PubMed Health⌕ Search

Biomedical subjects

Ruey-Feng Chang

Publications and source records attributed to Ruey-Feng Chang.

At least 19 recordsLinked to original sources

Breast Cancer Recurrence Status Assessment in 5 Years Using Multimodal Integrated Learning: A Feasibility Study.

Despite advances in breast cancer detection and treatment, recurrence after curative therapy continues to impact long-term survival and quality of life. Therefore, early identification of high-risk patients is crucial to guide personalized treatment and follow-up strategies. Although genomic assays provide valuable prognostic insights, their high cost and limited accessibility hinder widespread adoption in clinical practice. Recent machine learning or deep learning approaches leveraging clinical, imaging, or multimodal data have shown promise but do not reflect real-world clinical scenarios. This study proposes a deep learning-based multimodal framework for predicting 5-year breast cancer recurrence using routinely collected clinical data. The framework consists of three main components. First, we adopted automated tumor segmentation with MedSAM to extract the tumor region from ultrasound images. The radiomics features are extracted from those tumor regions. Second, report features are extracted using a Med-Contrastive Pre-trained Transformers (MedCPT)-based approach incorporating predefined, clinically informed queries. Third, a multimodal integration model jointly processes image, radiomics, clinical features, and report features through modality-specific branches. The image branch employs the Ultrasound Foundation Model (USFM) as the backbone, while structured tabular data is processed using the FT-Transformer architecture. The features of all branches are fused using a mixture-of-experts (MoE)-based classifier, and the entire model is trained using a progressive fusion training strategy. Experimental results confirm the feasibility of using ultrasound images with tumor mask integration for recurrence prediction and demonstrate the additive value of integrating multiple data modalities through the proposed multimodal integration model. The final model for recurrence prediction achieved an AUC of 0.7540, accuracy of 74.61%, sensitivity of 70.41%, and specificity of 76.44%. This feasibility study's findings underscore the potential of the proposed multimodal deep learning framework to provide accessible, accurate, and generalizable recurrence risk prediction using routinely available clinical data, potentially supporting more informed treatment decisions and personalized post-treatment monitoring in real-world clinical practice.

Breast cancer recurrence↗

2-D ultrasound strain images for breast cancer diagnosis using nonrigid subregion registration.

Tissue elasticity of a lesion is a useful criterion for the diagnosis of breast ultrasound (US). Elastograms are created by comparing ultrasonic radio-frequency waveforms before and after a light-tissue compression. In this study, we evaluate the accuracy of continuous US strain image in the classification of benign from malignant breast tumors. A series of B-mode US images is applied and each case involves 60 continuous images obtained by using the steady artificial pressure of the US probe. In general, after compression by the US probe, a soft benign tumor will become flatter than a stiffened malignant tumor. We proposed a computer-aided diagnostic (CAD) system by utilizing the nonrigid image registration modality on the analysis of tumor deformation. Furthermore, we used some image preprocessing methods, which included the level set segmentation, to improve the performance. One-hundred pathology-proven cases, including 60 benign breast tumors and 40 malignant tumors, were used in the experiments to test the classification accuracy of the proposed method. Four characteristic values--normalized slope of metric value (NSM), normalized area difference (NAD), normalized standard deviation (NSD) and normalized center translation (NCT)--were computed for all cases. By using the support vector machine, the accuracy, sensitivity, specificity and positive and negative predictive values of the classification of continuous US strain images were satisfactory. The A(z) value of the support vector machine based on the four characteristic values used for the classification of solid breast tumors was 0.9358.

Adult↗

Computer algorithm for analysing breast tumor angiogenesis using 3-D power Doppler ultrasound.

