PubMed Health⌕ Search

Biomedical subjects

Ryszard Lobinski

Publications and source records attributed to Ryszard Lobinski.

16 recordsLinked to original sources

Root-to-shoot long-distance circulation of nicotianamine and nicotianamine-nickel chelates in the metal hyperaccumulator Thlaspi caerulescens.

Plant metal hyperaccumulator species are widely used as models to unravel the heavy metal tolerance and hyperaccumulation mechanisms. Thlaspi caerulescens is capable of tolerating and hyperaccumulating Zn, Cd, and Ni. A search for factors involved in the cellular tolerance to Ni, based on yeast screens, led to isolation of a cDNA encoding a functional nicotianamine (NA) synthase (NAS). The T. caerulescens genome appears to contain a single copy of the NAS gene named TcNAS whose expression is restricted to the leaves. The analysis of dose-response and time-course Ni treatments have revealed that the exposure to Ni triggers the accumulation of NA in the roots. Because neither TcNAS expression nor NAS activity were detected in the roots, the NA accumulation in roots is most probably the result of its translocation from the leaves. Once in the roots, NA, together with Ni, is subsequently found in the xylem, for redirection to the aerial parts. Using liquid chromatography coupled to inductively coupled plasma or electrospray ionization mass spectrometry, it has been shown that part of the Ni is translocated as a stable Ni-NA complex in the xylem sap. This circulation of NA, Ni, and NA-Ni chelates is absent in the non-tolerant non-hyperaccumulator related species T. arvense. Taken together, the results provide direct physiological and chemical evidence for NA and NA-heavy metal complex translocation in a hyperaccumulator species.

Alkyl and Aryl Transferases↗

Uptake and speciation of selenium in garlic cultivated in soil amended with symbiotic fungi (mycorrhiza) and selenate.

The scope of the work was to investigate the influence of selenate fertilisation and the addition of symbiotic fungi (mycorrhiza) to soil on selenium and selenium species concentrations in garlic. The selenium species were extracted from garlic cultivated in experimental plots by proteolytic enzymes, which ensured liberation of selenium species contained in peptides or proteins. Separate extractions using an aqueous solution of enzyme-deactivating hydroxylamine hydrochloride counteracted the possible degradation of labile selenium species by enzymes (such as alliinase) that occur naturally in garlic. The selenium content in garlic, which was analysed by ICP-MS, showed that addition of mycorrhiza to the natural soil increased the selenium uptake by garlic tenfold to 15 microg g(-1) (dry mass). Fertilisation with selenate and addition of mycorrhiza strongly increased the selenium content in garlic to around one part per thousand. The parallel analysis of the sample extracts by cation exchange and reversed-phase HPLC with ICP-MS detection showed that gamma-glutamyl-Se-methyl-selenocysteine amounted to 2/3, whereas methylselenocysteine, selenomethionine and selenate each amounted to a few percent of the total chromatographed selenium in all garlic samples. Se-allyl-selenocysteine and Se-propyl-selenocysteine, which are selenium analogues of biologically active sulfur-containing amino acids known to occur in garlic, were searched for but not detected in any of the extracts. The amendment of soil by mycorrhiza and/or by selenate increased the content of selenium but not the distribution of detected selenium species in garlic. Finally, the use of two-dimensional HPLC (size exclusion followed by reversed-phase) allowed the structural characterisation of gamma-glutamyl-Se-methyl-selenocysteine and gamma-glutamyl-Se-methyl-selenomethionine in isolated chromatographic fractions by quadrupole time-of-flight mass spectrometry.

Enzymes↗

Capillary HPLC-ICP MS mapping of selenocompounds in spots obtained from the 2-D gel electrophoresis of the water-soluble protein fraction of selenized yeast.

A method based on ICP collision-cell MS detection in capillary HPLC was developed to gain an insight into the purity and identity of selenium-containing proteins separated by 1-D and 2-D electrophoresis. The bands and spots obtained after the separation of water-soluble proteins in selenized yeast were digested with trypsin prior to chromatography. Selenium could be detected down to the subpicogram level. The method, assisted by information obtained by MALDI TOF MS on the 5000 Da cut-off fraction, permitted the purity of bands and spots to be estimated and the efficiency of tryptic digestion and the quantity of selenium present in individual peptides to be evaluated. Owing to the high sensitivity and the lack of matrix suppression effects, the method provided chromatograms with signal-to-noise ratios of 10-1000 in conditions where the common ES Q-TOF MS detection failed.

Chromatography, High Pressure Liquid↗

Certification of a new selenized yeast reference material (SELM-1) for methionine, selenomethinone and total selenium content and its use in an intercomparison exercise for quantifying these analytes.

