PubMed Health⌕ Search

Biomedical subjects

Ryuichi Yoneyama

Publications and source records attributed to Ryuichi Yoneyama.

7 recordsLinked to original sources

Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model.

Optical coherence tomography (OCT) is an optical analog of mechanical intravascular ultrasound (M-IVUS) with much higher spatial resolution. However, no data exist regarding the nonuniform rotational distortion (NURD) with OCT. The aim of the study was to investigate whether OCT generates less NURD relative to M-IVUS. A coronary artery phantom model was constructed with a rubber ring (3.68 mm in diameter), located at the distal end of the phantom. This model was also composed of eight equally spaced steel wires and an additional marker-wire. Two types of vascular phantoms were used, mild curve (90 degrees ) and acute curve (near 180 degrees ). Subsequent M-IVUS (n = 6) and OCT (n = 6) imaging was performed. Eight angles between eight wires, except the marker-wire, were measured from each image. These angles, measured with M-IVUS and OCT, were compared with those of high-resolution optical photography as a gold standard. The average in angle differences was significantly smaller in OCT compared with M-IVUS in the mild curve model (3.2 +/- 1.0 degrees vs, 6.9 +/- 2.1 degrees , p < 0.01). Compared with the latter model, the average in angle differences was exaggerated in the acute curve model with M-IVUS (9.1 +/- 0.9 degrees vs. 6.9 +/- 2.1 degrees , p < 0.05) but not with OCT (3.5 +/- 0.8 degrees vs. 3.2 +/- 1.0 degrees , p= not significant). OCT generates significantly less NURD compared with M-IVUS, especially in tortuous situation.

Artifacts↗

Magnetic resonance assessment of myocardial perfusion via catheter-based ventricle-coronary vein bypass in porcine myocardial infarction model.

OBJECTIVE: The goal of this study was to investigate the efficacy of VPASS with physiological measurements, magnetic resonance imaging (MRI), and histology in a porcine model of myocardial infarction. BACKGROUND: A catheter-based ventricle-to-coronary vein bypass (VPASS) has been proposed as a potential treatment strategy for refractory coronary artery disease patients. METHODS: In an acute setting, the VPASS implant was deployed percutaneously in three swine. The partial pressure of oxygen (PO(2)) in the anterior interventricular vein (AIV) and left ventricle (LV) were measured before and after VPASS implant with various combinations of balloon occlusion in the AIV and left anterior descending artery (LAD). In a separate chronic study, the VPASS procedure was completed on three swine with a mid-LAD occlusion. Thirty days post-VPASS procedure, angiography, contrast-enhanced MRI, and histology were performed to assess myocardial viability. Perfusion was analyzed using the average percent signal intensity change (APSIC) in the anterior walls (AW) and inferior walls (IW). RESULTS: The VPASS implant was performed without complication. Post-VPASS implantation, the distal AIV PO(2) increased up to the LV PO(2) level during simultaneous AIV and LAD blockage (432 +/- 24 mmHg). At day 30, quantitative perfusion analysis demonstrated no difference in APSIC between AW and IW (125 +/- 26% vs. 137 +/- 38%, P = 0.46). Delayed enhancement and histology showed focal subendomyocardial infarction. CONCLUSIONS: VPASS implant with simultaneous AIV and LAD occlusion allows perfusion of oxygenated blood to the distal AIV, which in the setting of an acute myocardial infarction model was capable of rescuing most of the myocardium at risk.

Animals↗

Catheter-based ventricle-coronary vein bypass.

The goal of this study was to investigate the feasibility of a catheter-based ventricle-to-coronary vein bypass (VPASS) in order to achieve retrograde myocardial perfusion by a conduit (VSTENT) from the left ventricle (LV) to the anterior interventricular vein (AIV). Percutaneous coronary venous arterialization has been proposed as a potential treatment strategy for otherwise untreatable coronary artery disease. In an acute setting, the VSTENT implant was deployed percutaneously using the VPASS procedure in five swine. Coronary venous flow and pressure patterns were measured before and after VSTENT implant deployment with and without AIV and left anterior descending artery (LAD) occlusion. In a separate chronic pilot study, the VPASS procedure was completed on two animals that had a mid-LAD occlusion or LAD stenosis. At day 30 post-VPASS procedure, left ventriculography and magnetic resonance imaging (MRI) were performed to assess the patency and myocardial viability of the VSTENT implants. Pre-VSTENT implantation, the mid-AIV systolic wedge pressure was significantly lower than LV systolic pressure during AIV blockage (46 +/- 19 vs. 90 +/- 16 mm Hg; P < 0.01). The VSTENT implant deployment was performed without complication and achieved equalization of the AIV and LV systolic pressures and creation of retrograde flow in the distal AIV (maximal flow velocity: 37 +/- 7 cm/sec). At day 30 post-VPASS procedure, left ventriculography showed VSTENT implant patency. MRI perfusion images demonstrated myocardial viability even with an LAD occlusion. Coronary retrograde perfusion using the VPASS procedure is feasible and may represent a potential technique for end-stage myocardial ischemia.