Angiogenesis provides blood supply for tumor expansion and also increases the opportunity for tumor cells to enter the blood or lymph circulation. Several proangiogenic factors as well as the contribution of the microenvironment to tumor-induced angiogenesis have been identified. Among these, vascular endothelial growth factor (VEGF) and the angiopoietin (Ang) family play a predominant role involved in the growth for endothelial cells. Tumor vessels are structurally and functionally abnormal because of an imbalance of these angiogenic regulators. In contrast to normal vessels, tumor vasculature is highly disorganized, tortuous and dilated, with uneven diameter and excessive branching. In other words, the morphologic features are likely to carry additional clues that, when used in conjunction with more established parameters, can improve the present diagnostic approaches. In our study, we present a new method that helps to capture the morphologic features from three-dimensional (3-D) power Doppler ultrasound (PDUS) images. After narrowing down the vessels into their skeletons using a 3-D thinning algorithm, we extracted seven features including vessel-to-volume ratio, number of vascular trees, number of bifurcation, mean of radius and three tortuosity measures, from the skeleton and applied a neural network to classify the tumors by using these features. In investigations into 221 solid breast tumors, including 110 benign and 111 malignant cases, the p values using the Student's t-test for all features were less than 0.05, indicating that the proposed features were deemed statistically significant. The A(Z) values for these seven features were 0.84, 0.87, 0.84, 0.75, 0.77, 0.79 and 0.69, respectively. The accuracy, sensitivity, specificity, and positive and negative predictive values were 80.09% (177 of 221), 80.18% (89 of 111), 80% (88 of 110), 80.18% (89 of 111) and 80% (88 of 110), respectively, with an A(Z) value of 0.89. The preliminary results show that the proposed method is feasible and has a good agreement with the diagnosis of the pathologists.

Adult↗

Automatic ultrasound segmentation and morphology based diagnosis of solid breast tumors.

Ultrasound (US) is a useful diagnostic tool to distinguish benign from malignant masses of the breast. It is a very convenient and safe diagnostic method. However, there is a considerable overlap benignancy and malignancy in ultrasonic images and interpretation is subjective. A high performance breast tumors computer-aided diagnosis (CAD) system can provide an accurate and reliable diagnostic second opinion for physicians to distinguish benign breast lesions from malignant ones. The potential of sonographic texture analysis to improve breast tumor classifications has been demonstrated. However, the texture analysis is system-dependent. The disadvantages of these systems which use texture analysis to classify tumors are they usually perform well only in one specific ultrasound system. While Morphological based US diagnosis of breast tumor will take the advantage of nearly independent to either the setting of US system and different US machines. In this study, the tumors are segmented using the newly developed level set method at first and then six morphologic features are used to distinguish the benign and malignant cases. The support vector machine (SVM) is used to classify the tumors. There are 210 ultrasonic images of pathologically proven benign breast tumors from 120 patients and carcinomas from 90 patients in the ultrasonic image database. The database contains only one image from each patient. The ultrasonic images are captured at the largest diameter of the tumor. The images are collected consecutively from August 1, 1999 to May 31, 2000; the patients' ages ranged from 18 to 64 years. Sonography is performed using an ATL HDI 3000 system with a L10-5 small part transducer. In the experiment, the accuracy of SVM with shape information for classifying malignancies is 90.95% (191/210), the sensitivity is 88.89% (80/90), the specificity is 92.5% (111/120), the positive predictive value is 89.89% (80/89), and the negative predictive value is 91.74% (111/121).

Adolescent↗

3-D ultrasound texture classification using run difference matrix.

Ultrasonography is one of the most useful diagnostic tools for human soft tissue and it is in routine use in nearly all hospitals and many physicians' offices and clinics. However, the diagnosis mostly depends upon the personal experiences of the physicians. Moreover, the surface features and internal architecture of a tumor are not easy to be demonstrated simultaneously using the conventional two-dimensional (2-D) ultrasound. Recently, three-dimensional (3-D) ultrasound has been developed and allows the physician to view the 3-D anatomy. 3-D breast US can provide transverse, longitudinal planes as well as in addition simultaneously the coronal plane. This additional information has been proved to be helpful for clinical applications. In this paper, a new approach of texture classification of 3-D ultrasound breast diagnosis using run difference matrix with neural networks is developed. The test 3-D US image database includes 54 malignant and 161 benign tumors. In the experiments, the area index A(z) under the ROC curve of the proposal 3-D RDM method can achieve 0.9680. The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of the proposed 3-D RDM method is 91.9%(148/161), 88.9%(48/54), 93.5%(100/107), 87.3%(48/55), and 94.3%(100/105), respectively.

Area Under Curve↗

Solid breast masses: classification with computer-aided analysis of continuous US images obtained with probe compression.

