Functional conformational motions in the turnover cycle of cholesterol oxidase.

Reexamining experimental data of single-molecule fluorescence correlation spectroscopy for cholesterol oxidase, we find that the existing Michaelis-Menten models with dynamical disorder cannot explain strong correlations between subsequent turnover cycles revealed in the diagonal feature in the joint statistical distribution of adjacent "on" times of this enzyme. We suggest that functional conformational motions representing ordered sequences of transitions between a set of conformational substates are involved, along with equilibrium conformational fluctuations in the turnover cycle of cholesterol oxidase. A two-channel model of single-enzyme dynamics, including a slow functional conformational motion in one of the channels, is proposed that allows us to reproduce such strong correlations.

Cholesterol Oxidase↗

CD8 kinetically promotes ligand binding to the T-cell antigen receptor.

The mechanism of CD8 cooperation with the TCR in antigen recognition was studied on live T cells. Fluorescence correlation measurements yielded evidence of the presence of two TCR and CD8 subpopulations with different lateral diffusion rate constants. Independently, evidence for two subpopulations was derived from the experimentally observed two distinct association phases of cognate peptide bound to class I MHC (pMHC) tetramers and the T cells. The fast phase rate constant ((1.7 +/- 0.2) x 10(5) M(-1) s(-1)) was independent of examined cell type or MHC-bound peptides' structure. Its value was much faster than that of the association of soluble pMHC and TCR ((7.0 +/- 0.3) x 10(3) M(-1) s(-1)), and close to that of the association of soluble pMHC with CD8 ((1-2) x 10(5) M(-1) s(-1)). The fast binding phase disappeared when CD8-pMHC interaction was blocked by a CD8-specific mAb. The latter rate constant was slowed down approximately 10-fold after cells treatment with methyl-beta-cyclodextrin. These results suggest that the most efficient pMHC-cell association route corresponds to a fast tetramer binding to a colocalized CD8-TCR subpopulation, which apparently resides within membrane rafts: the reaction starts by pMHC association with the CD8. This markedly faster step significantly increases the probability of pMHC-TCR encounters and thereby promotes pMHC association with CD8-proximal TCR. The slow binding phase is assigned to pMHC association with a noncolocalized CD8-TCR subpopulation. Taken together with results of cytotoxicity assays, our data suggest that the colocalized, raft-associated CD8-TCR subpopulation is the one capable of inducing T-cell activation.

Antibodies, Monoclonal↗

Ultrasensitive reporter protein detection in genetically engineered bacteria.

We demonstrate the use of laser-induced fluorescence confocal spectroscopy to measure analyte-stimulated enhanced green fluorescent protein (egfp) synthesis by genetically modified Escherichia coli bioreporter cells. Induction is measured in cell lysates and, since the spectroscopic focal volume is approximately the size of one bioreporter cell, also in individual live bacteria. This is, to our knowledge, the first ever proof-of-concept work utilizing instrumentation with single-molecule detection capability to monitor bioreporter response. Although we use arsenic inducible bioreporters here, the method is extensible to gfp/egfp bioreporters that are responsive to other substances.

Arsenites↗

Fluorescence correlation spectroscopy of molecular motions and kinetics.

The foundations for fluorescence correlation spectroscopy (FCS) were already laid in the early 1970s, but this technique did not become widely used until single-molecule detection was established almost 20 years later with the use of diffraction-limited confocal volume element. The analysis of molecular noise from the GHz- to the Hz-region facilitates measurements over a large dynamic range covering photophysics, conformational transitions and interactions as well as transport properties of fluorescent biomolecules. From the Poissonian nature of the noise spectrum the absolute number of molecules is obtainable. Originally used for the analysis of molecular interactions in solutions, the strength of FCS lies also in its applicability to molecular processes at either the surface or interior of single cells. Examples for the analysis of surface kinetics including on and off rates of ligand-receptor interactions will be given. The possibility of obtaining this type of information by FCS will be of particular interest for cell-based drug screening.

Kinetics↗

Visualization of a functionally enhanced GFP-tagged galanin R2 receptor in PC12 cells: constitutive and ligand-induced internalization.

