Ryan T Kelly

Publications and source records attributed to Ryan T Kelly.

10 recordsLinked to original sources

Gradient-Elution Nanoflow Liquid Chromatography Without a Binary Pump: Smoothed Step Gradients Enable Reproducible, Sensitive, and Low-Cost Separations for Single-Cell Proteomics.

Mass spectrometry-based proteome profiling of trace analytes including single cells benefits from liquid chromatography separations operated at low flow rates (e.g., <50&#xa0;nl/min). However, high-pressure binary pumps needed to achieve such flow rates are not commercially available, and instead require splitting of the gradient flow to achieve low-nanoliter-per-minute flow rates. Gradient flow splitting can waste solvent and lead to flow inconsistencies. To address this, we have developed a method for creating gradients by combining segments of mobile phase having increasing solvent strength together in an open capillary, and then relying on Taylor dispersion to form the desired smooth gradient profile. Our method dramatically reduces costs, as only a single isocratic high-pressure pump is required. Following development of gradient profiles for both 10- and 20-min active gradients, we measured 200 pg injections of HeLa digest using a timsTOF mass spectrometer. Finally, we investigated differences in protein expression between single cells originating from two different colonies of ATG-KO HeLa cells. Thousands of proteins were quantified, and a potential mechanism explaining differential immune responses of these two colonies upon exposure to viral DNA treatment was determined.

Humans↗

Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

We have developed a new procedure for fabricating fused-silica emitters for electrospray ionization-mass spectrometry (ESI-MS) in which the end of a bare fused-silica capillary is immersed into aqueous hydrofluoric acid, and water is pumped through the capillary to prevent etching of the interior. Surface tension causes the etchant to climb the capillary exterior, and the etch rate in the resulting meniscus decreases as a function of distance from the bulk solution. Etching continues until the silica touching the hydrofluoric acid reservoir is completely removed, essentially stopping the etch process. The resulting emitters have no internal taper, making them much less prone to clogging compared to, e.g., pulled emitters. The high aspect ratios and extremely thin walls at the orifice facilitate very low flow rate operation; stable ESI-MS signals were obtained for model analytes from 5-microm-diameter emitters at a flow rate of 5 nL/min with a high degree of interemitter reproducibility. In extensive evaluation, the etched emitters were found to enable approximately four times as many LC-MS analyses of proteomic samples before failing compared with conventional pulled emitters. The fabrication procedure was also employed to taper the ends of polymer monolith-containing silica capillaries for use as ESI emitters. In contrast to previous work, the monolithic material protrudes beyond the fused-silica capillaries, improving the monolith-assisted electrospray process.

Hydrofluoric Acid↗

Phase-changing sacrificial materials for interfacing microfluidics with ion-permeable membranes to create on-chip preconcentrators and electric field gradient focusing microchips.

We have developed a novel approach for interfacing ionically conductive membranes with microfluidic systems using phase-changing sacrificial layers. Imprinted microchannels in a polymer substrate are filled with a heated liquid that solidifies at room temperature, a monomer solution is placed over the protected channels and polymerized to form a rigid semipermeable copolymer, and then the protective layer is melted and removed, leaving an open microchannel interfaced with a polymer membrane. We have applied this method in miniaturizing electric field gradient focusing (EFGF) and carrying out on-chip protein preconcentration. A semipermeable copolymer in the EFGF microchips fills a region of changing cross-sectional area, which allows a gradient in electric field to be established when an electrical potential is applied. Our technique provides microchip EFGF devices that offer 3-fold improved resolution in protein focusing compared with capillary-based systems. In addition, these EFGF microchips can separate peptide samples with resolution similar to what is obtained in capillary electrophoresis microdevices, and the micro-EFGF systems enrich analytes by a factor of >150. Finally, we have fabricated membrane-integrated microfluidic devices that can concentrate protein samples (R-phycoerythrin) over 10 000-fold to facilitate microchip capillary electrophoresis. Interfacing microchannels with ion-permeable membranes has great potential to enhance microchip analysis of biomolecules.

Electric Conductivity↗

Phase-changing sacrificial materials for solvent bonding of high-performance polymeric capillary electrophoresis microchips.

A new method for solvent bonding polymeric substrates to form microfluidic systems has been demonstrated. Prior to device sealing, channels in an embossed poly(methyl methacrylate) (PMMA) piece are filled with a heated liquid (paraffin wax) that forms a solid sacrificial layer at room temperature. The sacrificial material prevents the bonding solvent (acetonitrile) and softened PMMA from filling the channels. Once the sealing step is complete, the sacrificial layer is melted and removed, leaving enclosed microfluidic channels. We found that PMMA substrates welded together using this method could withstand internal pressures of >2250 psi, more than 1 order of magnitude higher than their thermally bonded counterparts. To demonstrate the usefulness of this method, microchip capillary electrophoresis (CE) devices in PMMA were created and tested. Amino acid and peptide mixtures were separated in <15 s, with >40,000 theoretical plates in a 2.5-cm separation distance. Electric fields as high as 1.5 kV/cm were applied in these microchips, and >300 CE runs were performed on a single device with no degradation of separation performance. The simplicity of the methods presented here and the improved robustness of the resulting devices should facilitate the broader implementation of polymer microchips in microfluidic analyses.