PURPOSE: To prospectively evaluate the accuracy of continuous ultrasonographic (US) images obtained during probe compression and computer-aided analysis for classification of biopsy-proved (reference standard) benign and malignant breast tumors. MATERIALS AND METHODS: This study was approved by the local ethics committee, and informed consent was obtained from all included patients. Serial US images of 100 solid breast masses (60 benign and 40 malignant tumors) were obtained with US probe compression in 86 patients (mean age, 45 years; range, 20-67 years). After segmentation of tumor contours with the level-set method, three features of strain on tissue from probe compression--contour difference, shift distance, area difference--and one feature of shape--solidity-were computed. A maximum margin classifier was used to classify the tumors by using these four features. The Student t test and receiver operating characteristic curve analysis were used for statistical analysis. RESULTS: The mean values of contour difference, shift distance, area difference, and solidity were 3.52% +/- 2.12 (standard deviation), 2.62 +/- 1.31, 1.08% +/- 0.85, and 1.70 +/- 1.85 in malignant tumors and 9.72% +/- 4.54, 5.04 +/- 2.79, 3.17% +/- 2.86, and 0.53 +/- 0.63 in benign tumors, respectively. Differences with P < .001 were statistically significant for all four features. Area under the receiver operating characteristic curve (A(Z)) values for contour difference, shift distance, area difference, and solidity were 0.88, 0.85, 0.86, and 0.79, respectively. The A(Z) value of three features of strain was significantly higher than that of the feature of shape (P < .01). The accuracy, sensitivity, specificity, and positive and negative predictive values of US classifications that were based on values for these four features were 87.0% (87 of 100), 85% (34 of 40), 88% (53 of 60), 83% (34 of 41), and 90% (53 of 59), respectively, with an A(Z) value of 0.91. CONCLUSION: Continuous US images obtained with probe compression and computer-aided analysis can aid in classification of benign and malignant breast tumors.

Adult↗

Three-dimensional ultrasound in margin evaluation for breast tumor excision using Mammotome.

Sonographic evidence of tumor removal by Mammotome excision does not confirm histological clearance. The operator finds it hard to determine if a malignant tumor has been fully removed, leaving a safe margin in the direction of each border; that is, the spatial orientation during tumor retrieval is not well-established by naked eye under sonographic guidance. We propose a computational imaging process to extract reasonable tumor contour in pre- and postoperative data sets for sonographic guidance so that Mammotome excision can help the operator to evaluate the surgical outcome. There were five tumors in the study, including three benign and two malignant. The lesion of interest was delineated after 2-D examination was completed, then it was analyzed with 3-D breast ultrasound (US). To give a reference point for correlations between pre- and postoperative images, we used a marker tape pasted on the skin within the transducer scanning area and then the preoperative 3-D US images were obtained. Subsequently, 2-D breast US was applied during Mammotome operation. After the Mammotome procedures were finished, the postoperative 3-D US images were obtained; thus, we gained two different data sets of 3-D US images that were used for later analysis for evaluating the extension of postoperative margin status. From the results, the safe margin was not satisfactory in all directions, because the minimum differences measured by the proposed algorithm were not large enough in all five cases, and this was proved from two malignant mastectomy specimens. The experimental results representing this inadequate Mammotome excision can be visualized through the computer aid. The comparison of tumor contour and excision margin may possibly be used for small malignant tumors in the future to improve the breast-conserving surgery.

Breast Neoplasms↗

Characterization of spiculation on ultrasound lesions.

Spiculation is a stellate distortion caused by the intrusion of breast cancer into surrounding tissue. Its existence is an important clue to characterizing malignant tumors. Many successful mammographic methods have been proposed to detect tumors with spiculation. Traditional two-dimensional (2-D) ultrasound cannot easily find spiculations because spiculations normally appear parallel to the surface of the skin. Recently, three-dimensional (3-D) ultrasound has been gradually used in clinical applications and it has been proven to be useful in determining the architectural distortion or spiculation that surrounds a breast tumor. This paper aims to identify spiculation from 3-D ultrasonic volume data of a tumor found by a physician. In the proposed method, each coronal slice of volume data is successively extracted and then analyzed as a 2-D ultrasound image by the proposed spiculation detection method. First, in each horizontal slice, the modified rotating structuring element (ROSE) operation is used to find the central region in which spiculation lines converge. Second, the stick algorithm is used to estimate the direction of the edge of each pixel around the central region. A pixel whose edge points toward the central region is marked as a potential spiculation. Finally, the marked pixels are collected around the central region and their distribution is analyzed to determine whether spiculation is present. The 3-D test datasets were obtained using the Voluson 530 or 730, Kretztechnik, Austria. First, the proposed method was tested on 104 2-D typical coronal images (selected by an experienced physician) extracted from 52 3-D ultrasonic datasets. Finally, 225 3-D pathologically proven datasets were tested to evaluate the performance. Spiculations are more easily observed in the coronal view than in the other two views. That is, the 3-D ultrasound is a powerful tool for identifying spiculations. Furthermore, 16% (19/120) of benign cases and 90% (94/105) of malignant cases are detected as spiculations.

