Development and optimization of a 2-hydroxyethylacrylate MRI polymer gel dosimeter.

In this study, radiation induced changes in a polymer gel dosimeter manufactured using 2-hydroxyethylacrylate (HEA) and N,N'-methylene-bisacrylamide (BIS) were investigated using magnetic resonance imaging (MRI) and FT-Raman spectroscopy. The variation in magnetic resonance relaxation time (T2) with absorbed dose was modelled assuming fast exchange of magnetization. Overall good agreement between the model and experimental data was obtained. However, comparison with FT-Raman data suggests that not all the protons attached to the polymer contribute to the relaxation process. Furthermore, for certain compositions improved agreement with experimental data was achieved when a lower fraction of polymer protons available for exchange with water was assumed in the low dose region. This indicates that the T2 value is influenced by the composition and topology of the formed polymer, which may vary with absorbed dose. The concept of percentage dose resolution (Dp delta, %) was introduced to enable optimization of gel compositions for use in relative dosimetry applications. This concept was applied to demonstrate the effects of varying the gelatine concentration, the total fraction of monomer/crosslinker (%T) and the relative fraction of crosslinker (%C) on gel performance in HEA gels as well as compare the performance of HEA and a standard polyacrylamide gel (PAG). The percentage dose resolution was improved for all HEA gels compared to the PAG dosimeter containing 3% acrylamide and 3% BIS. Increasing the total concentration of monomer was shown to have the largest single effect. In the range of doses of interest for clinical radiation therapy, Dp delta, % for the optimal HEA gel (4% HEA, 4% BIS) was lower than 2.3%, compared to 3.8% for the PAG dosimeter.

Acrylamides↗

Simple methods for the correction of T2 maps of phantoms.

Two simple methodologies for correcting the errors in T2 maps for phantom measurements are presented; they both give accurate MRI maps with a low coefficient of variation (CV). The rate correction method is based on an equation relating the true T2 (T2,t) and that determined experimentally (T2,exp) for homogenous phantoms. The response matrix method is a phenomenological analysis of the difference between T2,exp and T2,t, from which correction factors are computed for a range of T2 values and for every pixel of an image. The factors were obtained from phantoms filled with a homogeneous gelatin gel and having different T2,t values. The CV in homogeneous phantom measurements were reduced from 2.5-4.0% to approximately 0.6-2.0% for T2,t values ranging from 180-600 ms. Examples are shown for the correction of T2 maps of phantoms filled with polymer dosimeter gel irradiated with photon beams from a linear accelerator. The methodologies presented can easily be implemented on a clinical MRI scanner.

Humans↗

Dose resolution optimization of polymer gel dosimeters using different monomers.

Polymer gel dosimeters of different formulations were manufactured from different monomers of acrylamide, acrylic acid, methacrylic acid, 1-vinyl-2-pyrrolidinone, 2-hydroxyethyl methacrylate and 2-hydroxyethyl acrylate. Gelatin and agarose were used as the gelling agents and N,N'-methylene-bis-acrylamide was used as a co-monomer in each polymer gel dosimeter. The T2 dependence of each dosimeter was analysed using a model of fast exchange of magnetization. The influence of the half-dose and the apparent T2 of the polymer-proton pool on the dose resolution (Dpdelta) were examined. Comparisons are made with the commonly employed R2-dose sensitivity. Differences exist suggesting that experiments reported in the literature using what were thought to be more optimal dosimeters may not actually be so. Based on Dpdelta of each formulation, conclusions are drawn on the optimal formulation required for a specific range of absorbed doses. In addition, information about the extent of polymerization of the monomers used along with some characteristics of the polymer network formed are reported. The influence of the concentration of monomers and gelling agent was subsequently evaluated using a model of fast exchange of magnetization. Based on these calculations, further improvement in Dpdelta can be expected.

Acrylamide↗

Modelling of post-irradiation events in polymer gel dosimeters.

The nuclear magnetic resonance (NMR) spin-spin relaxation time (T2) is related to the radiation-dependent concentration of polymer formed in polymer gel dosimeters manufactured from monomers in an aqueous gelatin matrix. Changes in T2 with time post-irradiation have been reported in the literature but their nature is not fully understood. We investigated those changes with time after irradiation using FT-Raman spectroscopy and the precise determination of T2 at high magnetic field in a polymer gel dosimeter. A model of fast exchange of magnetization taking into account ongoing gelation and strengthening of the gelatin matrix as well as the polymerization of the monomers with time is presented. Published data on the changes of T2 in gelatin gels as a function of post-manufacture time are used and fitted closely by the model presented. The same set of parameters characterizing the variations of T2 in gelatin gels and the increasing concentration of polymer determined from FT-Raman spectroscopy are used successfully in the modelling of irradiated polymer gel dosimeters. Minimal variations in T2 in an irradiated PAG dosimeter are observed after 13 h.

