PubMed Health⌕ Search

Biomedical subjects

Ross Franklin

Publications and source records attributed to Ross Franklin.

3 recordsLinked to original sources

Computer simulation of visual outcomes of wavefront-only corneal ablation.

PURPOSE: To evaluate the effectiveness, predicted visual outcome, and limitations of a corneal ablation algorithm that uses wavefront aberration measurement alone without the need for corneal shape information. SETTING: Contact Lens and Visual Optical Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Australia. METHODS: Corneal topography and wavefront error data from 22 eyes of 11 potential refractive surgery candidates were used. A computer simulation of the corneal ablation was performed, and the predicted postoperative visual outcome was assessed by calculating the resulting wavefront root-mean-square (RMS) values and visual Strehl ratios. Additionally, the effect of ablation alignment error was examined. Finally, the visual outcomes of the wavefront-only corneal ablations were compared to those in an age-matched group of 20 emmetropic patients. RESULTS: Significant improvement in total and higher-order wavefront RMS was achieved postoperatively in both an ideal setting and in the case of ablation alignment errors. The predicted improvement in visual Strehl ratio in the potential refractive surgery candidates was significantly better than that in the untreated emmetropes. After additional simulated decentration of the pupil center by 150 microm, the result was slightly worse, but the change was found to not be significant when compared to the retinal image quality of emmetropes. CONCLUSIONS: Wavefront-only corneal ablation algorithms could potentially lead to significantly better visual outcomes than those normally encountered in untreated emmetropes, provided that the alignment error is not large. The presented methodology may be used as a screening tool to predict patients' visual outcomes before the surgery.

Adolescent↗

Optical considerations in the contact lens correction of infant aphakia.

BACKGROUND: Correction of infant aphakia with conventional soft and rigid designs induces significant amounts of positive spherical aberration. METHODS: Different levels of positive spherical aberration were induced by rigid lenses positioned close to the eye. Visual acuity and depth of focus were measured for twelve young adult subjects. RESULTS: Positive spherical aberration acts to produce an increase in relative depth of focus, but because of the reduction of best visual acuity, there is a concurrent decrease in absolute depth of focus. As the spherical aberration increases, there is a progressive loss of best-corrected visual acuity. CONCLUSIONS: The correction of spherical aberration in contact lenses for infant aphakia provides the best theoretical optical conditions for normal ocular growth and visual development. We provide examples of the optimal aspheric surfaces to minimize spherical aberration in contact lenses for infant aphakes.

Adult↗

Automatic estimation of the corneal limbus in videokeratoscopy.

An algorithm for estimating the corneal limbus from videokeratoscopic images is proposed. After the image is transformed to a polar grid, a novel edge-detection procedure, suitable for the detection of the soft edge produced by the limbus, is used to locate the limbus. Outliers due to the eyelids, eyelashes, and videokeratoscopic rings are removed by taking advantage of the approximate circularity of the cornea. An ellipse which minimizes the sum of the squared algebraic errors is fitted to the remaining edge points. Comparisons between the proposed algorithm, a manual computer-based technique and an algorithm which uses conventional edge-detection techniques demonstrate the accuracy of the proposed algorithm.

Algorithms↗