PubMed Health⌕ Search

Biomedical subjects

Rute Almeida

Publications and source records attributed to Rute Almeida.

2 recordsLinked to original sources

QT variability and HRV interactions in ECG: quantification and reliability.

In this paper, a dynamic linear approach was used over QT and RR series measured by an automatic delineator, to explore the interactions between QT interval variability (QTV) and heart rate variability (HRV). A low-order linear autoregressive model allowed to separate and quantify the QTV fractions correlated and not correlated with HRV, estimating their power spectral density measures. Simulated series and artificial ECG signals were used to assess the performance of the methods, considering a respiratory-like electrical axis rotation effect and noise contamination with a signal-to-noise ratio (SNR) from 30 to 10 dB. The errors found in the estimation of the QTV fraction related to HRV showed a nonrelevant performance decrease from automatic delineation. The joint performance of delineation plus variability analysis achieved less than 20% error in over 75% of cases for records presenting SNRs higher than 15 dB and QT standard deviation higher than 10 ms. The methods were also applied to real ECG records from healthy subjects where it was found a relevant QTV fraction not correlated with HRV (over 40% in 19 out of 23 segments analyzed), indicating that an important part of QTV is not linearly driven by HRV and may contain complementary information.

Algorithms↗

A wavelet-based ECG delineator: evaluation on standard databases.

In this paper, we developed and evaluated a robust single-lead electrocardiogram (ECG) delineation system based on the wavelet transform (WT). In a first step, QRS complexes are detected. Then, each QRS is delineated by detecting and identifying the peaks of the individual waves, as well as the complex onset and end. Finally, the determination of P and T wave peaks, onsets and ends is performed. We evaluated the algorithm on several manually annotated databases, such as MIT-BIH Arrhythmia, QT, European ST-T and CSE databases, developed for validation purposes. The QRS detector obtained a sensitivity of Se = 99.66% and a positive predictivity of P+ = 99.56% over the first lead of the validation databases (more than 980,000 beats), while for the well-known MIT-BIH Arrhythmia Database, Se and P+ over 99.8% were attained. As for the delineation of the ECG waves, the mean and standard deviation of the differences between the automatic and manual annotations were computed. The mean error obtained with the WT approach was found not to exceed one sampling interval, while the standard deviations were around the accepted tolerances between expert physicians, outperforming the results of other well known algorithms, especially in determining the end of T wave.

Algorithms↗