PubMed Health⌕ Search

Biomedical subjects

Russell D Folks

Publications and source records attributed to Russell D Folks.

9 recordsLinked to original sources

Improved quantification in 123I cardiac SPECT imaging with deconvolution of septal penetration.

OBJECTIVES: (123)I is becoming an important radionuclide for cardiac imaging. Multiple, low-abundance, high-energy photons associated with (123)I imaging can cause septal penetration in the collimators and degrade quantification of the (123)I cardiac uptake. This study presents a method for the deconvolution of septal penetration (DSP) for improving quantification in (123)I cardiac single photon emission computed tomography (SPECT). METHODS: Distance-dependent point spread functions were measured for low-energy high-resolution collimators on a dual-head SPECT system. The measured point spread functions were used in two-dimensional (2-D) and three-dimensional (3-D) models of the collimator response, respectively. 2-D DSP and 3-D DSP were then developed and implemented using iterative reconstruction. A cardiac torso phantom with an internal calibration source was designed with various heart-to-calibration ratios (HCRs) simulating different levels of a patient's uptake. SPECT acquisitions of the phantom were performed using optimized acquisition and processing parameters for (123)I cardiac SPECT. HCRs were calculated using planar projection and tomographic reconstructions. The paired t-test and regression analysis were used to compare the HCRs given by different calculation methods. RESULTS: SPECT produced more accurate HCRs than planar imaging. The slopes of the regression lines for SPECT using filtered back-projection were statistically significantly higher than those for planar imaging (0.2118 +/- 0.0297 vs. 0.0819 +/- 0.0070, P = 0.0001). 2-D DSP and 3-D DSP yielded similar HCRs that were close to the true HCR. The slopes of the regression lines for 2-D DSP and 3-D DSP were 0.9203 +/- 0.0523 and 0.9101 +/- 0.0304, respectively. The DSP HCRs were significantly more accurate than those calculated without DSP (P < 0.0001). CONCLUSION: DSP significantly improves quantification in (123)I cardiac SPECT imaging. 2-D DSP with its less computational burden shows promise for implementation in clinical practice so as to allow the use of the widely available low-energy, high-resolution collimators for quantitative I cardiac SPECT imaging.

Algorithms↗

99mTc-MAG3 renography: normal values for MAG3 clearance and curve parameters, excretory parameters, and residual urine volume.

OBJECTIVE: Specific quantitative measurements have been recommended to assist in the interpretation of technetium-99m mercaptoacetyltriglycine (MAG3) renal studies. Our objective was to define the sex- and age-specific normal ranges for these recommended parameters. MATERIALS AND METHODS: Data were obtained from a retrospective analysis of 106 subjects who were evaluated for kidney donation. The MAG3 clearance was calculated using a common camera-based method. The relative uptake, prevoid/postvoid and postvoid/maximum count ratios were determined using whole-kidney regions of interest (ROIs). Time to peak, time to half-peak, 20 min/maximum and 20 min/2-3 min count ratios were determined for cortical and whole-kidney ROIs. Residual urine volume was calculated on the basis of the pre- and postvoid bladder counts and voided urine volume. RESULTS: The mean camera-based MAG3 clearance was 321 +/- 69 mL/min/1.73 m2, essentially the same as the mean plasma sample MAG3 clearance in comparable populations. The percentages of relative uptake in the right and left kidneys were 49% and 51% +/- 4%, respectively; no difference was seen between men and women. Cortical values were lower than the whole-kidney values (p < 0.001); the mean cortical 20 min/maximum count ratio was 0.19 (SD, 0.07 and 0.04 for right and left kidneys, respectively). The mean postvoid/maximum whole-kidney count ratio was < 0.1, and the mean postvoid residual bladder volume was < 30 mL. CONCLUSION: Normal limits adjusted for age and sex have been established. Applying normal ranges to quantitative MAG3 parameters may assist in the interpretation of MAG3 scintigraphy and facilitate appropriate patient management.

Adult↗

Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation.

UNLABELLED: Clinical decisions regarding diagnosis and effective treatment of coronary artery disease frequently require integration of information from various imaging modalities, which are acquired, processed, and read at different physical locations and times. We have developed methods to integrate the information in 2 cardiac imaging studies, perfusion SPECT and coronary angiography. Three-dimensional (3D) models of the coronary artery tree created from biplane angiograms were automatically aligned with 3D models of the left ventricular epicardial surface created from perfusion SPECT. Myocardial mass at risk was used as a unique measure to validate the accuracy of the unification. METHODS: Thirty patients were injected with the perfusion agent (99m)Tc-tetrosfosmin during balloon occlusion while undergoing percutaneous transluminal coronary angioplasty for single-vessel coronary artery disease. Thus, a single, severe perfusion defect was induced by a single coronary artery occlusion of known severity and placement. The accuracy of the unification was measured by computing the overlap between physiologic area at risk, determined using SPECT perfusion quantification techniques only, and anatomic area at risk, determined using coronary artery anatomy aligned with the epicardial surface of the left ventricle. RESULTS: The unification resulted in an 80% overlap of areas at risk, and an overlap of 84% of normal areas, for all coronary artery distributions. The mass at risk measured based on the unified anatomic information correlated with the physiologically based mass at risk as y = 0.92x + 10.3 g; r = 0.76, SEE = 10.4 g. CONCLUSION: A unification algorithm for automatically registering 3D models of the epicardial surface from perfusion SPECT and 3D coronary artery trees from coronary angiography has been presented and validated in 30 patient studies.

