PubMed Health⌕ Search

Biomedical subjects

Rustem F Ismagilov

Publications and source records attributed to Rustem F Ismagilov.

At least 19 recordsLinked to original sources

On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system.

This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0-1.5 microg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 degrees C) and physiological temperature (37 degrees C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor's blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 degrees C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other.

Anticoagulants↗

Microfluidic cartridges preloaded with nanoliter plugs of reagents: an alternative to 96-well plates for screening.

In traditional screening with 96-well plates, microliters of substrates are consumed for each reaction. Further miniaturization is limited by the special equipment and techniques required to dispense nanoliter volumes of fluid. Plug-based microfluidics confines reagents in nanoliter plugs (droplets surrounded by fluorinated carrier fluid), and uses simple pumps to control the flow of plugs. By using cartridges pre-loaded with nanoliter plugs of reagents, only two pumps and a merging junction are needed to set up a screen. Screening with preloaded cartridges uses only nanoliters of substrate per reaction, and requires no microfabrication. The low cost and simplicity of this method has the potential of replacing 96-well and other multi-well plates, and has been applied to enzymatic assays, protein crystallization and optimization of organic reactions.

Chemical Precipitation↗

Microgram-scale testing of reaction conditions in solution using nanoliter plugs in microfluidics with detection by MALDI-MS.

This paper describes a microfluidic system to screen and optimize organic reaction conditions on a submicrogram scale. The system uses discrete droplets (plugs) as microreactors separated and transported by a continuous phase of a fluorinated carrier fluid. Previously, we demonstrated the use of a microfabricated PDMS plug-based microfluidic system to perform assays and crystallization experiments in aqueous solutions with optical detection. Here, we developed an approach that does not require microfabrication of microfluidic devices, is applicable to synthetic reactions in organic solvents, and uses detection by MALDI-MS. As a demonstration, conditions for selective deacetylation of ouabain hexaacetate were tested, and the optimum conditions for mono-, bis-, or trisdeacetylation have been identified. These conditions were validated by scale-up reactions and isolating these potentially neurotoxic products. Mono- and bisdeacetylated products are unstable intermediates in the deacetylation and were isolated for the first time. This system enables no-loss handling of submicroliter volumes containing a few micrograms of a compound of interest. It could become valuable for investigating or optimizing reactions of precious substrates (e.g., products of long synthetic sequences and natural products that can be isolated only in small quantities).

Acetylation↗

Characterization of the local temperature in space and time around a developing Drosophila embryo in a microfluidic device.

This paper characterizes a microfluidic platform that differentially controls the temperature of each half of a living Drosophila melanogaster fruitfly embryo in space and time (E. M. Lucchetta, J. H. Lee, L. A. Fu, N. H. Patel and R. F. Ismagilov, Nature, 2005, 434, 1134-1138). This platform relies on laminar flow of two streams of liquid with different temperature, and on rapid prototyping in polydimethylsiloxane (PDMS). Here, we characterized fluid flow and heat transport in this platform both experimentally and by numerical simulation, and estimated the temperature distribution around and within the embryo by numerical simulation, to identify the conditions for creating a sharper temperature difference (temperature step) over the embryo. Embryos were removed from the device and immunostained histochemically for detection of Paired protein. Biochemical processes are sensitive to small differences in environmental temperature. The microfluidic platform characterized here could prove useful in understanding dynamics of biochemical networks as they respond to changes in temperature.

Algorithms↗

Using microfluidics to observe the effect of mixing on nucleation of protein crystals.

This paper analyzes the effect of mixing on nucleation of protein crystals. The mixing of protein and precipitant was controlled by changing the flow rate in a plug-based microfluidic system. The nucleation rate inversely depended on the flow rate, and flow rate could be used to control nucleation. For example, at higher supersaturations, precipitation happened at low flow rates while large crystals grew at high flow rates. Mixing at low flow velocities in a winding channel induces nucleation more effectively than mixing in straight channels. A qualitative scaling argument that relies on a number of assumptions is presented to understand the experimental results. In addition to helping fundamental understanding, this result may be used to control nucleation, using rapid chaotic mixing to eliminate formation of precipitates at high supersaturation and using slow chaotic mixing to induce nucleation at lower supersaturation.

Crystallization↗

Combining microfluidic networks and peptide arrays for multi-enzyme assays.

