Experimental evaluation of a MOSFET dosimeter for proton dose measurements.

The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations.

Biophysical Phenomena↗

Respiratory correlated segment reconstruction algorithm towards four-dimensional radiation therapy using carbon ion beams.

PURPOSE: To enhance the precision of treatment planning for tumors which move under respiration, we developed a respiratory-correlated segment reconstruction method (RS) based on the Feldkamp--Davis--Kress algorithm (FDK) which provides high temporal resolution and a high signal-to-noise ratio. We compared full-scan (FS-FDK) and RS-FDK with regard to dose distribution in heavy ion treatment planning. MATERIALS AND METHODS: Data acquisition for RS-FDK is done using a respiratory sensing system in cine scan mode with a 256-multi-detector row CT (256-MDCT). To evaluate the accuracy of irradiation of moving tumors, dose distributions with each algorithm were compared in heavy ion treatment planning using beam parameters obtained with FS-FDK. RESULTS: Images obtained using RS-FDK did not show motion artifacts and visualized the edges of the liver and pulmonary vessels more clearly than those with FS-FDK. The iso-dose distributions for FS-FDK covered the target volume; in contrast, RS-FDK with the beam parameter of FS-FDK image provided an insufficient dose to the target and a considerable dose to normal tissues around it. CONCLUSIONS: The information provided by RS-FDK improves accuracy in the prescription of dose-to-target volume. Further, RS-FDK allows greater precision in the delivery of radiotherapy, including 4D radiation therapy.

Aged↗

Physical evaluation of multidetector-row computed tomography (MDCT) scan methods and conditions for improvement of carbon beam distribution.

To reduce errors in the carbon beam distribution between the treatment planning system and the actual situation, we evaluated the geometrical accuracy, volume accuracy, water-equivalent length (WEL), and treatment planning, and compared the results of evaluation of axial and helical scan methods with various scan parameters. The results indicated that both scan methods showed good geometrical accuracy for thin slice images, but for thick slice images it is easier to understand the phantom as a sphere from the helical as compared with the axial scan. Treatment planning with a thin slice thickness (ST) provided accurate dose distribution for both scan methods, and the dose distribution on the treatment planning system was almost the same as that in the actual situation. Not all institutes, however, can obtain thin slice CT images, and some have used thick slice CT images in planning. For the axial scan, such thick slice images induced differences in dose distribution between treatment planning and the actual situation. Helical scans with a small, reconstructed increment reduced these differences even with relatively thick CT images. To achieve a more accurate dose distribution, radiation therapy planning should be performed using a thin ST for both scan methods or the helical scan with a small, reconstructed increment. Although we reached this conclusion using a carbon beam, it also may be applicable to proton beam therapy.

Carbon↗

Tumour shapes and fully automated range compensation for heavy charged particle radiotherapy.

The idea of a computer-controlled range-compensating system for heavy charged particle radiotherapy, the multibar compensator, is proposed. By stacking multiple energy-absorbing layers along the beam, each of which has structure and behaviour similar to those of a multileaf collimator, variable range compensation will be achieved. The analysis of the conventional range compensators actually used for treatment concluded that the proposed system would not seriously degrade the treatment quality for the most cases, except for tumours in the head and neck region where 1 mm precision may be required. The system will even be able to coexist with the conventional range compensators to provide either method depending on clinical situations.

Automation↗

Experimental evaluation of analytical penumbra calculation model for wobbled beams.

The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model.

Algorithms↗

Evaluation of a pencil beam algorithm for therapeutic carbon ion beam in presence of bolus.

Hot- and cold-dose spots at a shallow depth in a target are formed by carbon ions passing through the bolus with sharp gradients. These spots are caused by sidescatter disequilibrium due to various multiple scattering effects in the different bolus thicknesses. When the dose calculation method by the broad beam algorithm (BBA) is used for treatment planning, these spots cannot be predicted, because the BBA neglects the multiple scattering effects in materials (rms error of 3.9%). On the other hand, since the dose calculation method by the pencil beam algorithm (PBA) takes into account the scattering effects, the results calculated by the PBA agreed better than the BBA with the measured hot- and cold-dose spots, having a rms error of 1.9%. Thus, dose calculation by the PBA improves the accuracy of dose prediction at the shallow depth. However, since dose distributions at deeper positions are affected by many light fragment particles generated by fragment reactions, the results calculated by the PBA disagree with the experimental ones. It is necessary that even the PBA accurately models behavior of fragment particles.

Algorithms↗

Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations.

It is important for proton therapy to calculate dose distributions accurately in treatment planning. Dose calculations in the body for treatment planning are converted to dose distributions in water, and the converted calculations are then generally evaluated by the dose measurements in water. In this paper, proton dose calculations were realized for a phantom simulating a clinical heterogeneity. Both dose calculations in the phantom calculated by two dose calculation methods, the range-modulated pencil beam algorithm (RMPBA) and the simplified Monte Carlo (SMC) method, and dose calculations converted to dose distributions in water by the same two methods were verified experimentally through comparison with measured distributions, respectively. For the RMPBA, though the converted calculations in water agreed moderately well with the measured ones, the calculated results in the actual phantom produced large errors. This meant that dose calculations in treatment planning should be evaluated by the dose measurements not in water but in the body with heterogeneity. On the other hand, the results calculated in the phantom, even by the less rigorous SMC method, reproduced the experimental ones well. This finding showed that actual dose distributions in the body should be predicted by the SMC method.

Algorithms↗

A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning.

A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.

Adipose Tissue↗