Phase transition in random catalytic networks.

The notion of (auto)catalytic networks has become a cornerstone in understanding the possibility of a sudden dramatic increase of diversity in biological evolution as well as in the evolution of social and economical systems. Here we study catalytic random networks with respect to the final outcome diversity of products. We show that an analytical treatment of this long-standing problem is possible by mapping the problem onto a set of nonlinear recurrence equations. The solution of these equations shows a crucial dependence of the final number of products on the initial number of products and the density of catalytic production rules. For a fixed density of rules we can demonstrate the existence of a phase transition from a practically unpopulated regime to a fully populated and diverse one. The order parameter is the number of final products. We are able to fully understand the origin of this phase transition as a crossover from one set of solutions from a quadratic equation to the other. We observe a remarkable similarity of the solution of the system and the PVT diagrams in standard thermodynamics.

Algorithms↗

Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

PURPOSE: We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS: Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was defined on CT images, the position of the phantom was recorded by an optical tracking system. Positional data about the phantom and the corresponding CT image was transferred to the robot planning system (Linux-based industrial PC equipped with video capture card). Once the appropriate position, angulation, and pitch were calculated, the robotic arm moved automatically with 7 degrees-of-freedom to the planned insertion path, aiming the needle-trajectory at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured and short cut pieces of a guidewire were pushed into the target to evaluate the deviation of the actual needle track from the target. RESULTS: In all targets, biopsy specimens (mean length 5.6+/-1.4 mm) were harvested with only 1 needle pass required. The mean deviation of the needle tip from the center of the target in the x and z axes was 1.2+/-0.9 mm and 0.6+/-0.4 mm, respectively. CONCLUSIONS: Robotic-assisted biopsies in vitro, using CT guidance, were feasible and provided high accuracy.

Biopsy↗

Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.

The purpose of this study was to develop a robotic system for ultrasound (US)-guided biopsy and to validate the feasibility, accuracy and efficacy using phantom tests. Twenty peas (mean diameter 9.3+/-0.1 mm) embedded within a gel-phantom were selected for biopsy. Once the best access was defined, the position of the US transducer was recorded by an optical tracking system. Positional data of the transducer and the corresponding US image were transferred to the roboter planning system (LINUX-based industrial PC equipped with video capture card). Once the appropriate position, angulation and pitch were calculated, the robotic arm moved automatically with seven degrees-of-freedom to the planned insertion path, aiming the needle-positioning unit at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured, and the deviation of the actual needle tract from the center of the target was evaluated sonographically. In all targets, the biopsy specimen (mean length 5+/-1.2 mm) was harvested with only one needle pass required The mean deviation of the needle tip from the center of the target was 1.1+/-0.8 mm. Robotic assisted biopsies in-vitro using US-guidance were feasible and provided high accuracy.

Biopsy↗

Computer-enhanced stereoscopic vision in a head-mounted operating binocular.

Based on the Varioscope, a commercially available head-mounted operating binocular, we have developed the Varioscope AR, a see through head-mounted display (HMD) for augmented reality visualization that seamlessly fits into the infrastructure of a surgical navigation system. We have assessed the extent to which stereoscopic visualization improves target localization in computer-aided surgery in a phantom study. In order to quantify the depth perception of a user aiming at a given target, we have designed a phantom simulating typical clinical situations in skull base surgery. Sixteen steel spheres were fixed at the base of a bony skull, and several typical craniotomies were applied. After having taken CT scans, the skull was filled with opaque jelly in order to simulate brain tissue. The positions of the spheres were registered using VISIT, a system for computer-aided surgical navigation. Then attempts were made to locate the steel spheres with a bayonet probe through the craniotomies using VISIT and the Varioscope AR as a stereoscopic display device. Localization of targets 4 mm in diameter using stereoscopic vision and additional visual cues indicating target proximity had a success rate (defined as a first-trial hit rate) of 87.5%. Using monoscopic vision and target proximity indication, the success rate was found to be 66.6%. Omission of visual hints on reaching a target yielded a success rate of 79.2% in the stereo case and 56.25% with monoscopic vision. Time requirements for localizing all 16 targets ranged from 7.5 min (stereo, with proximity cues) to 10 min (mono, without proximity cues). Navigation error is primarily governed by the accuracy of registration in the navigation system, whereas the HMD does not appear to influence localization significantly. We conclude that stereo vision is a valuable tool in augmented reality guided interventions.

Depth Perception↗

Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery.

We developed a head-mounted display (HMD) with integrated computer-generated stereoscopic projection of target structures and integrated it into visit, a specific oral implant planning and navigation software. The HMD is equipped with two miniature computer monitors that project computer-generated graphics stereoscopically into the optical path. Its position is tracked by the navigation system's optical tracker and target structures are displayed in their true position over the operation site. In order to test this system's accuracy and spatial perception of the viewer, five interforaminal implants in three dry human mandibles were planned with visit and executed using the stereoscopic projection through the HMD. The deviation between planned and achieved position of the implants was measured on corresponding computed tomography (CT) scan images recorded post-operatively. The deviation between planned and achieved implant position at the jaw crest was 0.57 +/- 0.49 mm measured from the lingual, and 0.58 +/- 0.4 mm measured from the buccal cortex. At the tip of the implants the deviation was 0.77 +/- 0.63 mm at the lingual and 0.79 +/- 0.71 mm at the buccal cortex. The mean angular deviation between planned and executed implant position was 3.55 +/- 2.07 degrees. The present in vitro experiment indicates that the concept of preoperative planning and transfer to the operative field by an HMD allows us to achieve an average precision within 1 mm (range up to 3 mm) of the implant position and within 3 degrees deviation for the implant inclination (range up to 10 degrees ). Control during the drilling procedure is significantly improved by stereoscopic vision through the HMD resulting in a more accurate inclination of the implants.

Computer Graphics↗

A head-mounted operating binocular for augmented reality visualization in medicine--design and initial evaluation.

Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 +/- 0.38 pixels or 0.12 +/- 0.05 mm for a 640 x 480 display. Maximum error accounted for 3.33 +/- 1.04 pixels or 0.33 +/- 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

Calibration↗