PubMed Health⌕ Search

Biomedical subjects

Roy W Beck

Publications and source records attributed to Roy W Beck.

41 records · Page 3Linked to original sources

A randomized trial of prescribed patching regimens for treatment of severe amblyopia in children.

OBJECTIVE: To compare full-time patching (all hours or all but 1 hour per day) to 6 hours of patching per day, as prescribed treatments for severe amblyopia in children younger than 7 years. DESIGN: Prospective, randomized multicenter clinical trial (32 sites). PARTICIPANTS: One hundred seventy-five children younger than 7 years with amblyopia in the range of 20/100 to 20/400. INTERVENTION: Randomization either to full-time patching or to 6 hours of patching per day, each combined with at least 1 hour of near-visual activities during patching. MAIN OUTCOME MEASURE: Visual acuity in the amblyopic eye after 4 months. RESULTS: Visual acuity in the amblyopic eye improved a similar amount in both groups. The improvement in the amblyopic eye acuity from baseline to 4 months averaged 4.8 lines in the 6-hour group and 4.7 lines in the full-time group (P = 0.45). CONCLUSION: Six hours of prescribed daily patching produces an improvement in visual acuity that is of similar magnitude to the improvement produced by prescribed full-time patching in treating severe amblyopia in children 3 to less than 7 years of age.

Amblyopia↗

A computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol.

PURPOSE: To develop a computerized method of visual acuity testing for clinical research as an alternative to the standard Early Treatment for Diabetic Retinopathy Study (ETDRS) testing protocol, and to evaluate its test-retest reliability and concordance with standard ETDRS testing. DESIGN: Test-retest reliability study. METHODS: Multicenter setting of a study population of 265 patients at three clinical sites. Visual acuity was measured with both the electronic visual acuity testing algorithm (E-ETDRS) and standard ETDRS protocol (S-ETDRS) twice on one eye of each patient. E-ETDRS testing was conducted using the electronic visual acuity tester (EVA), which utilizes a programmed Palm (Palm, Inc, Santa Clara, California, USA) hand-held device communicating with a personal computer and 17-inch monitor at a test distance of 3 meters. RESULTS: For the E-ETDRS protocol, test-retest reliability was high (r = 0.99; with 89% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial tests, respectively) and comparable with that of S-ETDRS testing (r = 0.99; with 87% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial test, respectively). The E-ETDRS and S-ETDRS scores were highly correlated (r = 0.96 for initial tests and r = 0.97 for repeat tests). Based on estimates of 95% confidence intervals, a change in visual acuity of 0.2 logMAR (10 letters) from a baseline level is unlikely to be related to measurement variability using either the E-ETDRS or the S-ETDRS visual acuity testing protocol. CONCLUSIONS: The E-ETDRS protocol has high test-retest reliability and good concordance with S-ETDRS testing. The computerized method has advantages over the S-ETDRS testing in electronically capturing the data for each tested letter, requiring only a single distance for testing from 20/12 to 20/800, potentially reducing testing time, and potentially decreasing technician-related bias.

Adolescent↗

Reliability of the electronic early treatment diabetic retinopathy study testing protocol in children 7 to <13 years old.

PURPOSE: To assess the test-retest reliability of the electronic Early Treatment Diabetic Retinopathy Study (E-ETDRS) visual acuity algorithm using the computerized Electronic Visual Acuity (EVA) tester in children 7 to <13 years old. DESIGN: Test-retest reliability study. METHODS: This multicenter study involved 245 subjects at four clinical sites. As the main outcome measure, visual acuity was measured twice using the E-ETDRS testing protocol on the EVA system, which uses a programmed handheld device to communicate with a personal computer and a 17-inch monitor at a 3-m test distance. RESULTS: Test-retest reliability was high (r =.94 for right eyes and 0.96 for left eyes) and for both right and left eyes, 89% of retest scores were within 0.1 logarithm of the minimal angle of resolution (logMAR) (five letters) of the initial test score and 99% of retests were within 0.2 logMAR (10 letters). Reliability was high across the age range of 7 to <13 years. Based on 95% confidence level estimates, a change in visual acuity of 0.2 logMAR (10 letters) from a previous acuity measure is unlikely to result from measurement variability. CONCLUSIONS: The E-ETDRS protocol using the EVA has high test-retest reliability in children 7 to <13 years of age. Potential advantages include better standardization across multiple sites, the ability to directly capture data electronically with an automatic acuity score calculation, the reduction of potential bias by limiting the tester's role, and the requirement of only a single testing distance for measurements from 20/800 to 20/12. This computerized testing method should be considered when visual acuity is used as an outcome measure in eye research involving children 7 to <13 years old.

Adolescent↗

Interferon beta-1a for early multiple sclerosis: CHAMPS trial subgroup analyses.

The objective of this work was to assess the effect of interferon beta-1a (Avonex) on the rate of development of clinically definite multiple sclerosis and brain magnetic resonance imaging changes in subgroups based on type of presenting event, baseline brain magnetic resonance imaging parameters, and demographic factors in the Controlled High-Risk Subjects Avonex Multiple Sclerosis Prevention Study (CHAMPS) trial. After the onset of a first demyelinating event, 383 patients with brain magnetic resonance imaging evidence of subclinical demyelination were treated with corticosteroids and randomly assigned to receive weekly intramuscular injections of 30 microg interferon beta-1a or placebo. The treatment effect within subgroups was assessed in proportional hazards models both for the development of clinically definite multiple sclerosis and for a combined outcome of development of clinically definite multiple sclerosis or >1 new or enlarging T2 lesions on brain magnetic resonance imaging. A beneficial effect of treatment was noted in all subgroups evaluated. Adjusted rate ratios for the development of clinically definite multiple sclerosis in the optic neuritis, brainstem-cerebellar, and spinal cord syndrome subgroups were 0.58 (p = 0.05), 0.40 (p = 0.03), and 0.30 (p = 0.01) and for the development of the combined clinically definite multiple sclerosis/magnetic resonance imaging outcome were 0.50 (p < 0.001), 0.41 (p = 0.001), and 0.40 (p = 0.004), respectively. A treatment benefit on both outcome measures also was seen in subgroups based on baseline brain magnetic resonance imaging parameters, gender, and age. Interferon beta-1a is beneficial when initiated at the first clinical demyelinating event in patients with brain magnetic resonance imaging evidence of subclinical demyelination. The beneficial effect is present for optic neuritis, brainstem-cerebellar syndromes, and spinal cord syndromes.

Adjuvants, Immunologic↗

Clinical research in pediatric ophthalmology: the Pediatric Eye Disease Investigator Group.

The Pediatric Eye Disease Investigator Group (PEDIG) is a network of university-based and community-based pediatric eye care practitioners that is conducting multiple clinical research studies. The group has conducted the Congenital Esotropia Observational Study, which assessed the early course of esotropia in infants, and the Amblyopia Treatment Studies, a series of randomized trials, the first of which compared atropine and patching for treatment of moderate amblyopia in children 3 to <7 years old. Herein, the results of these studies are summarized, and the current and future studies of the group are described.

Amblyopia↗