Calculation of cerebral perfusion parameters using regional arterial input functions identified by factor analysis.

PURPOSE: To calculate regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and regional mean transit time (rMTT) accurately, an arterial input function (AIF) is required. In this study we identified a number of AIFs using factor analysis of dynamic studies (FADS), and performed the cerebral perfusion calculation pixel by pixel using the AIF that was located geometrically closest to a certain voxel. MATERIALS AND METHODS: To verify the robustness of the method, simulated images were generated in which dispersion or delay was added in some arteries and in the corresponding cerebral gray matter (GM), white matter (WM), and ischemic tissue. Thereafter, AIFs were determined using the FADS method and simulations were performed using different signal-to-noise ratios (SNRs). Simulations were also carried out using an AIF from a single pixel that was manually selected. In vivo results were obtained from normal volunteers and patients. RESULTS: The FADS method reduced the underestimation of rCBF due to dispersion or delay that often occurs when only one AIF represents the entire brain. CONCLUSION: This study indicates that the use of FADS and the nearest-AIF method is preferable to manual selection of one single AIF.

Adult↗

Denoising of complex MRI data by wavelet-domain filtering: application to high-b-value diffusion-weighted imaging.

The Rician distribution of noise in magnitude magnetic resonance (MR) images is particularly problematic in low signal-to-noise ratio (SNR) regions. The Rician noise distribution causes a nonzero minimum signal in the image, which is often referred to as the rectified noise floor. True low signal is likely to be concealed in the noise, and quantification is severely hampered in low-SNR regions. To address this problem we performed noise reduction (or denoising) by Wiener-like filtering in the wavelet domain. The filtering was applied to complex MRI data before construction of the magnitude image. The noise-reduction algorithm was applied to simulated and experimental diffusion-weighted (DW) images. Denoising considerably reduced the signal standard deviation (SD, by up to 87% in simulated images) and decreased the background noise floor (by approximately a factor of 6 in simulated and experimental images).

Algorithms↗

Comparison of contrast agents with high molarity and with weak protein binding in cerebral perfusion imaging at 3 T.

PURPOSE: To examine and compare properties of high-molarity contrast agent gadobutrol (Gadovist) and weakly protein-binding agent gadobenate-dimeglumine (MultiHance in dynamic susceptibility contrast (DSC) perfusion imaging at 3 T. MATERIALS AND METHODS: Sixteen healthy volunteers underwent three separate examinations with contrast agent doses of 0.1 and 0.2 mmol/kg body weight (bw) gadobutrol and 0.1 mmol/kg bw gadobenate-dimeglumine. Maps of relative regional cerebral blood volume (rCBV) and blood flow (rCBF) were calculated using deconvolution based on singular value decomposition. Signal and concentration time curves, the concentration-to-noise ratio (SNR(c)), and gray matter (GM)-to-white matter (WM) rCBV and rCBF contrast and ratios were evaluated in a region of interest (ROI)-based analysis. Image quality of calculated parametric maps was assessed in direct visual comparison and with respect to suitability for diagnostic purposes. RESULTS: The contrast agents displayed very similar results in the 0.1 mmol/kg examinations, both with respect to the quantitative evaluation parameters and in the qualitative assessment of the calculated parametric maps. Maps from 0.2 mmol/kg examinations were rated as being superior in quality, but with respect to diagnostic suitability all contrast agents and doses yielded images of sufficient quality. CONCLUSION: At 3 T, a gadobutrol or gadobenate-dimeglumine dose of 0.1 mmol/kg is sufficient for DSC magnetic resonance imaging (MRI) perfusion assessment. At the used small injection volumes, the tissue concentration curve was determined only by the gadolinium (Gd) dosage in mmol/kg, and the T2* relaxation effects of the two agents can be considered to be nearly identical in the applied gradient-echo (GRE) sequence.

Adult↗

Aspects on the accuracy of cerebral perfusion parameters obtained by dynamic susceptibility contrast MRI: a simulation study.

Several studies have indicated that deconvolution based on singular value decomposition (SVD) is a robust concept for retrieval of cerebral blood flow in dynamic susceptibility contrast (DSC) MRI. However, the behavior of the technique under typical experimental conditions has not been completely investigated. In the present study, cerebral perfusion was simulated using different temporal resolutions, different signal-to-noise ratios (S/Ns), different shapes of the arterial input function (AIF), different signal drops, and different cut-off levels in the SVD deconvolution. Using Zierler's area-to-height relationship in combination with the central volume theorem, calculations of regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and regional mean transit time (rMTT) were accomplished, based on simulated DSC-MRI signal curves corresponding to artery, gray matter (GM), white matter (WM), and ischemic tissue. Gaussian noise was added to the noise-free signal curves to generate different S/Ns. We studied image time intervals of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 s, as well as different degrees of signal decrease. The singular-value threshold in the SVD procedure and the shape of the AIF were also varied. Increased rCBF was seen when noise was added, especially for rCBF in WM at the larger image time intervals. The rCBF showed large standard deviations using a low threshold value. A prolonged time interval led to a lower absolute value of rCBF both in GM and WM, and a low/broad AIF also underestimated the rCBF. When a larger maximal signal decrease was assumed, smaller standard deviations were observed. No systematic change of the average rCBV was observed with increasing noise or with increasing image time interval. At S/N = 40, a low cut-off value resulted in an rCBF that was closer to the true value. Furthermore, at low S/N it was difficult to differentiate ischemic tissue from WM.

Brain↗

Combined diffusion weighting and CSF suppression in functional MRI.

In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal-to-noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 +/- 73 pixels (mean +/- SD) using the standard EPI pulse sequence, 31 +/- 12 pixels using IR-EPI and 15 +/- 13 pixels when DW-IR-EPI was employed. The relative signal increase was 5.7 +/- 1.1% using standard EPI, 11.5 +/- 3.1% using IR-EPI and 9.9 +/- 2.4% using DW-IR-EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 +/- 50 pixels using the standard EPI, and when using IR-EPI, the activated volume was 28 +/- 13 pixels. At equal S/N, the signal increase was 7.3 +/- 1.4% using standard EPI and 12.0 +/- 3.6% using IR-EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels.

Adult↗