Algorithms↗

Interpretation and reporting of myocardial perfusion SPECT: a summary for technologists.

Interpretation of cardiac perfusion SPECT images, and the subsequent reporting of results to referring physicians, are sometimes taken to be outside the sphere of the nuclear medicine technologist. However, all personnel involved with nuclear medicine procedures contribute to the timeliness and usefulness of the final report. The goal of this article is to review the principles of scan interpretation and reporting, from the standpoint of what technologists need to understand about these processes. In addition, software tools to aid these processes will be discussed, including quantitative image analysis, telemedicine, computer-aided scan interpretation, databases, computer-aided reporting, and Internet-based reporting. Finally, the accuracy of the scan report will be related to the tasks normally performed by technologists, such as the acquisition and processing of images and the entry, transfer, and networking of data. After reading this article, the reader will be able to describe the principles of scan interpretation and reporting, the software tools for telemedicine and computer-aided interpretation, and the role of the technologist in this process.

Allied Health Personnel↗

Optimized acquisition and processing protocols for I-123 cardiac SPECT imaging.

BACKGROUND: Deconvolution of septal penetration (DSP) has been developed to improve quantification so as to allow the use of low-energy high-resolution collimators for iodine 123 cardiac single photon emission computed tomography (SPECT) imaging. The purpose of this study is to optimize its acquisition and processing protocols. METHODS AND RESULTS: Planar images of a 9-compartment phantom loaded with variable radioactive concentrations were acquired to derive optimal scatter compensation scaling factors for 20% and 15% photopeak energy window configurations, respectively. A cardiac phantom, loaded with high and low heart-to-calibration ratios (HCRs), respectively, was imaged with both configurations. Repeated acquisitions were done for medium-energy all-purpose collimators for comparison. Critical frequencies for Butterworth filtering were optimized by use of defect contrast and normal short-axis uniformity as selection indices. HCRs were calculated with planar projection and different reconstruction methods, respectively, and then compared with the true HCRs. SPECT produced more accurate HCRs than planar imaging. With the optimized parameters for scatter compensation and filtering, the 2 energy window configurations yielded similar results. Iterative reconstructions with DSP yielded more accurate HCRs than other reconstructions without DSP. CONCLUSION: The optimized protocols based on DSP show promise that quantification of I-123 cardiac SPECT imaging can be achieved with the widely available low-energy high-resolution collimators.

Algorithms↗

Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.

BACKGROUND: A gender-independent stress normal database and criteria for abnormality for attenuation-corrected rest-stress technetium 99m sestamibi same-day myocardial perfusion imaging were developed by evaluation of 112 patients, validated against an obese population of 95 patients from four different clinical sites, and compared with conventional gender-matched database quantification of non-attenuation-corrected studies. METHODS AND RESULTS: These 95 validation patients (63 men) were used for prospective quantitative evaluation (mean weight, 213 +/- 57 lb; mean body mass index, 32 +/- 9 kg/m(2)). This group included 21 patients (12 men) with a lower than 5% likelihood of coronary artery disease (mean weight, 226 +/- 72 lb; mean body mass index, 34 +/- 13 kg/m(2)) and 74 who underwent cardiac catheterization within 2 months (35 with normal coronaries or coronary lesions <70%). These studies were processed twice, once by use of conventional reconstruction and gender-specific database quantification and a second time by use of attenuation correction and a single gender-independent attenuation-corrected normal database. The attenuation-corrected normal database and criteria for abnormality were developed by evaluation of 48 and 78 patients, respectively. No statistically significant differences were found when comparing attenuation-corrected perfusion distributions of normal men and women, whereas significant differences were found in the same uncorrected studies. Compared with quantitative analysis of the uncorrected studies, quantitative analysis of the attenuation-corrected studies by use of a gender-independent normal database demonstrated a significant improvement in normalcy rate (90% vs 52%, P =.006) and specificity (57% vs 29%, P =.015) in this obese population at no significant loss in sensitivity (90% vs 97%, P = not significant). CONCLUSION: Attenuation-corrected studies can be quantified with a single gender-independent normal database and a single criterion for abnormality without loss of sensitivity and with significantly better specificity and normalcy rate.

Coronary Artery Disease↗

Detecting changes in serial myocardial perfusion SPECT: a simulation study.