Algorithms↗

Computer-aided diagnosis for 3-dimensional breast ultrasonography.

HYPOTHESIS: Using 3-dimensional (3-D) over 2-dimensional (2-D) ultrasonographic (US) images of the breast represents a potentially significant advantage for computer-aided diagnosis (CAD). BACKGROUND: Although conventional 2-D US images of the breast are increasingly used in surgical clinical practice, 3-D US imaging of the breast, a newly introduced technique, can offer more information than 2-D US images do. DESIGN: This study deals with a CAD method for use with the proposed 3-D US images of the breast and compares its performance with conventional 2-D US versions. METHODS: The test databases included 3-D US images of 107 benign and 54 malignant breast tumors for a total of 161 US images. All solid nodules at US belong to categories above C3 (ie, probably benign). The 3-D US imaging was performed using a scanner (Voluson 530; Kretz Technik, Zipf, Austria). New 3-D autocorrelation coefficients extended from the traditional 2-D autocorrelations were developed to extract the texture characteristics of the 3-D US images. The extracted texture features of the 3-D US images were used to classify the tumor as benign or malignant using the neural network. RESULTS: At the receiver operating characteristic analysis, 3-D and 2-D autocorrelation calculating schemes yielded Az values (ie, area under the receiver operating characteristic curve) of 0.97 and 0.85 in distinguishing between benign and malignant lesions, respectively. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value are statistically significantly improved using 3-D instead of 2-D US images for CAD. CONCLUSIONS: The proposed system (for 3-D and 2-D CAD) is expected to be a useful computer-aided diagnostic tool for classifying benign and malignant tumors on ultrasonograms and can provide a second reading to help reduce misdiagnosis. Findings from this study suggest that using 3-D over 2-D US images for CAD represents a potentially significant advantage.

Breast Neoplasms↗

Improvement in breast tumor discrimination by support vector machines and speckle-emphasis texture analysis.

Recent statistics show that breast cancer is a major cause of death among women in developed countries. Hence, finding an accurate and effective diagnostic method is very important. In this paper, we propose a high precision computer-aided diagnosis (CAD) system for sonography. We utilize a support vector machine (SVM) to classify breast tumors according to their texture information surrounding speckle pixels. We test our system with 250 pathologically-proven breast tumors including 140 benign and 110 malignant ones. Also we compare the diagnostic performances of three texture features, i.e., speckle-emphasis texture feature, nonspeckle-emphasis texture feature and conventional all pixels texture feature, applied to breast sonography using SVM. In our experiment, the accuracy of SVM with speckle information for classifying malignancies is 93.2% (233/250), the sensitivity is 95.45% (105/110), the specificity is 91.43% (128/140), the positive predictive value is 89.74% (105/117) and the negative predictive value is 96.24% (128/133). Based on the experimental results, speckle phenomenon is a useful tool to be used in computer-aided diagnosis; its performance is better than those of the other two features. Speckle phenomenon, which is considered as noise in sonography, can intrude into judgments of a physician using naked eyes but it is another story for application in a computer-aided diagnosis algorithm.

Algorithms↗

3-D US frame positioning using speckle decorrelation and image registration.

In this paper, a new positioning system is proposed for the 3-D ultrasound (US). This system combines the image registration technique and speckle decorrelation algorithm to accurately position sequential ultrasonic images without any additional positioning hardware. The speckle decorrelation algorithm estimates the relative distance of two neighboring frames and the image registration technique gets the range of the whole 3-D ultrasonic data set and makes slight modification on each frame's position. The image registration technique is based on the reference image, which is perpendicular to the 3-D ultrasonic data set. This reference image intersects each frame of the 3-D ultrasonic data set in a line. For each frame, the intersectional line is first found and then the location in the reference image can be used to estimate the position of this frame. This system uses the data set of consecutive 2-D freehand-scanned US B-mode images to construct the 3-D US volume data, and it can be integrated into the 3-D US volume rendering system.

