PubMed Health⌕ Search

Biomedical subjects

Ruifeng Li

Publications and source records attributed to Ruifeng Li.

4 recordsLinked to original sources

Association of indoor nitrogen dioxide with respiratory symptoms in children: application of measurement error correction techniques to utilize data from multiple surrogates.

In 1991, Neas et al. reported that indoor nitrogen dioxide (NO(2)), a byproduct of high-temperature combustion, was significantly associated with lower respiratory symptoms among a cohort of 1,159 white children aged 7-11 years in six US cities studied from 1983 to 1988. For each 15 p.p.b. increment of NO(2), the multivariate adjusted odds ratio (OR) was 1.4 (95% confidence interval (CI)=[1.1, 1.7]). Although indoor NO(2) concentration in the ambient air was assessed only in a subset of the children, the prevalence of lower respiratory symptoms and surrogate exposure variables were available in all of the children at the time of the indoor monitoring program. This paper evaluates the effect of indoor NO(2) exposure on the annual risk of lower respiratory symptoms by applying a regression calibration method to the 2,891 children in the overall study with complete covariate and outcome data, 1,137 of whom had NO(2) directly measured and 1,754 of whom only surrogate exposure data were available. An estimate of the indoor annual NO(2) exposure effect (p.p.b.) is obtained, which is adjusted for measurement error induced by the use of surrogate NO(2) sources among the 1,754. These sources include the presence of a gas stove with or without a pilot light, the presence of a kerosene space heater, the presence of a wood stove, and the usage of a stove for heating, and residential characteristics, including fan usage for kitchen ventilation and the total number of rooms in the home. After adjusting for age, gender, city, parental history of respiratory diseases, and smoking inside the children's home (packs/day), a 15-p.p.b. increment in NO(2) exposure was found to be associated with a significant 50% increased annual risk of lower respiratory symptoms (OR=1.5, 95% CI=[1.2, 1.8]). Simulation results indicated that, under conditions similar to those observed in these data, the estimator is unbiased and has a coverage probability close to the nominal value. Using the methodology illustrated in this paper, it became possible to utilize all data available and obtain a 34% more precise estimate of the NO(2) exposure effect on lower respiratory symptoms, which was adjusted for measurement error due to using NO(2) surrogates instead of directly measured NO(2).

Air Pollution, Indoor↗

Home endotoxin exposure and wheeze in infants: correction for bias due to exposure measurement error.

Exposure to elevated levels of endotoxin in family-room dust was previously observed to be significantly associated with increased wheeze in the first year of life among a cohort of 404 children in the Boston, Massachusetts, metropolitan area. However, it is likely that family-room dust endotoxin was a surrogate for airborne endotoxin exposure. Therefore, a related substudy characterized the relationship between levels of airborne household endotoxin and the level of endotoxin present in house dust, in addition to identifying other significant predictors of airborne endotoxin in the home. We now reexamine the relationship between endotoxin exposure and wheeze under the assumption that the level of airborne endotoxin in the home is the exposure of interest and that the amount of endotoxin in household dust is a surrogate for this exposure. We applied a measurement error correction technique, using all available data to estimate the effect of endotoxin exposure in terms of airborne concentration and accounting for the measurement error induced by using house-dust endotoxin as a surrogate measure in the portion of the data in which airborne endotoxin could not be directly measured. After adjusting for confounding by lower respiratory infection status and race/ethnicity, endotoxin exposure was found to be significantly associated with a nearly 6-fold increase in prevalence of wheeze for a one interquartile range increase in airborne endotoxin (95% confidence interval, 1.2-26) among the 360 children in households with dust endotoxin levels between the 5th and 95th percentiles.

Air Pollution, Indoor↗

[Repairing large perforation of nasal septum with titanium membrane and local pedicled mucoperiosteum flap].

OBJECTIVE: To study a new treatment to repair large perforation of nasal septum with medical titanium membrane and local padicled mucoperiosteum flap. METHOD: The bottom mucoperiosteum of nasal cavity around the perforation of nasal septum were separated from the bone surface except with the margin part of perforation. Then the distal part of mucoperiosteum flap was incised and turn over to cover the perforation, free edge of the flap was sutured to secure immobilization. Finally, the Titanium membrane was cut to the right size to tuck into subperiosteal pocket around the perforation, and was sutured to the mucoperiosteal for added immobilization. RESULT: The perforations of nasal septum in 11 patients were closed satisfactorily. Perforation of nasal septum did not recur and the follow-up time ranged from half a year to 1 year. CONCLUSION: Titanium membrane is easy of application, and has good tissue tolerance. In our study, it is a good material to repair large perforation of nasal septum.

Adult↗

Comparison of multiple regression to two latent variable techniques for estimation and prediction.

In the areas of epidemiology, psychology, sociology, and other social and behavioural sciences, researchers often encounter situations where there are not only many variables contributing to a particular phenomenon, but there are also strong relationships among many of the predictor variables of interest. By using the traditional multiple regression on all the predictor variables, it is possible to have problems with interpretation and multicollinearity. As an alternative to multiple regression, we explore the use of a latent variable model that can address the relationship among the predictor variables. We consider two different methods for estimation and prediction for this model: one that uses multiple regression on factor score estimates and the other that uses structural equation modelling. The first method uses multiple regression but on a set of predicted underlying factors (i.e. factor scores), and the second method is a full-information maximum-likelihood technique that incorporates the complete covariance structure of the data. In this tutorial, we will explain the model and each estimation method, including how to carry out prediction. A data example will be used for demonstration, where respiratory disease death rates by county in Minnesota are predicted by five county-level census variables. A simulation study is performed to evaluate the efficiency of prediction using the two latent variable modelling techniques compared to multiple regression.

Censuses↗