A new selenized yeast reference material (SELM-1) produced by the Institute for National Measurement Standards, National Research Council of Canada (INMS, NRC) certified for total selenium (2,059+/-64 mg kg(-1)), methionine (Met, 5,758+/-277 mg kg(-1)) and selenomethionine (SeMet, 3,431+/-157 mg kg(-1)) content is described. The +/-value represents an expanded uncertainty with a coverage factor of 2. SeMet and Met amount contents were established following a methanesulfonic acid digestion of the yeast using GC-MS and LC-MS quantitation. Isotope dilution (ID) calibration was used for both compounds, using 13C-labelled SeMet and Met. Total Se was determined after complete microwave acid digestion based on ID ICP-MS using a 82Se spike or ICP-OES spectrometry using external calibration. An international intercomparison exercise was piloted by NRC to assess the state-of-the-art of measurement of selenomethione in SELM-1. Determination of total Se and methionine was also attempted. Seven laboratories submitted results (2 National Metrology Institutes (NMIs) and 5 university/government laboratories). For SeMet, ten independent mean values were generated. Various acid digestion and enzymatic procedures followed by LC ICP-MS, LC AFS or GC-MS quantitation were used. Four values were based on species-specific ID calibration, one on non-species-specific ID with the remainder using standard addition (SA) or external calibration (EC). For total selenium, laboratories employed various acid digestion procedures followed by ICP-MS, AFS or GC-MS quantitation. Four laboratories employed ID calibration, the remaining used SA or EC. A total of seven independent results were submitted. Results for methionine were reported by only three laboratories, all of which used various acid digestion protocols combined with determination by GC-MS and LC UV. The majority of participants submitted values within the certified range for SeMet and total Se, whereas the intercomparison was judged unsuccessful for Met because only two external laboratories provided values, both of which were outside the certified range.

Chromatography, Liquid↗

Fractionation of selenium-containing proteins in serum by multiaffinity liquid chromatography before size-exclusion chromatography-ICPMS.

Immunoaffinity chromatography has been investigated for fractionation of serum into selenoalbumin and true selenoproteins. Among several albumin-depletion kits tested, a multiaffinity column specifically binding albumin and five other major serum proteins provided the best results. It extracted ca 95% of both albumin and selenoalbumin, which enabled interference-free determination of glutathione peroxidase, selenoprotein P, and selenoalbumin by size-exclusion chromatography combined with inductively coupled plasma mass spectrometry (SEC-ICPMS). The efficiency of the multiaffinity column did not vary over a period of 18 months. The purity of fractions separated by immunoaffinity LC was confirmed by elution-volume matching with standards in SEC-ICPMS and by selenopeptide mapping in capillary HPLC-ICPMS. Quantification of the selenium distribution among the different proteins in human serum from a control group and from a person on a selenium-rich diet revealed that 67% of the supplemented selenium was incorporated into albumin, 30% into glutathione peroxidase, and 3% into selenoprotein P.

Albumins↗

Development of a nebulizer for a sheathless interfacing of NanoHPLC and ICPMS.

A novel nebulizer (nDS-200) working at sample uptake rates of less than 500 nL min(-1) was developed for a sheathless interfacing of nanoHPLC (75-microm column i.d.) with ICPMS. It was based on a hollow fused-silica needle of which the tip (i.d. 10 microm, o.d. 20 microm) centered in a 254-microm-i.d. sapphire orifice. The nebulizer, equipped with a 3-cm(3) drain-free vaporization chamber, enabled a stable introduction into an ICP of aqueous mobile phases containing up to 95% acetonitrile at eluent flow rates between 50 and 450 nL min(-1). The low dead volume of the interface resulted in a peak width of 1.3 s (at half-height) and the entirely preserved chromatographic resolution. An example application of the coupling to the analysis of a tryptic digest of a SIP18 protein containing two to nine selenomethionine residues was described. The absolute detection limit was 25 fg (80Se), which allowed the detection of low-abundant selenopeptides at the femtomole level. In contrast to electrospray MS, the ICPMS detection in nanoHPLC is unaffected by the coeluting matrix and concomitant compounds and offers an elegant method for the detection and quantification of minor heteroelement-containing species prior to or in parallel with ESI MS analysis.

Chromatography, High Pressure Liquid↗

Analysis of the selenium species distribution in cow blood by size exclusion liquid chromatography-inductively coupled plasma collision cell mass spectrometry (SEC-ICPccMS).

A method for performing rapid semiquantitative screening of the distribution of Se species in the blood of cows fed with a diet enriched in selenized yeast was optimized. The method was based on direct injection of a blood sample onto a high resolution size exclusion chromatographic column and fractionation of the selenium species. Selenium was detected on-line by ICP-MS with a collision cell. The concentrations of selenized haemoglobin and free selenomethionine were estimated using the chromatogram. The method was applied to a study involving 15 control and 15 treated dairy cows at four different supplementation time points. The increase in the selenomethionine and selenized haemoglobin was a linear function of the total selenium concentration. A threshold value of 600 ng ml(-1) of total Se was established beyond which selenomethionine could not be incorporated into the protein. No inorganic selenium was found to be present. The total selenium in cow blood correlated well with that in milk. The selenium supplementation did not change the protein distribution profiles for other essential elements (Cu, Fe, Mn, Zn).