Algorithms↗

Breast cancer diagnosis using three-dimensional ultrasound and pixel relation analysis.

Because ultrasound (US) imaging offers benefits compared with other medical imaging techniques, it is used routinely in nearly all hospitals and many clinics. However, the surface features and internal structure of a tumor are not easily demonstrated simultaneously using the traditional 2-D US. The newly developed three-dimensional (3-D) US can capture the morphology of a breast tumor and overcome the limitations of the traditional 2-D US. This study deals with pixel relation analysis techniques for use with 3-D breast US images and compares its performance to 2-D versions of the images. The 3-D US imaging was performed using a Voluson 530 scanner. The rectangular subimages of the volume-of-interest (VOI) were manually selected and the selected VOIs were outlined to include the entire extent of the tumor margin. The databases in this study included 54 malignant and 161 benign tumors. All solid nodules at US belong over C3 (probably benign) according to ACR BI-RADS category. All or some selected 2-D slices were used separately to calculate the diagnosis features for a 3-D US data set. We have proposed and compared several different methods to extract the characteristics of these consecutive 2-D images. As shown in our experiments, the diagnostic results were better than those of the conventional 2-D US. In the experiments, the area index Az under ROC curve of the proposed 3-D US method can achieve 0.9700 +/- 0.0118, but Az of the 2-D US is only 0.8461 +/- 0.0315. The p value of these two Az differences using z test is smaller than 0.01. Furthermore, we can find that the features from only several slices are enough to provide good diagnostic results if the adopted features are modified from the 2-D features.

Breast Neoplasms↗

3-D breast ultrasound segmentation using active contour model.

In this study, we made use of the discrete active contour model to overcome the natural properties of ultrasound (US) images, speckle, noise and tissue-related textures, to segment the breast tumors precisely. Determination of the real tumor boundary with the snake-deformation process requires an initial contour estimate. However, the manual way to sketch an initial contour is very time-consuming. Thus, we propose an automatic initial contour-finding method that not only maintains the tumor shape, but also is close to the tumor boundary and inside the tumor. During the deformation process, to prevent the snake trapping into the false position caused by tissue-related texture or speckle, we added the edge information as an image feature to define the external force. In addition, because the 3-D volume of a tumor is essentially constructed by a sequence of 2-D images, our method for finding boundaries of a tumor can be extended to 3-D cases. By precisely counting the volume of the 3-D images, we can get the volume of tumor. Finally, we will show that the proposed techniques have rather good performance and lead to a satisfactory result in comparison with the estimated volume and physician's estimate.

Breast Neoplasms↗

Support vector machines for diagnosis of breast tumors on US images.

RATIONALE AND OBJECTIVES: Breast cancer has become the leading cause of cancer deaths among women in developed countries. To decrease the related mortality, disease must be treated as early as possible, but it is hard to detect and diagnose tumors at an early stage. A well-designed computer-aided diagnostic system can help physicians avoid misdiagnosis and avoid unnecessary biopsy without missing cancers. In this study, the authors tested one such system to determine its effectiveness. MATERIALS AND METHODS: Many computer-aided diagnostic systems for ultrasonography are based on the neural network model and classify breast tumors according to texture features. The authors tested a refinement of this model, an advanced support vector machine (SVM), in 250 cases of pathologically proved breast tumors (140 benign and 110 malignant), and compared its performance with that of a multilayer propagation neural network. RESULTS: The accuracy of the SVM for classifying malignancies was 85.6% (214 of 250); the sensitivity, 95.45% (105 of 110); the specificity, 77.86% (109 of 140); the positive predictive value, 77.21% (105 of 136); and the negative predictive value, 95.61% (109 of 114). CONCLUSION: The SVM proved helpful in the imaging diagnosis of breast cancer. The classification ability of the SVM is nearly equal to that of the neural network model, and the SVM has a much shorter training time (1 vs 189 seconds). Given the increasing size and complexity of data sets, the SVM is therefore preferable for computer-aided diagnosis.

Breast Neoplasms↗

3-D snake for US in margin evaluation for malignant breast tumor excision using Mammotome.

