PubMed Health⌕ Search

Biomedical subjects

Rudolf Stollberger

Publications and source records attributed to Rudolf Stollberger.

3 recordsLinked to original sources

Automated unwrapping of MR phase images applied to BOLD MR-venography at 3 Tesla.

PURPOSE: To improve the diagnostic value of BOLD MR-Venography by removing artifacts related to phase wrapping, particularly in regions of large background susceptibilities at high magnetic field strengths. MATERIALS AND METHODS: High resolution, T(2)(*)-weighted, single echo images were acquired on a 3 T system (Medspec 30/80 Avance, Bruker Medical, Ettlingen, Germany) with a three-dimensional, first order velocity compensated gradient echo sequence using a quadrature transmit/receive birdcage head coil. Data of nine healthy subjects and 19 patients were evaluated (age range: 27 to 76 years). To achieve improved MR-venograms, a fully automated region-growing phase unwrapping algorithm and subsequent high pass filtering were applied to phase images prior to the computation of minimum intensity projections. RESULTS: Considerably improved visualization of venous structures in regions of large background susceptibility-induced field inhomogeneities is demonstrated in healthy subjects and patients with brain tumors. CONCLUSION: BOLD MR venograms are improved compared to previous post-processing algorithms. It is now feasible to obtain high-resolution images also in inhomogeneous regions, which increases the clinical potential of BOLD MR-Venography.

Adult↗

Diffusion-weighted imaging of the spinal cord: interleaved echo-planar imaging is superior to fast spin-echo.

PURPOSE: To compare and evaluate two novel diffusion-weighted sequences, based either on fast spin-echo (FSE) or interleaved echo-planar imaging (EPI) methods, as potential tools for investing spinal cord abnormalities. MATERIALS AND METHODS: Following recent improvements, both interleaved EPI (IEPI) and FSE techniques could be alternative approaches for rapid diffusion-weighted imaging (DWI). Therefore, a navigated diffusion-weighted multishot FSE sequence and a fat-suppressed navigated diffusion-weighted IEPI sequence with local shimming capabilities were tested. Both methods were compared in a consecutive series of five healthy volunteers and five patients with suspected intramedullary lesions. The sequences were graded qualitatively as either superior, inferior, or equal in quality, and also quantitatively by measuring the amount of ghosting artifacts in the background. Quantitative measurements of the diffusion coefficients within the spine were included. RESULTS: The overall image quality of IEPI was superior to FSE. Two out of five FSE scans were rated with poor image quality, whereas all IEPI scans were of sufficient quality. The ghosting levels ranged from approximately 3.3% to 6.2% for IEPI and from approximately 7.5% to 18.9% for FSE. Diffusion coefficients measured in healthy volunteers were similar for both IEPI and FSE, but showed higher fluctuations with the FSE technique. CONCLUSION: Despite potential advantages of FSE, the IEPI technique is preferable for DWI applications in the spinal cord.

Diffusion↗

Diffusion tensor imaging using single-shot SENSE-EPI.

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.

Brain↗