Trafficking of the galanin R2 receptor (GALR2) fused with enhanced GFP (EGFP) was studied by using confocal fluorescence microscopy. The fusion protein was predominantly localized on the plasma membrane with some intracellular fluorescent structures (vesicles), mainly in the perinuclear region. Incubation with galanin resulted in a concentration-dependent increase in intracellular Ca2+ concentration levels, suggesting that the GALR2-EGFP conjugate is functional. After blocking endocytosis with methyl-beta-cyclodextrin GALR2-EGFP expression was increased on the surface and decreased in the cytoplasm. Blocking endocytic recycling with monensin caused an increase of intracellular GALR2-EGFP accumulation and a decrease of fluorescence on the plasma membrane. GALR2-EGFP on the plasma membrane was internalized within 5-10 min after treatment with galanin or AR-M1896, a selective GALR2 agonist, with a dramatic reduction in plasma membrane localization and appearance in intracellular vesicles. Neither M35 nor M40, two galanin analogues with putative antagonistic action, prevented GALR2 agonist-induced internalization of GALR2-EGFP, suggesting that they are not antagonists at this receptor under the present circumstances. Galanin stimulation at low temperature caused GALR2-EGFP aggregation and clustering on the surface but no translocation to cytoplasm. After coincubation with galanin the GALR2-EGFP was colocalized with internalized Texas red-transferrin, a marker of the clathrin endocytic pathway. Hyperosmotic sucrose inhibited internalization of GALR2-EGFP. Taken together these findings indicate that GALR2 undergoes constitutive endocytosis and recycling and that both ligand-independent and ligand-dependent internalization use the clathrin-dependent endocytic recycling pathway.

Animals↗

Direct quantification of mRNA expression levels using single molecule detection.

Determination of the gene expression by direct quantification of mRNA is becoming increasingly important in basic, pharmaceutical and clinical research. We present a novel approach for gene quantification based on direct hybridization of gene-specific probes to target mRNA sequences in solution at temperatures ensuring absolute specificity of the probe-target complex. No enzymatic steps like reverse transcription or amplification by PCR are involved within the quantification process. In order to increase specificity as well as sensitivity, two probes emitting fluorescence light in different colors are used for our homogeneous assay using fluorescence cross-correlation. We relate to the single molecule sensitivity of excitation and detection in confocal cavities avoiding the amplification of the detected signal. The analysis of the expression level of high, medium and low abundant genes is described in two different cell lines, whereby the genes are quantified in absolute numbers.

Calcium-Binding Proteins↗

Direct gene expression analysis.

The direct analysis of single biological molecules is getting increasingly important in basic as well as pharmaceutical research (e.g. for gene expression analysis). In particular single-molecule fluorescence detection provides exciting new opportunities to probe biochemical processes in unprecedented detail. Currently several academic and industrial research groups work on the development of single molecule detection based technologies in order to directly detect and analyze RNA and DNA molecules. As these developed methods are characterized as homogenous assays and obviate any amplification of the target or the signal, they provide clear advantages compared to methods like real-time PCR or DNA- arrays. In the following we describe a recently developed approach based on fluorescence correlation spectroscopy (FCS). This expression assay is based on gene-specific hybridization of two dye-labeled DNA probes to a selected target molecule (either DNA or RNA) in solution. The subsequent dual color cross-correlation analysis allows the quantification of the bio-molecule of interest in absolute numbers. Target concentrations of less than 10(-12) M can be easily monitored, covering the direct analysis of the expression levels of high, medium and low abundant genes.

Animals↗

Gene expression analysis using single molecule detection.

Recent developments of single molecule detection techniques and in particular the introduction of fluorescence correlation spectroscopy (FCS) led to a number of important applications in biological research. We present a unique approach for the gene expression analysis using dual-color cross-correlation. The expression assay is based on gene-specific hybridization of two dye-labeled DNA probes to a selected target gene. The counting of the dual-labeled molecules within the solution allows the quantification of the expressed gene copies in absolute numbers. As detection and analysis by FCS can be performed at the level of single molecules, there is no need for any type of amplification. We describe the gene expression assay and present data demonstrating the capacity of this novel technology. In order to prove the gene specificity, we performed experiments with gene-depleted total cDNA. The biological application was demonstrated by quantifying selected high, medium and low abundant genes in cDNA prepared from HL-60 cells.

Actins↗

Parallel flow measurements in microstructures by use of a multifocal 4 x 1 diffractive optical fan-out element.

We have developed a multifocal optical fluorescence correlation spectroscopy system for parallel flow analyses. Multifocal excitation was made possible through a 4 x 1 diffractive optical fan-out element, which produces uniform intensity in all four foci. Autocorrelation flow analyses inside a 20 microm x 20 microm square microchannel, with the 4 x 1 fan-out foci perpendicular to the flow direction, made it possible to monitor different flows in all four foci simultaneously. We were able to perform cross-correlation flow analyses by turning the microstructure, thereby having all four foci parallel to the direction of flow. Transport effects of the diffusion as a function of flow and distance could then also be studied.

Fluorescent Dyes↗

Parallel fluorescence detection of single biomolecules in microarrays by a diffractive-optical-designed 2 x 2 fan-out element.

We have developed a multifocal diffractive-optical fluorescence correlation spectroscopy system for parallel excitation and detection of single tetramethylrhodamine biomolecules in microarrays. Multifocal excitation was made possible through the use of a 2 x 2 fan-out diffractive-optical element with uniform intensity in all foci. Characterization of the 2 x 2 fan-out diffractive-optical element shows formation of almost perfect Gaussian foci of submicrometer lateral diameter, as analyzed by thermal motion of tetramethylrhodamine dye molecules in solution. Results of parallel excitation and detection in a high-density microarray of circular wells show single-biomolecule sensitivity in all four foci simultaneously.

