PubMed Health⌕ Search

Biomedical subjects

Ruediger Grewer

Publications and source records attributed to Ruediger Grewer.

2 recordsLinked to original sources

Modality-integrated magnetic catheter tracking for x-ray vascular interventions.

A novel setup for the integration of a magnetic tracking system (MTS) into a catheter laboratory environment by attaching the field generator of the MTS to the C-arm of the x-ray system was investigated. The metal interference of the x-ray system with the MTS then becomes static and can be calibrated. The registration of a tracked catheter to 2D live x-ray images with high and well-defined accuracy is thus possible for arbitrary C-arm positions. Interference with imaging by blocking the field of view is avoided. Real-time registration methods to maintain the registration of the catheter also to static 2D or 3D images (roadmaps), regardless of the C-arm rotation during catheter tracking, were investigated. Residual registration errors of the tracked catheter with respect to the static roadmaps (2D and 3D) were reduced by using the vessel geometry and shape information. The algorithms potentially allow for motion correction (e.g. due to respiration). Using the shape-based correction algorithms the average registration accuracies to static roadmaps for different C-arm angulations and catheter positions were determined to be 3.3-4.2 mm. The magnetic registration of the C-arm was furthermore allowed to compute the imaging geometry (position of the C-arm) and to produce virtual angiographic preview images before contrast injection and x-ray dose application. Thus, optimal projection geometries and collimator settings for the target region can be chosen in an 'off line' fashion. The proposed MTS-supported navigation setup on both 3D (static) and 2D (live and static) roadmaps merges the high resolution and real-time feedback of 2D x-ray images with the navigation support from 3D static images.

Algorithms↗

Motion compensation for interventional navigation on 3D static roadmaps based on an affine model and gating.

Current cardiac interventions are performed under 2D fluoroscopy, which comes along with well-known burdens to patients and physicians, such as x-ray exposure and the use of contrast agent. Furthermore, the navigation on complex structures such as the coronaries is complicated by the use of 2D images in which the catheter position is only visible while the contrast agent is introduced. In this work, a new method is presented, which circumvents these drawbacks and enables the cardiac interventional navigation on motion-compensated 3D static roadmaps. For this, the catheter position is continuously reconstructed within a previously acquired 3D roadmap of the coronaries. The motion compensation makes use of an affine motion model for compensating the respiratory motion and compensates the motion due to cardiac contraction by gating the catheter position. In this process, only those positions which have been acquired during the rest phase of the heart are used for the reconstruction. The method necessitates the measurement of the catheter position, which is done by using a magnetic tracking system. Nevertheless, other techniques, such as image-based catheter tracking, can be applied. This motion compensation has been tested on a dynamic heart phantom. The evaluation shows that the algorithm can reconstruct the catheter position on the 3D static roadmap precisely with a residual motion of 1.0 mm and less.

Algorithms↗