Animals↗

Determination of selenomethionine and selenocysteine in human serum using speciated isotope dilution-capillary HPLC-inductively coupled plasma collision cell mass spectrometry.

A method for the accurate determination of selenoamino acids in human serum by HPLC-ICPMS was developed using the species-specific isotope dilution analysis principle. A serum sample was enzymatically digested with a mixture of lipase and protease after derivatization of the selenocysteine residues with iodoacetamide. The selenoamino acid fraction was isolated by size exclusion LC followed by the separation of selenomethionine and the carboxymethylated selenocysteine by capillary HPLC. The isotope-specific determination of 77Se and 80Se was achieved on-line by ICP collision cell MS allowing the removal of polyatomic interferences. Quantification was carried out by isotope dilution using a 77Se-labeled selenomethionine spike and the determination of the 77Se/80Se ratio in the cHPLC selenomethionine peak. The accurately determined selenomethionine was used as an internal standard for the selenocysteine determination from the same chromatogram. The modification of the previously developed cHPLC-ICPMS interface allowed the reduction of the absolute detection limits twice (down to the 75-fg level), which resulted in the lowest ever reported procedural detection limits (below 0.5 ng g(-1) for a 450-mg serum sample). The precision was less than 5% RSD. The method was validated by the mass balance of selenium (amino acid incorporated vs total).

Chromatography, Gel↗

Is Ag(I) an adequate probe for Cu(I) in structural copper-metallothionein studies? The binding features of Ag(I) to mammalian metallothionein 1.

The binding abilities of silver(I) to mammalian MT 1 have been studied and compared with those of copper(I), recently reported [Bofill et al. (2001) J Biol Inorg Chem 6:408-417], with the aim of analyzing the suitability of Ag(I) as a Cu(I) probe in Cu-MT studies. The Zn/Ag replacement in recombinant mouse Zn(7)-MT 1 and corresponding Zn(4)-alphaMT 1 and Zn(3)-betaMT 1 fragments, as well as the stepwise incorporation of Ag(I) to the corresponding apo-MTs, have been followed in parallel by various spectroscopic techniques including electronic absorption (UV-vis), circular dichroism (CD) and electrospray mass spectrometry coupled to capillary zone electrophoresis (CZE-ESI-MS). A comparative analysis of the sets of data obtained in the titration of Zn(7)-MT 1, Zn(4)-alphaMT 1 and Zn(3)-betaMT 1 with AgClO(4) at pH 7.5 and 2.5 has led to the reaction pathways followed during the incorporation of silver to these proteins under these specific conditions, disclosing unprecedented stoichiometries and structural features for the species formed. Thus, the Zn/Ag replacement in Zn(7)-MT 1 at pH 7.5 has revealed the subsequent formation of Ag(4)Zn(5)-MT, Ag(7)Zn(3)-MT, Ag(8)Zn(3)-MT, Ag(10)Zn(2)-MT, Ag(12)Zn(1)-MT, Ag(x)-MT, x=14-19, whose structure consists of two additive domains only if Zn(II) remains coordinated to the protein. A second structural role for Zn(II) has been deduced from the different folding found for the Ag(x)-MT species of the same stoichiometry formed at pH 7.5 or 2.5. Comparison of the binding features of Cu(I) and Ag(I) to the entire MT at pH 7.5 shows that, among all the micro(x)Zn(y)-MT (0<or= y<7) species found, only M(I)(4)Zn(5)-MT [(Zn(4))(alpha)(micro(4)Zn(1))(beta)] and M(I)(7)Zn(3)-MT [(micro(3)Zn(2))(alpha)(micro(4)Zn(1))(beta)], which form during the first stages of the Zn(II)/M(I) metal replacement, show comparable 3D structures; thus, they are the only species where Ag(I) ions can be predicted to be an adequate probe for Cu(I).

Animals↗

Identification of water-soluble selenium-containing proteins in selenized yeast by size-exclusion-reversed-phase HPLC/ICPMS followed by MALDI-TOF and electrospray Q-TOF mass spectrometry.