Lasers↗

Ligand binding of a ribosome-displayed protein detected in solution at the single molecule level by fluorescence correlation spectroscopy.

Interaction of a single-chain antibody fragment (scFv) with its cognate antigen while still attached to the ribosome was studied by fluorescence correlation spectroscopy (FCS). In experiments with purified scFv, FCS was capable of resolving the difference in diffusion time between free and antibody-bound labelled antigen. Ribosome-displayed antibody fragments generated by in vitro translation, in which neither the protein nor the mRNA leaves the ribosome owing to the absence of a stop codon and stabilizing buffer conditions, could be shown to specifically bind the antigen. The antibody-antigen interaction was specific, as shown by inhibition or displacement with unlabelled antigen and by control experiments with a non-cognate antibody fragment.

Amino Acid Sequence↗

Brownian motion of single molecules in electric fields.

The behavior of negatively charged single rhodamine-labeled molecules excited to fluorescence in confocal volume elements has been investigated in oscillating voltage gradients between 1 and 15 kV/cm. The effective charge of rhodamin labeled deoxy-uridine triphosphate (Rh-dUTP) is dependent on the field strength applied and likely is due to differences in the screening by counter ions. It can be shown that the attractive forces generated by an oscillating dipole can increase the concentration of Rh-dUTP by a factor 2. Likewise a substantial increase of concentration can be obtained for Rh-labeled DNA molecules when linear voltage gradients are applied. The importance for diagnostic analysis at the single molecule level is discussed.

DNA↗

(13)C-(1)H NMR relaxation and fluorescence anisotropy decay study of tyrosine dynamics in motilin.

Tyrosine ring dynamics of the gastrointestinal hormone motilin was studied using two independent physical methods: fluorescence polarization anisotropy decay and NMR relaxation. Motilin, a 22-residue peptide, was selectively (13)C labeled in the ring epsilon-carbons of the single tyrosine residue. To eliminate effects of differences in peptide concentration, the same motilin sample was used in both experiments. NMR relaxation rates of the tyrosine ring C(epsilon)-H(epsilon) vectors, measured at four magnetic field strengths (9.4, 11.7, 14.1, and 18.8 Tesla) were used to map the spectral density function. When the data were analyzed using dynamic models with the same number of components, the dynamic parameters from NMR and fluorescence are in excellent agreement. However, the estimated rotational correlation times depend on the choice of dynamic model. The correlation times estimated from the two-component model-free approach and the three-component models were significantly different (1.7 ns and 2.2 ns, respectively). Various earlier studies of protein dynamics by NMR and fluorescence were compared. The rotational correlation times estimated by NMR for samples with high protein concentration were on average 18% longer for folded monomeric proteins than the corresponding times estimated by fluorescence polarization anisotropy decay, after correction for differences in viscosity due to temperature and D(2)O/H(2)O ratio.

Animals↗

Parallel single molecule detection with a fully integrated single-photon 2x2 CMOS detector array.

We present parallel single molecule detection (SMD) and fluorescence correlation spectroscopy (FCS) experiments with a fully integrated complementary metal oxide semiconductor (CMOS) single-photon 2x2 detector array. Multifocal excitation is achieved with a diffractive optical element (DOE). Special emphasis is placed on parallelization of the total system. The performance of the novel single-photon CMOS detector is investigated and compared to a state-of-the-art single-photon detecting module [having an actively quenched avalanche photodiode (APD)] by measurements on free diffusing molecules at different concentrations. Despite the order of magnitude lower detection efficiency of the CMOS detector compared to the state-of-the-art single-photon detecting module, we achieve single molecule sensitivity and reliably determine molecule concentrations. In addition, the CMOS detector performance for the determination of the fraction of slowly diffusing molecules in a primer solution (two-component analysis) is demonstrated. The potential of this new technique for high-throughput confocal-detection-based systems is discussed.

Biopolymers↗

Parallel dual-color fluorescence cross-correlation spectroscopy using diffractive optical elements.

Dual-color cross-correlation spectroscopy allows the detection and quantification of labeled biomolecules at ultra-low concentrations, whereby the sensitivity of the assay correlates with the measurement time. We now describe a parallel multifocal dual-color spectroscopic configuration employing multiple avalanche photodiodes and hardware correlators. Cross-correlation curves are obtained from several dual-color excitation foci simultaneously. Multifocal dual-color excitation is achieved by splitting each of two laser beams (488 and 633 nm) into four sub-beams with the help of two 2x2 fan-out diffractive optical elements (DOEs), and subsequent superposition of the two sets of four foci. The fluorescence emission from double-labeled biomolecules is detected by two 2x2 fiber arrays.

Equipment Design↗