This paper reports the use of microfluidic networks (muFNs) to both prepare peptide microarrays and carry out label-free enzyme assays on self-assembled monolayers (SAMs) of alkanethiolates on gold. A poly(dimethylsiloxane) (PDMS) stamp fabricated with microchannels is used to immobilize a linear array of cysteine-terminated peptides onto SAMs presenting maleimide groups. The stamp is then reapplied to the SAM in a perpendicular direction to introduce enzyme solutions so that each solution can interact with an identical linear array of immobilized peptides. The muFNs enable multiple enzyme-substrate interactions to be simultaneously evaluated at a submicroliter scale, while the use of SAMs enables the use of MALDI mass spectrometry (MS) to analyze the enzyme activities. This paper demonstrates applications of this system for assaying multiple kinases and for profiling the activities of kinases and phosphatases in human K562 cell extracts. The combination of muFN, SAMs, and MS detection provides a flexible platform for assaying enzyme activities in biological samples.

Amino Acid Sequence↗

Dynamics of Drosophila embryonic patterning network perturbed in space and time using microfluidics.

Biochemical networks are perturbed both by fluctuations in environmental conditions and genetic variation. These perturbations must be compensated for, especially when they occur during embryonic pattern formation. Complex chemical reaction networks displaying spatiotemporal dynamics have been controlled and understood by perturbing their environment in space and time. Here, we apply this approach using microfluidics to investigate the robust network in Drosophila melanogaster that compensates for variation in the Bicoid morphogen gradient. We show that the compensation system can counteract the effects of extremely unnatural environmental conditions--a temperature step--in which the anterior and posterior halves of the embryo are developing at different temperatures and thus at different rates. Embryonic patterning was normal under this condition, suggesting that a simple reciprocal gradient system is not the mechanism of compensation. Time-specific reversals of the temperature step narrowed down the critical period for compensation to between 65 and 100 min after onset of embryonic development. The microfluidic technology used here may prove useful to future studies, as it allows spatial and temporal regulation of embryonic development.

Animals↗

Controlling nonspecific protein adsorption in a plug-based microfluidic system by controlling interfacial chemistry using fluorous-phase surfactants.

Control of surface chemistry and protein adsorption is important for using microfluidic devices for biochemical analysis and high-throughput screening assays. This paper describes the control of protein adsorption at the liquid-liquid interface in a plug-based microfluidic system. The microfluidic system uses multiphase flows of immiscible fluorous and aqueous fluids to form plugs, which are aqueous droplets that are completely surrounded by fluorocarbon oil and do not come into direct contact with the hydrophobic surface of the microchannel. Protein adsorption at the aqueous-fluorous interface was controlled by using surfactants that were soluble in fluorocarbon oil but insoluble in aqueous solutions. Three perfluorinated alkane surfactants capped with different functional groups were used: a carboxylic acid, an alcohol, and a triethylene glycol group that was synthesized from commercially available materials. Using complementary methods of analysis, adsorption was characterized for several proteins (bovine serum albumin (BSA) and fibrinogen), including enzymes (ribonuclease A (RNase A) and alkaline phosphatase). These complementary methods involved characterizing adsorption in microliter-sized droplets by drop tensiometry and in nanoliter plugs by fluorescence microscopy and kinetic measurements of enzyme catalysis. The oligoethylene glycol-capped surfactant prevented protein adsorption in all cases. Adsorption of proteins to the carboxylic acid-capped surfactant in nanoliter plugs could be described by using the Langmuir model and tensiometry results for microliter drops. The microfluidic system was fabricated using rapid prototyping in poly(dimethylsiloxane) (PDMS). Black PDMS microfluidic devices, fabricated by curing a suspension of charcoal in PDMS, were used to measure the changes in fluorescence intensity more sensitively. This system will be useful for microfluidic bioassays, enzymatic kinetics, and protein crystallization, because it does not require surface modification during fabrication to control surface chemistry and protein adsorption.

Adsorption↗

Using nanoliter plugs in microfluidics to facilitate and understand protein crystallization.

Protein crystallization is important for determining protein structures by X-ray diffraction. Nanoliter-sized plugs--aqueous droplets surrounded by a fluorinated carrier fluid--have been applied to the screening of protein crystallization conditions. Preformed arrays of plugs in capillary cartridges enable sparse matrix screening. Crystals grown in plugs inside a microcapillary may be analyzed by in situ X-ray diffraction. Screening using plugs, which are easily formed in PDMS microfluidic channels, is simple and economical, and minimizes consumption of the protein. This approach also has the potential to improve our understanding of the fundamentals of protein crystallization, such as the effect of mixing on the nucleation of crystals.

Animals↗

Formation of droplets of alternating composition in microfluidic channels and applications to indexing of concentrations in droplet-based assays.