Acetonitriles↗

Field gradient electrophoresis.

The class of equilibrium gradient methods utilizes the opposition of two forces, at least one of which changes in magnitude with position, to separate and concentrate analytes. The drawback of many methods of this type is that the production of two opposing forces requires in comparison to standard methods, such as capillary electrophoresis, a relatively complex apparatus. In addition, for techniques such as electric field gradient focusing, hydrodynamic flow leads to Taylor dispersion, which limits the attainable concentration factor. We propose a new method, gradient field electrophoresis, which achieves analyte separation and focusing with only one spatially varying force, an electric field gradient. A model for the method is developed and used to analyze peak capacity. Experimental results for a protein (R-phycoerythrin) are given and compared to the model.

Electrophoresis↗

Electric field gradient focusing.

Electric field gradient focusing (EFGF) is a relatively new separation technique with promising attributes, particularly for protein analysis. The fundamental fractionation mechanism in EFGF involves a gradient in electric field along the length of a separation column. The electrophoretic force that drives charged analytes in a region of changing electric field is opposed by a constant, pressure-driven bulk fluid flow. When the electrophoretic velocity of a particular moiety is equal and opposite to the velocity of the fluid flow, the analyte focuses into a stationary band. Thus, EFGF can both concentrate and separate charged species according to electrophoretic mobility. To date, the electric field gradients needed for EFGF have been established using a number of different approaches, including channels having changing cross-sectional areas, conductivity gradients caused by the diffusion of buffer ions across a membrane, electrode arrays, and temperature gradients in buffers whose conductivities change as a function of temperature. EFGF has proven particularly effective for sample enrichment, with concentration factors of 10,000 reported. In this article we review advances in EFGF technology and discuss prospects for further improving EFGF for chemical analysis.

Isoelectric Focusing↗

Electric field gradient focusing of proteins based on shaped ionically conductive acrylic polymer.

Electric field gradient focusing (EFGF) is a separation technique that uses an electric field gradient and an opposing hydrodynamic flow to separate and concentrate charged analytes. This work describes miniaturized EFGF devices that are used for protein analysis. These devices employ a unique ionically conductive polymer that enables the required electric field gradient to be established. This polymer has good protein compatibility and allows the transport of small buffer ions while retaining large analytes such as proteins. With the use of an EFGF device, green fluorescent protein was concentrated 10 000-fold and the separation of a protein mixture was demonstrated. The development of these ionically conductive polymer-based devices represents a step toward making EFGF a useful analytical tool for proteomics investigations.

Ions↗

Fabrication of calcium fluoride capillary electrophoresis microdevices for on-chip infrared detection.

In this paper, we demonstrate microfluidic capillary electrophoresis (CE) devices made in CaF2 , for optical detection in a broad spectral range. We have designed methods for micromachining and enclosing capillaries in CaF2. The utility of these microdevices has been shown through CE analysis of fluorescently labeled amino acids. We have also performed infrared spectroscopy for analyte identification in microfluidic CaF2 channels. These CaF2 microdevices open the door to microchip separations with optical detection in the ultraviolet, visible, and infrared spectral regions.

Calcium Fluoride↗

Electrically actuated, pressure-driven microfluidic pumps.

In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.

Microcomputers↗

Thermal bonding of polymeric capillary electrophoresis microdevices in water.

A new method for thermally bonding poly(methyl methacrylate) (PMMA) substrates to form microfluidic systems has been demonstrated. A PMMA substrate is first imprinted with a Si template using applied pressure and elevated temperature to form microchannel structures. This embossing method has been used to successfully pattern over 65 PMMA pieces using a single Si template. Thermal bonding for channel enclosure is accomplished by clamping together an imprinted and a blank substrate and placing the assembly in boiling water for 1 h. The functionality of these water-bonded microfluidic substrates was demonstrated by performing high-resolution electrophoretic separations of fluorescently labeled amino acids. Testing of bond strength in four microdevices showed an average failure pressure of 130 kPa, which was comparable to the bond strength for devices sealed in air. Subsequent profilometry of separated substrates revealed that the dimensions of the channels were well preserved during the bonding process. This new methodology for generation of microfluidic constructs should facilitate the permanent incorporation of hydrated, molecular size-selective membranes in microdevices, thus circumventing problems associated with membrane swelling in microfluidic systems upon exposure to water.

Journal Article↗