounds. In our previous studies, activated carbon (AC) alone used as a support medium for H(2)S biological removal was proved prompt and efficient in a bench-scale biofilter and biotrickling filter. In this study, the mechanisms of H(2)S elimination using microbial immobilized activated carbon, i.e., biological activated carbon (BAC), are investigated. A series of BAC as supporting medium were taken from the inlet to outlet of a bench-scale horizontal biotrickling filter to examine the different effects of physical/chemical adsorption and microbial degradation on the overall removal of H(2)S. The surface properties of BAC together with virgin and exhausted carbon (after H(2)S breakthrough test, non-microbial immobilization) were characterized using the sorption of nitrogen (Braunner-Emmett-Teller test), scanning electron microscopy (SEM), surface pH, thermal, carbon-hydrogen-nitrogen-sulfur (CHNS) elemental and Fourier transform infrared (FTIR) analyses. Tests of porosity and surface area provide detailed information about the pore structure of BAC along the bed facilitating the understanding of potential pore blockages due to biofilm coating. A correlation between the available surface area and pore volume with the extent of microbial immobilization and H(2)S uptake is evidenced. SEM photographs show the direct carbon structure and biofilm coated on carbon surface. FTIR spectra, differential thermogravimetric curves and CHNS results indicate less diversity of H(2)S oxidation products on BAC than those previously observed on exhausted carbon from H(2)S adsorption only. The predominant oxidation product on BAC is sulfuric acid, and biofilm is believed to enhance the oxidation of H(2)S on carbon surface. The combination of biodegradation and physical adsorption of using BAC in removal of H(2)S could lead to a long-term (i.e., years) good performance of biotrickling filters and biofilters based on BAC compared to carbon adsorption only.

Bacteria↗

Inhibition of thermal hyperalgesia and tactile allodynia by intrathecal administration of gamma-aminobutyric acid transporter-1 inhibitor NO-711 in rats with chronic constriction injury.

The present study was undertaken to explore the role of gamma-aminobutyric acid transporters in the neuropathic pain. On the chronic constriction injury (CCI) rats 4 doses (5, 10, 20, 40 microg in group N5, N10, N20, N40, respectively) of specific gamma-aminobutyric acid transporter-1 inhibitor NO-711 or normal saline (in group NS) were intrathecally administered before sciatic nerve ligation (pre-treatment) or at the third day after ligation (post-treatment). The paw withdrawl latency (PWL) from a noxious thermal stimulus and paw withdrawl mechanical threshold (PWMT) of von Frey filament was used as measure of thermal hyperalgesia and tactile allodynia respectively. The results demonstrated that post-treatment of NO-711 significantly suppressed thermal hyperalgesia and allodynia in CCI rats (P<0.05, P<0.01), the inhibitory effect lasted for 2 h (N40 group) and 4 h (N20 group) respectively. NO-711 inhibited thermal hyperalgesia induced by CCI in a dose-dependent manner. Intrathecal pretreatment with different doses of NO-711 delayed the occurrence of thermal hyperalgesia, but could not delay the emergence of allodynia induced by CCI. This study indicates that gamma-aminobutyric acid transporter inhibitor has anti-thermal hyperalgesia and anti-tactile allodynia effects in neuropathic rats.

Animals↗

Treatment of H2S using a horizontal biotrickling filter based on biological activated carbon: reactor setup and performance evaluation.

Biological treatment is an emerging and prevalent technology for treating off-gases from wastewater treatment plants. The most commonly reported odorous compound in off-gases is hydrogen sulfide (H(2)S), which has a very low odor threshold. A self-designed, bench-scale, cross-flow horizontal biotrickling filter (HBF) operated with bacteria immobilized activated carbon (termed biological activated carbon-BAC), was applied for the treatment of H(2)S. A mixed culture of sulfide-oxidizing bacteria dominated by Acidithiobacillus thiooxidans acclimated from activated sludge was used as bacterial seed and the biofilm was developed by culturing the bacteria in the presence of carbon pellets in mineral medium. HBF performance was evaluated systematically over approximately 120 days, depending on a series of changing factors including inlet H(2)S concentration, gas retention time (GRT), pH of recirculation solution, upset and recovery, sulfate accumulation, pressure drop, gas-liquid ratio, and shock loading. The biotrickling filter system can operate at high efficiency from the first day of operation. At a volumetric loading of 900 m(3) m(-3) h(-1) (at 92 ppmv H(2)S inlet concentration), the BAC exhibited maximum elimination capacity (113 g H(2)S/m(-3) h(-1)) and a removal efficiency of 96% was observed. If the inlet concentration was kept at around 20 ppmv, high H(2)S removal (over 98%) was achieved at a GRT of 4 s, a value comparable with those currently reported for biotrickling filters. The bacterial population in the acidic biofilter demonstrated capacity for removal of H(2)S over a broad pH range (pH 1-7). A preliminary investigation into the different effects of bacterial biodegradation and carbon adsorption on system performance was also conducted. This study shows the HBF to be a feasible and economic alternative to physical and chemical treatments for the removal of H(2)S.