The goal of this paper is to use the three-dimensional (3-D) snake technique in 3-D ultrasound to obtain the tumor contour for the pre- and the post-operative malignant breast excision by the vacuum assisted biopsy instrument Mammotome. This technique of assessing the margin of two can help the physician to evaluate the effect of the surgery. By using the anisotropic diffusion filter, the noise and speckles can be reduced. Then the stick detection is adopted for enhancing the edge. Finally, the gradient vector flow (GVF) snake is used to obtain the tumor contour. These techniques are extended to the 3-D techniques to increase the accuracy and robust of segmentation results. We hope that this study can help physicians to improve the minimal invasive operation for a breast tumor.

Anatomy, Cross-Sectional↗

Use of the bootstrap technique with small training sets for computer-aided diagnosis in breast ultrasound.

The purpose of this study was to test the efficacy of using small training sets in computer-aided diagnostic systems (CAD) and to increase the capabilities of ultrasound (US) technology in the differential diagnosis of solid breast tumors. A total of 263 sonographic images of solid breast nodules, including 129 malignancies and 134 benign nodules, were evaluated by using a bootstrap technique with 10 original training samples. Texture parameters of a region-of-interest (ROI) were resampled with a bootstrap technique and a decision-tree model was used to classify the tumor as benign or malignant. The accuracy was 87.07% (229 of 263 tumors), the sensitivity was 95.35% (123 of 129), the specificity was 79.10% (106 of 134), the positive predictive value was 81.46% (123 of 151), and the negative predictive value was 94.64% (106 of 112). This analysis method provides a second opinion for physicians with high accuracy. The new method shows a potential to be useful in future application of CAD, especially when a large database cannot be obtained for training or a newly developed ultrasonic system has smaller sets of samples.

Adolescent↗

Retrieval technique for the diagnosis of solid breast tumors on sonogram.

We evaluated a series of pathologically proven breast tumors using an image-retrieval technique for classifying benign and malignant lesions. A total of 263 breast tumors (129 malignant and 134 benign) were retrospectively evaluated. The physician located regions-of-interest (ROI) of ultrasonic images and texture parameters (contrast, covariance and dissimilarity) were used in the process of the content-based image-retrieval technique. The accuracy of using the retrieval technique for classifying malignancies was 92.55% (236 of 255), the sensitivity was 94.44% (119 of 126), the specificity was 90.70% (117 of 129), the positive predictive value was 90.84% (119 of 131), and negative predictive value was 94.35% (117 of 124) for the proposed computer-aided diagnostic system. This computer-aided diagnosis system can provide a useful tool and its high negative predictive value could potentially help avert benign biopsies. It is unnecessary to perform any training procedures. This computer-aided diagnosis system can provide a second opinion for a sonographic interpreter; the main advantage in this proposed system is that we do not need any training. Historical cases can be directly added into the database and training of the diagnosis system again is not needed. With the growth of the database, more and more information can be collected and used as reference cases while performing diagnoses. This increases the flexibility of our diagnostic system.

Adolescent↗

Diagnosis of breast tumors with sonographic texture analysis using wavelet transform and neural networks.

To increase the ability of ultrasonographic technology for the differential diagnosis of solid breast tumors, we describe a novel computer-aided diagnosis (CADx) system using neural networks for classification of breast tumors. Tumor regions and surrounding tissues are segmented from the physician-located region-of-interest (ROI) images by applying our proposed segmentation algorithm. Cooperating with the segmentation algorithm, three feasible features, including variance contrast, autocorrelation contrast and distribution distortion of wavelet coefficients, were extracted from the ROI images for further classification. A multilayered perceptron (MLP) neural network trained using error back-propagation algorithm with momentum was then used for the differential diagnosis of breast tumors on sonograms. In the experiment, 242 cases (including benign breast tumors from 161 patients and carcinomas from 82 patients) were sampled with k-fold cross-validation (k = 10) to evaluate the performance. The receiver operating characteristic (ROC) area index for the proposed CADx system is 0.9396 +/- 0.0183, the sensitivity is 98.77%, the specificity is 81.37%, the positive predictive value is 72.73% and the negative predictive value is 99.24%. Experimental results showed that our diagnosis model performed very well for breast tumor diagnosis.

Breast Diseases↗