Animals↗

Tracking stem cells in the cardiovascular system.

Stem cells are a promising approach to cardiovascular therapeutics. Animal experiments have assessed the fate of injected stem cells through ex vivo methods on sacrificed animals. Approaches are needed for in vivo tracking of stem cells. Various imaging techniques and contrast agents for stem cell tracking will be reviewed.

Animals↗

In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound.

Optical coherence tomography (OCT) is limited as an intravascular imaging tool because of interference with blood. This study tested a new balloon occlusion-flushing catheter for OCT scanning of stented coronary arteries and compared stent measurements between OCT and intravascular ultrasound (IVUS). Motorized pullback with OCT and IVUS was examined in coronary stents deployed in swine. Quantitative measurements were obtained and compared between both groups. In addition, stent strut thickness was compared among OCT, IVUS and actual measurement. The occlusion catheter successfully provided motorized pullback OCT images in the stented coronary arteries without any complications. There were no differences in calculated lumen volume. However, stent volumes were significantly smaller with OCT than with IVUS (p < 0.05). OCT significantly underestimated the stent strut thickness compared with the actual measurement. Although OCT underestimates the stent strut thickness, motorized pullback OCT imaging with the occlusion catheter can provide appropriate in-stent images in the porcine coronary arteries.

Animals↗

Catheter-based antegrade intracoronary viral gene delivery with coronary venous blockade.

The purpose of this study is to evaluate the feasibility of percutaneous antegrade myocardial gene transfer (PAMGT). A consistent and safe technique for in vivo gene transfer is required for clinical application of myocardial gene therapy. PAMGT with concomitant coronary venous blockade was performed in 12 swine. The myocardium was preconditioned with 1 min of occlusion of the left anterior descending and left circumflex arteries. The anterior interventricular vein was occluded during left anterior descending artery delivery, and the great cardiac vein at the entrance of the middle cardiac vein was occluded during left circumflex artery delivery. With arterial and venous balloons inflated (3 min) and after adenosine (25 mug) injection, PAMGT was performed by antegrade injection of an adenoviral solution (1 ml of 10(11) plaque-forming units in each coronary artery) carrying beta-galactosidase or saline through the center lumen of the angioplasty balloon. In one set of animals, PAMGT was performed with selective coronary vein blockade (n = 9); in another set of animals, PAMGT was performed without coronary vein blockade (n = 5). At 1 wk after gene delivery, the animals were killed. Quantitative beta-galactosidase analysis was performed in the left and right ventricular walls. PAMGT was successfully performed in all animals with and without concomitant occlusion of the coronary veins. Quantitative beta-galactosidase analysis showed that PAMGT with coronary blockade was superior to PAMGT without coronary blockade. beta-Galactosidase activity increased significantly in the beta-galactosidase group compared with the saline group: 1.34 +/- 0.18 vs. 0.81 +/- 0.1 ng (P </= 0.01) in the left ventricular wall and 0.91 +/- 0.1 vs. 0.66 +/- 0.07 ng (P </= 0.05) in the right ventricular wall. PAMGT with selective coronary venous blockade is feasible, reproducible, and safely achieved in a large-animal model.

Adenoviridae↗

Introduction of autopsy imaging redefines the concept of autopsy: 37 cases of clinical experience.

A new autopsy imaging (AI) system was introduced at the Research Center Hospital for Charged Particle Therapy (RCCPT) in January 2000. Autopsy imaging is a postmortem and preautopsy diagnostic procedure using magnetic resonance imaging (MRI). Scanning is performed with a 1.5 Tesla MRI system before autopsy. The AI results are reported to the pathologist and, in light of this information, autopsy is performed with minute precision. Autopsy imaging was performed on 37 cancer cases. In seven cases, AI was less informative than the autopsy, but in 30 cases, more precise reports on the final diagnosis were available with the combined application of autopsy and AI than autopsy alone, particularly in eight limited autopsy cases. Thus, AI provides critical and supplementary information for autopsy; furthermore, AI itself is a unique imaging system of great importance.

Aged↗