An approach to speciation of selenium incorporated in yeast proteins was developed. The tryptic digest of a water-soluble protein fraction isolated by size-exclusion chromatography was analyzed by reversed-phase HPLC/ICPMS. The selenopeptides selected owing to the detector's elemental specificity were then analyzed by MALDI-TOFMS in order to select target ions for collision-induced dissociation MS. The latter, carried out with an electrospray Q-TOF spectrometer, enabled the sequencing of the selenopeptides detected by HPLC/ICPMS. The approach allowed for the first time the identification of a family of Se-containing proteins resulting from the replacement by selenomethionine of 2-9 methionine residues in a salt-stress-induced protein SIP18 (Mr 8874). The presence of these proteins was confirmed by MALDI-TOFMS of the original (nondigested) protein fraction. Another selenium protein identified was a heat-shock protein HSP12 (Mr 11693) in which the only methionine residue was replaced by selenomethionine. These two Se-containing proteins accounted for more than 95% of selenium in the water-soluble protein fraction.

Amino Acid Sequence↗

Detection of selenocompounds in a tryptic digest of yeast selenoprotein by MALDI time-of-flight MS prior to their structural analysis by electrospray ionization triple quadrupole MS.

MALDI-TOFMS was proposed as a key technique to a novel generic approach for the speciation analysis of selenium in yeast supplements. Owing to a lower detection limit and superior matrix tolerance to electrospray MS it allowed a successful detection of selenocompounds in samples for which electrospray MS had failed. The analytical approach developed was applied to the identification of a previously unreported selenopentapeptide (m/z 596) in the tryptic digest of a water-soluble selenoprotein fraction isolated by size-exclusion chromatography. The information on the mass of the protonated molecular ion obtained from MALDI allowed the optimization of the conditions for collision induced dissociation MS using a triple quadrupole spectrometer that enabled the determination of the amino acid sequence SeMet-Asn-Ala-Gly-Arg of the selenopeptide.

Dietary Supplements↗

Characterization of arsenic species in kidney of the clam Tridacna derasa by multidimensional liquid chromatography-ICPMS and electrospray time-of-flight tandem mass spectrometry.

The identification of water-soluble arsenic species in a kidney of the Tridacna clam by electrospray quadrupole/time-of-flight mass spectrometry (ES Q-TOF MS) was investigated. The species were isolated by three-dimensional LC (size exclusion-anion exchange-cation exchange); the elution of arsenic was monitored by ICPMS. The average accuracy and precision of the molecular mass measurements, studied for a number of organoarsenic standards, were 22 (negative bias) and 15 ppm, respectively. Structural information was obtained in the tandem Q-TOF mode. A total of 15 organoarsenic species were identified, and 13 of these possessed the dimethylarsinoyl group (8 ribofuranosides, 4 acyclic compounds, and 1 dihydroxyfuran). Four of these species were previously unreported. Arsenobetaine and dimethylarsinic acid were also detected. The major species (accounting for up to 50% water-soluble arsenic) was 5-dimethylarsinoyl-2,3,4-trihydroxypentanoic acid. The metabolic interrelationships of these compounds and their significance are briefly discussed.

Animals↗

Investigation of metal complexes with metallothionein in rat tissues by hyphenated techniques.

The potential of hyphenated techniques based on a combination of microbore reversed-phase (RP) HPLC or capillary zone electrophoresis (CZE) with inductively coupled plasma (ICP) or electrospray (ES) mass spectrometry (MS) was demonstrated for the characterization of metal complexes with metallothionein in rat liver and kidney. The mixture of MT complexes was isolated from the tissues by size-exclusion LC and further characterized in neutral pH conditions (pH 6.8-7.2) by RP-HPLC or CZE. The metal stoichiometry and the molar mass of the eluted complexes was measured by ICP-MS and ES-MS, respectively. An additional dimension to the analysis was achieved by post-column acidification of the chromatographic eluent that allowed the determination of the molecular weight of the demetallated complexes with 10-fold higher sensitivity. The approach allowed the detection of two major metallothionein (MT) isoforms (MT-1 and MT-2) in liver and one MT isoform in kidney. The actual number of peaks in chromatograms and electropherograms was bigger because of the formation of mixed Cd-Cu complexes of the same MT isoform that showed different hydrophobicities.

Animals↗

Speciation of seleno compounds in yeast aqueous extracts by three-dimensional liquid chromatography with inductively coupled plasma mass spectrometric and electrospray mass spectrometric detection.

A three-dimensional liquid chromatographic purification protocol based on sequential size-exclusion, anion-exchange and cation-exchange separation mechanisms was developed for the mapping of seleno compounds in aqueous yeast extracts. The method allowed the demonstration of the presence of more than 30 different seleno compounds. Semi-preparative size-exclusion and anion-exchange chromatography were optimized for maximum resolution using electrospray-compatible buffers in order to purify the compounds for mass spectrometric analysis. Molecular masses were attributed to many of the compounds on the basis of the selenium isotopic pattern in the electrospray mass spectra and of the collision-induced fragmentation patterns. Limitations preventing the ultimate identification of the selenium species detected are discussed.

Chromatography, Liquid↗