Acidithiobacillus thiooxidans↗

Influence of surface properties on the mechanism of H2S removal by alkaline activated carbons.

Alkaline activated carbons are widely used as adsorbents of hydrogen sulfide (H2S), one of the major odorous compounds arising from sewage treatment facilities. Although a number of studies have explored the effects of various parameters, mechanisms of H2S adsorption by alkaline carbons are not yet fully understood. The major difficulty seems to lie in the fact that little is known with certainty about the predominant reactions occurring on the carbon surface. In this study, the surface properties of alkaline activated carbons were systematically investigated to further exploit and better understand the mechanisms of H2S adsorption by alkaline activated carbons. Two commercially available alkaline activated carbons and their representative exhausted samples (8 samples collected at different height of the column after H2S breakthrough tests) were studied. The 8 portions of the exhausted carbon were used to represent the H2S/carbon reaction process. The surface properties of both the original and the exhausted carbons were characterized using the sorption of nitrogen (BET test), surface pH, Boehm titration, thermal and FTIR analysis. Porosity and surface area provide detailed information about the pore structure of the exhausted carbons with respect to the reaction extent facilitating the understanding of potential pore blockages. Results of Boehm titration and FTIR both demonstrate the significant effects of surface functional groups, and identification of oxidation products confirmed the different mechanisms involved with the two carbons. From the DTG curves of thermal analysis, two well-defined peaks representing two products of surface reactions (i.e., sulfur and sulfuric acid) were observed from the 8 exhausted portions with gradually changing patterns coinciding with the extent of the reaction. Surface pH values of the exhausted carbons show a clear trend of pH drop along the reaction extent, while pH around 2 was observed for the bottom of the bed indicating sulfuric acid as the predominant products. Although both carbons are coal-based and of KOH impregnated type, performances of different carbons differ significantly. A correlation is well established to link the reaction extent with various surface properties. In summary, not only the homogeneous alkali impregnation and physical porosity but also the carbon surface chemistry are significant factors influencing the performances of alkaline activated carbons as H2S adsorbents.

Adsorption↗

[The application of the gene-recombinated cell in the detection of PCBs compounds in environmental samples].

To develop novel and rapid bioassay systems for detection of PCBs in environmental and biological samples, two lines of gene-recombinated cells containing reporter gene, green fluorescent protein (GFP) and luciferase (Luc), were be chosen to detect the PCBs in the water, sediment and biological samples from environment. The result showed that the correlation between RFU of GFP and Luc activity and PCBs standard sample concentration was fine, r was 0.99188 and 0.98239 respectively. Compared with the instrument analysis with GC-ECD, the correlation between RFU of GFP and Luc activity and PCBs concentration in environmental and biological extracts was also fine. The method offered a new way of screening and semi-quantitative bioassay for PCBs compounds in environmental and biological samples.

Environmental Monitoring↗

Kinetic study of hydrated lime reaction with HCl.