For screening the conditions for a reaction by using droplets (or plugs) as microreactors, the composition of the droplets must be indexed. Indexing here refers to measuring the concentration of a solute by addition of a marker, either internal or external. Indexing may be performed by forming droplet pairs, where in each pair the first droplet is used to conduct the reaction, and the second droplet is used to index the composition of the first droplet. This paper characterizes a method for creating droplet pairs by generating alternating droplets, of two sets of aqueous solutions in a flow of immiscible carrier fluid within PDMS and glass microfluidic channels. The paper also demonstrates that the technique can be used to index the composition of the droplets, and this application is illustrated by screening conditions of protein crystallization. The fluid properties required to form the steady flow of the alternating droplets in a microchannel were characterized as a function of the capillary number Ca and water fraction. Four regimes were observed. At the lowest values of Ca, the droplets of the two streams coalesced; at intermediate values of Ca the alternating droplets formed reliably. At even higher values of Ca, shear forces dominated and caused formation of droplets that were smaller than the cross-sectional dimension of the channel; at the highest values of Ca, coflowing laminar streams of the two immiscible fluids formed. In addition to screening of protein crystallization conditions, understanding of the fluid flow in this system may extend this indexing approach to other chemical and biological assays performed on a microfluidic chip.

Calcium↗

Multi-step synthesis of nanoparticles performed on millisecond time scale in a microfluidic droplet-based system.

This paper reports a plug-based, microfluidic method for performing multi-step chemical reactions with millisecond time-control. It builds upon a previously reported method where aqueous reagents were injected into a flow of immiscible fluid (fluorocarbons)(H. Song et al., Angew. Chem. Int. Ed., 2003, 42, 768). The aqueous reagents formed plugs--droplets surrounded and transported by the immiscible fluid. Winding channels rapidly mixed the reagents in droplets. This paper shows that further stages of the reaction could be initiated by flowing additional reagent streams directly into the droplets of initial reaction mixture. The conditions necessary for an aqueous stream to merge with aqueous droplets were characterized. The Capillary number could be used to predict the behavior of the two-phase flow at the merging junction. By transporting solid reaction products in droplets, the products were kept from aggregating on the walls of the microchannels. To demonstrate the utility of this microfluidic method it was used to synthesize colloidal CdS and CdS/CdSe core-shell nanoparticles.

Cadmium Compounds↗

A synthetic reaction network: chemical amplification using nonequilibrium autocatalytic reactions coupled in time.

This article reports a functional chemical reaction network synthesized in a microfluidic device. This chemical network performs chemical 5000-fold amplification and shows a threshold response. It operates in a feedforward manner in two stages: the output of the first stage becomes the input of the second stage. Each stage of amplification is performed by a reaction autocatalytic in Co(2+). The microfluidic network is used to maintain the two chemical reactions away from equilibrium and control the interactions between them in time. Time control is achieved as described previously (Angew. Chem., Int. Ed. 2003, 42, 768) by compartmentalizing the reaction mixture inside plugs which are aqueous droplets carried through a microchannel by an immiscible fluorinated fluid. Autocatalytic reaction displayed sensitivity to mixing; more rapid mixing corresponded to slower reaction rates. Synthetic chemical reaction networks may help understand the function of biochemical reaction networks, the goal of systems biology. They may also find practical applications. For example, the system described here may be used to detect visually, in a simple format, picoliter volumes of nanomolar concentrations of Co(2+), an environmental pollutant.

Journal Article↗

Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets.

This paper reviews work on a microfluidic system that relies on chaotic advection to rapidly mix multiple reagents isolated in droplets (plugs). Using a combination of turns and straight sections, winding microfluidic channels create unsteady fluid flows that rapidly mix the multiple reagents contained within plugs. The scaling of mixing for a range of channel widths, flow velocities and diffusion coefficients has been investigated. Due to rapid mixing, low sample consumption and transport of reagents with no dispersion, the system is particularly appropriate for chemical kinetics and biochemical assays. The mixing occurs by chaotic advection and is rapid (sub-millisecond), allowing for an accurate description of fast reaction kinetics. In addition, mixing has been characterized and explicitly incorporated into the kinetic model.

Complex Mixtures↗

Millisecond kinetics on a microfluidic chip using nanoliters of reagents.

This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.

Biocompatible Materials↗

Screening of protein crystallization conditions on a microfluidic chip using nanoliter-size droplets.

Protein crystallization is a major bottleneck in determining tertiary protein structures from genomic sequence data. This paper describes a microfluidic system for screening hundreds of protein crystallization conditions using less than 4 nL of protein solution for each crystallization droplet. The droplets are formed by mixing protein, precipitant, and additive stock solutions in variable ratios in a flow of water-immiscible fluids inside microchannels. Each droplet represents a discrete trial testing different conditions. The system has been validated by crystallization of several water-soluble proteins.

Crystallization↗