Measuring acetylene concentrations using a frequency chirped continuous wave diode laser operating in the near infrared.

Two frequency chirped continuous wave diode lasers operating in the near infrared (IR) at wavelengths of lambda approximately 1.535 microm and lambda approximately 1.520 microm have been used to measure acetylene concentrations using the P(17) and R(9) rotational lines of the (nu1 + nu3) vibrational combination band. The diode lasers were frequency chirped by applying an electrical current pulse to the laser driver at a repetition rate of greater than 1 kHz. As the laser is operated at high repetition rates, more than 1000 spectra per second can, in principle, be acquired and summed, allowing fast accumulation of data, rapid averaging and consequent improvement of the signal to noise ratio and detection limit. Experiments were performed using a single-pass cell with a path length of 16.4 cm, and also an astigmatic multi-pass absorption cell aligned to give a path length of 56 m. Detection limits corresponding to minimum detectable absorption coefficients, alpha(min), of 5.6 x 10(-5) and 7.8 x 10(-8) cm(-1), respectively, were obtained over a 4 s detection bandwidth. These detection limits would correspond to mixing ratios of 21 parts per million by volume (ppmv) and 59 parts per billion by volume (ppbv) of acetylene at 1 atm in air, with the deleterious effects of pressure broadening accounted for. The single-pass cell was used to perform breakthrough volume (BTV) experiments for the low volume adsorbent traps used to pre-concentrate organic compounds in air, taking advantage of the capability of the system to measure concentrations in real time.

Journal Article↗

Combining preconcentration of air samples with cavity ring-down spectroscopy for detection of trace volatile organic compounds in the atmosphere.

Quantitative detection of small volatile organic compounds in ambient air is demonstrated using a combination of continuous wave cavity ring-down spectroscopy (cw-CRDS) and the preconcentration of air samples with an adsorbent trap. The trap consists of a zeolite molecular sieve, selected for efficient trapping of the test compounds ethene (ethylene) and ethyne (acetylene). Upon heating of the trap, these organic compounds desorb into a small-volume ring-down cavity, and absolute concentrations are measured by CRDS at 6150.30 cm(-1) (ethene) and 6512.99 cm(-1) (ethyne) without the need for calibration. The efficiency of the trapping and desorption was tested using commercial standard gas mixtures and shown to be 100% in the case of ethene, whereas some ethyne is retained under the current operating conditions. Samples of indoor and outdoor air were analyzed for ethene content, and measurements were made of mixing ratios as low as 6 ppbv. Removal of water vapor and CO(2) from the air samples prior to trapping was unnecessary, and the selectivity of the trapping, desorption, and spectroscopic detection steps eliminates the need for gas chromatographic separation prior to analysis. With anticipated improvements to the design, measurements of these and other trace atmospheric constituents should be possible on time scales of a few minutes.

Journal Article↗