Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis.

OBJECTIVES: Although bone loss around implants is reported as a complication when it progresses uncontrolled, resorption does not always lead to implant loss, but may be the result of biomechanical adaptation to stress. To verify this hypothesis, a three-dimensional finite element analysis was performed and the influence of marginal bone resorption amount and shape on stress in the bone and implant was investigated. MATERIAL AND METHODS: A total of nine bone models with an implant were created: a non-resorption (Base) model and eight variations, in which three different resorption depths were combined with pure vertical or conical (vertical-horizontal) resorption. Axial and buccolingual forces were applied independently to the occlusal node at the center of the superstructure. RESULTS: Regardless of load direction, bone stresses were higher in the pure vertical resorption (A) models than in the Base model, and increased with resorption depth. However, cortical bone stress was much lower in the conical resorption models than in both the Base and A models of the same resorption depth. An opposite tendency was observed in the cancellous bone under buccolingual load. Under buccolingual load, highest stress in the implant increased linearly with the resorption depth for all the models and its location approached the void existing below the abutment screw. CONCLUSIONS: The results of this analysis suggest that a certain amount of conical resorption may be the result of biomechanical adaptation of bone to stress. However, as bone resorption progresses, the increasing stresses in the cancellous bone and implant under lateral load may result in implant failure.

Adaptation, Physiological↗

Fatigue resistance of two implant/abutment joint designs.

STATEMENT OF PROBLEM: Because of reported mechanical failures, alternative implant system components with suggested optimized strength have been manufactured. However, the endurance of these products has not been well investigated. PURPOSE: This study was designed to assess the effect of joint design on the fatigue strength and failure mode of 2 single-tooth implant systems: Brånemark and ITI, in which a hex mediated-butt joint and 8-degree internal conical implant/abutment interface are used, respectively. MATERIALS AND METHODS: Seven 10-mm implants from each implant system were embedded to a depth of 7 mm in cylindrical acrylic resin blocks. CeraOne and Solid abutments with cement-retained castings were assembled to the Brånemark and ITI implants, respectively. The assembled units were mounted in a lever-type-testing machine that was equipped with an automatic counting device and shutoff sensors, enabling the recording of the number of cycles till failure. A cyclic load of 100 N was applied perpendicular to the long axis of the assemblies at a rate of 75 cycles/min. To investigate specimen resistance to fatigue during 6 years of simulated function, a target of 1,800,000 cycles was defined. Specimen preparation and testing was performed by the same operator. The association of the joint design with the occurrence of failure was verified by Fisher's exact probability test (P<.05). RESULTS: For the Brånemark group, the gold alloy abutment screw in all specimens fractured between 1,178,023 and 1,733,526 cycles with a standard deviation of 224,477 cycles. For the ITI group, all specimens had no failure until 1,800,000 cycles. Statistical analysis showed a highly significant difference between the 2 groups (P=.000582). CONCLUSIONS: Within the limitations of this in vitro study, the effect of joint design on the fatigue strength and failure mode of the ITI single tooth implant system was significantly better (P>.001) than the Brånemark single-tooth implant system tested.

Cementation↗

Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.

PURPOSE: A 3-dimensional finite element analysis was performed to evaluate the influence of implant type and length, as well as that of bone quality, on the stress/strain in bone and implant. MATERIALS AND METHODS: Two types (screw and cylinder) and 4 lengths (9.2, 10.8, 12.4, and 14.0 mm) of titanium implants were buried in 4 types of bone modeled by varying the elastic modulus for cancellous bone. Axial and buccolingual forces were applied to the occlusal node at the center of the abutment. RESULTS: Regardless of load direction, maximum equivalent stress/strain in bone increased with a decrease in cancellous bone density. Under axial load, especially in the low-density bone models, maximum equivalent strain in cancellous bone was lower with the screw-type implant than with the cylinder-type implant. It was also lower with the longer implants than with the shorter implants. Under buccolingual load, equivalent stress/strain was influenced mainly by bone density. DISCUSSION: This study confirms the importance of bone quality and its presurgical diagnosis for implant long-term prognosis. Implant length and type can also influence bone strain, especially in low-density bone. CONCLUSIONS: The results of this study suggest that cancellous bone of higher rather than lower density might ensure a better biomechanical environment for implants. Moreover, longer screw-type implants could be a better choice in a jaw with cancellous bone of low density.

Biomechanical Phenomena↗

Influence of superstructure materials on strain around an implant under 2 loading conditions: a technical investigation.

PURPOSE: This investigation was concerned with the effect of 3 superstructure materials on the strain around an implant under static and nonimpact dynamic loading. MATERIALS AND METHODS: Five highly filled composite resin-veneered crown analogs, 5 autopolymerized acrylic resin-veneered crown analogs, and 5 gold-alloy full cast crown analogs were prepared. The resin veneers were applied to gold-alloy frameworks. These crown analogs were prepared to fit an ITI implant-abutment assembly, which was screwed into a block of acrylic resin to simulate implantation in bone. The crown analogs were successively placed on the abutment, and a lateral load of 100 N was applied to the superstructure by a lever-type testing machine. Strains were recorded under static and dynamic loading by a 2mm-long strain gauge bonded to the surface of the bone simulant tangential to the implant. The dynamic load simulated masticatory cycles (75 strokes/min). RESULTS: Although the strain values differed significantly between the static and dynamic loading (P < .05), there was no significant difference among the superstructure materials under either loading condition (P > .05). DISCUSSION: These findings are in agreement with in vivo measurements, thus suggesting that cyclic rather than impact loading should be used in the investigation of occlusal material behavior under functional loading. CONCLUSION: Under static and nonimpact dynamic loading, the 3 superstructure materials tested (highly filled composite resin, acrylic resin, and gold alloy) had the same influence on the strain transmitted to a bone simulant that surrounded a single implant.

Acrylic Resins↗

Peri-implant stress analysis in simulation models with or without trabecular bone structure.

Most 3-dimensional (3D) finite element analyses (FEAs) simplify the cancellous bone to a block and completely ignore its trabecular structure. Thus, a 3D FEA was performed to compare the peri-implant stress distribution of a model in which the trabecular structure was accurately simulated (precise model) with that of a model with a homogenous cancellous bone component (simplified model). In contrast to the simplified model, the distribution patterns and higher stresses in the precise model may explain the overall bone resorption at the implant-bone interface in load-related implant failures. Further studies using data from the jawbone and a more detailed implant simulation are planned.