Hydrochloride (HCl) is an acidic pollutant present in the flue gas of most municipal or hazardous waste incinerators. Hydrated lime (Ca(OH)2) is often used as a dry sorbent for injection in a spray reactor to remove HCI. However, due to the short residence time encountered, this control method has generally been found to have low conversion efficiencies which results in the high lime usage and generates large amount of fly ash as solid wastes. A fundamental study was carried outto investigate the kinetics of HCl-lime reaction under simulated flue gas conditions in order to better understand the process thereby providing a basis for an optimized lime usage and reduced fly ash production. The initial reaction rate and conversion of three limes were studied using a thermogravimetric analyzer by varying the gas flow rate, temperature (170-400 degrees C), and HCI concentrations (600-1200 mg/m3) as well as the associated particle size and surface area of the limes. The initial lime conversions were found to rely mostly on the residence time, while the ultimate lime conversions were strongly influenced by temperature and the reaction products. CaOHCI was found to be the primary product in most cases, while for one specific lime, CaCl2 was the ultimate conversion product after an extended time period. The true utilization of lime in flue gas cleanup is thus higher when CaOHCl is considered as the final product than those based on CaCl2 as the final product, which has been commonly used in previous studies. The initial reaction was controlled by diffusion of HCl in gas phase and the subsequent reaction by gaseous diffusion through the developing product layer. Increasing the HCI concentration raised the initial rate as well as conversion. However, overloading the lime with excessive HCI caused clogging at its surface and a drop in the ultimate conversion. Limes with smaller particle diameters and higher surface areas were found to be more reactive. The effect of gas-phase mass transfer was minimized when an optimum flow rate was chosen, and in the absence of internal diffusion the reaction was found to be first order with respect to HCI concentration.

Calcium Hydroxide↗

Control of mercury vapor emissions from combustion flue gas.

GOAL, SCOPE AND BACKGROUND: Mercury (Hg) emission from combustion flue gas is a significant environmental concern due to its toxicity and high volatility. A number of the research efforts have been carried out in the past decade exploiting mercury emission, monitoring and control from combustion flue gases. Most recently, increasing activities are focused on evaluating the behavior of mercury in coal combustion systems and developing novel Hg control technologies. This is partly due to the new regulatory requirement on mercury emissions from coal-fired combustors to be enacted under the U.S. Title III of the 1990 Clean Air Act Amendments. The aim of this review work is to better understand the state-of-the-art technologies of flue gas mercury control and identify the gaps of knowledge hence areas for further opportunities in research and development. MAIN FEATURES: This paper examines mercury behaviors in combustion systems through a comprehensive review of the available literature. About 70 published papers and reports were cited and studied. RESULTS AND DISCUSSION: This paper summarizes the mechanisms of formation of mercury containing compounds during combustion, its speciation and reaction in flue gas, as well as subsequent mobilization in the environment. It also provides a review of the current techniques designed for real-time, continuous emission monitoring (CEM) for mercury. Most importantly, current flue gas mercury control technologies are reviewed while activated carbon adsorption, a technology that offers the greatest potential for the control of gas-phase mercury emissions, is highlighted. CONCLUSIONS AND RECOMMENDATIONS: Although much progress has been achieved in the last decade, techniques developed for the monitoring and control of mercury from combustion flue gases are not yet mature and gaps in knowledge exist for further advancement. More R&D efforts are required for the effective control of Hg emissions and the main focuses are identified.

Air Pollutants↗

Kinetics and mechanisms of H2S adsorption by alkaline activated carbon.

Activated carbon adsorption is widely used to remove hydrogen sulfide (H2S), one of the major odorous compounds, from gas streams. In this study, the mechanisms of H2S adsorption by alkaline activated carbon were systematically studied. Two brands of commercial activated carbons were used as H2S adsorbents. A series of designed experiments were carried outto understand on a fundamental basis the differences in H2S removal capacity observed for the two types of carbons and samples for the same carbon obtained from different batches. The physicochemical and structural characteristics of the original and exhausted activated carbons were identified using several analytical approaches (i.e., XRF, SEM, XRD, and BET). The relationships between the adsorption performances of activated carbon for H2S and its physicochemical characteristics were discussed. The kinetics of the H2S adsorption was also studied using TGA/DSC system. Both physical adsorption and chemisorption played an important role in the H2S adsorption mechanisms with the studied carbons. Chemisorption was rapid and occurred mostly at the carbon surface whereas physical adsorption was relatively slow and mostly took place at the inner pores of carbon. Carbon II demonstrated the best performance of H2S removal due to its high capacity of both physical adsorption and chemisorption. Catalytic effects of transition metals might also contribute to enhancing the H2S oxidation.

Adsorption↗