BACKGROUND: New algorithms were evaluated for their efficacy in detecting and quantifying serial changes in myocardial perfusion from single photon emission computed tomography (SPECT). METHODS AND RESULTS: We generated 72 simulations with various left ventricular positions, sizes, count rates, and perfusion defect severities using the nonuniform rational B-splines (NURBs)-based CArdiac Torso (NCAT) phantom. Images were automatically aligned by use of both full linear and rigid transformations and quantified for perfusion by use of the CEqual program. Changes within a given perfusion defect were compared by use of a Student t test before and after registration. Registration approaches were compared by use of receiver operating characteristic analysis. Changes of 5% were not detected well in single patients with or without alignment. Changes of 10% and 15% could be detected with false-positive rates of 15% and 10%, respectively, in single studies if alignment was performed before perfusion analysis. Alignment also reduced the number of studies necessary to demonstrate a significant perfusion change (P < .05) in groups of patients by about half. CONCLUSION: Comparison of mean uptake by t values in SPECT perfusion defects can be used to detect 10% and greater differences in serial perfusion studies of single patients. Image alignment is necessary to optimize automatic detection of perfusion changes in both single patients and groups of patients.

Computer Simulation↗

Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony.

BACKGROUND: A count-based method using technetium-99m sestamibi electrocardiography-gated myocardial perfusion single photon emission computed tomography imaging has been developed to extract the left ventricular (LV) regional phase of contraction (onset of mechanical contraction [OMC]) throughout the cardiac cycle. This study was performed to develop OMC normal databases and dynamic OMC displays for assessment of cardiac mechanic dyssynchrony. METHODS AND RESULTS: LV regional phases were extracted from 90 enrolled normal subjects (45 men and 45 women) by use of the Emory Cardiac Toolbox and then submitted to statistical analysis to generate the normal databases. The LV OMC wave was dynamically propagated over the perfusion polar map by blackening either sequential phase bins or all past phases. The developed OMC normal databases consisted of peak phase (134.5 degrees +/- 14.3 degrees for men and 140.2 degrees +/- 14.9 degrees for women), phase SD (14.2 degrees +/- 5.1 degrees for men and 11.8 degrees +/- 5.2 degrees for women), and phase histogram bandwidth (38.7 degrees +/- 11.8 degrees for men and 30.6 degrees +/- 9.6 degrees for women), skewness (4.19 +/- 0.68 for men and 4.60 +/- 0.72 for women), and kurtosis (19.72 +/- 7.68 for men and 23.21 +/- 8.16 for women). Both statistical analysis and dynamic OMC displays were incorporated into a user interface as a diagnostic tool. CONCLUSION: The OMC normal databases and dynamic OMC displays should help clinicians evaluate cardiac mechanic dyssynchrony. Prospective clinical trials are needed to validate whether this tool can be used to select patients with severe heart failure symptoms who might benefit from cardiac resynchronization therapy.

Databases, Factual↗

Attenuation correction reveals gender-related differences in the normal values of transient ischemic dilation index in rest-exercise stress sestamibi myocardial perfusion imaging.

BACKGROUND: Transient ischemic dilation (TID) has been established as an important independent marker of severe and extensive coronary artery disease (CAD) in myocardial perfusion imaging (MPI). The accuracy of the TID index is dependent on a well-determined threshold (normal limits) between normal and abnormal values for each study protocol. To date, the effects of neither gender nor attenuation correction (AC) on TID normal limits have been established. Thus, the objectives of this study were to determine if AC processing changes the normal value of the TID index and if there were gender-related differences in the TID index of normal patients who had undergone rest/exercise-stress technetium-99m sestamibi MPI. METHODS AND RESULTS: Seventy-five patients (33 women, 42 men; mean age, 57.7 +/- 11.7 y and 55.9 +/- 10.0 y, respectively) with less than a 5% likelihood of CAD, who had undergone low-dose rest/high-dose exercise-stress Tc-99m sestamibi MPI, were studied. All studies were acquired using simultaneous emission/transmission scans and were corrected for attenuation, scatter, and resolution effects using the ExSPECT II method. Both the AC and non-AC studies were analyzed using the Emory Cardiac Toolbox (ECTb; Syntermed, Inc, Atlanta, Ga) quantitative software. The TID index was calculated automatically as the ratio of stress mean left ventricular volumes to rest mean left ventricular volumes by ECTb. Patients were grouped by gender and the TID indices from AC and non-AC studies were compared. Linear regressions of the TID index and body mass index were analyzed to exclude differences in body size between male and female patients as a confounding factor in gender-related differences in TID. The TID index upper normal limits were calculated as the mean value plus 2 standard deviations (SDs). AC processing did not change the TID index significantly whether the genders were combined or separated (AC TID = 0.97 +/- 0.14 vs non-AC TID = 0.98 +/- 0.12 for all patients). Female patients showed higher mean TID indices than male patients in both AC (1.01 +/- 0.15 vs 0.95 +/- 0.12) and non-AC studies (1.00 +/- 0.15 vs. 0.97 +/- 0.10), but this difference was statistically significant only in AC studies (p = .03). TID indices remained constant across the range of body mass index studied. The TID index upper normal limit was 1.31 for female and 1.18 for male patients. CONCLUSION: TID normal values for rest/exercise-stress Tc-99m sestamibi MPI are gender-dependent and not affected by AC processing. Thus, diagnosticians should take into account these gender-related differences, as compared with the traditional value generated from mostly male populations, to ensure both men and women have the same overall accuracy of using the TID index in the diagnosis and prognosis of CAD.

Adult↗