Acrylic Resins↗

An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography.

Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comonomer concentration increases the CT-dose sensitivity of the polymer gel dosimeter. This can be further increased by replacing gelatin with agarose. Varying the gelatin concentration however does not significantly change the CT-dose sensitivity. Among the compositions studied, dose resolution (D(delta)95%) was found to be optimal for polymer gel dosimeters comprising 5% gelatin, 3% AA, 3% BIS and 89% water.

Acrylamide↗

Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence.

In polymer gel dosimetry using magnetic resonance imaging, the uncertainty in absorbed dose is dependent on the experimental determination of T2. The concept of dose resolution (Dpdelta) of polymer gel dosimeters is developed and applied to the uncertainty in dose related to the uncertainty in T2 from a range of T4 encountered in polymer gel dosimetry. Dpdelta is defined as the minimal separation between two absorbed doses such that they may be distinguished with a given level of confidence, p. The minimum detectable dose (MDD) is Dpdelta as the dose approaches zero. Dpdelta and the minimum detectable dose both give a quantifiable indication of the likely practical limitations and usefulness of the dosimeter. Dpdelta of a polyacrylamide polymer gel dosimeter is presented for customized 32-echo and standard multiple-spin-echo sequences on a clinical MRI scanner. In evaluating uncertainties in T2, a parameter of particular significance in the pulse sequence is the echo spacing (ES). For optimal results, ES should be selected to minimize Dpdelta over a range of doses of interest in polymer gel dosimetry.

Biophysical Phenomena↗

The relationship between radiation-induced chemical processes and transverse relaxation times in polymer gel dosimeters.

The effects of ionizing radiation in different compositions of polymer gel dosimeters are investigated using FT-Raman spectroscopy and NMR T2 relaxation times. The dosimeters are manufactured from different concentrations of comonomers (acrylamide and N,N'-methylene-bis-acrylamide) dispersed in different concentrations of an aqueous gelatin matrix. Results are analysed using a model of fast exchange of magnetization between three proton pools. The fraction of protons in each pool is determined using the known chemical composition of the dosimeter and FT-Raman spectroscopy. Based on these results, the physical and chemical processes in interplay in the dosimeters are examined in view of their effect on the changes in T2. The precipitation of growing macroradicals and the scavenging of free radicals by gelatin are used to explain the rate of polymerization. The model describes the changes in T2 as a function of the absorbed dose up to 50 Gy for the different compositions. This is expected to aid the theoretical design of new, more efficient dosimeters, since it was demonstrated that the optimum dosimeter (i.e, with the lowest dose resolution) must have a range of relaxation times which match the range of T2 values which can be determined with the lowest uncertainty using an MRI scanner.

Dose-Response Relationship, Radiation↗

Dose response characteristics and basic dose distribution data for a polymerization-based dosemeter gel evaluated using MR.

A safe and reproducible mixing procedure for the manufacture of a polymerization-based dosemeter gel evaluated using MRI (PoMRI) is presented. The dose response, obtained by irradiating gel-filled vials with absorbed doses in the interval 0-20 Gy and evaluated with respect to 1/T2, was found to be linear in the interval 0-8 Gy, with a sensitivity of 0.211 s-1Gy-1 (r2 = 0.998) at 1.5 T. Evaluation of the same set of vials with respect to 1/T1 gave a sensitivity of 0.018 s-1Gy-1 (r2 = 0.960). PoMRI and diode data were compared for standard photon and electron treatment beams. A deviation of less than 3% was found between the two methods for central depth dose curves as well as dose profiles (2 mm for electrons in the steep dose gradient regions). The importance of the method used for background correction for the reliability of the results was also evaluated. Barex (with a wall thickness of 1.5 mm) was investigated for use as phantom material and found to be favourable compared with glass. The results obtained in this study show that PoMRI has excellent potential as a 3D detector.

Dose-Response Relationship, Radiation↗

MRI image plane nonuniformity in evaluation of ferrous sulphate dosimeter gel (FeGel) by means of T1-relaxation time.

MR image nonuniformity can vary significantly with the spin-echo pulse sequence repetition time. When MR images with different nonuniformity shapes are used in a T1-calculation the resulting T1-image becomes nonuniform. As shown in this work the uniformity TR-dependence of the spin-echo pulse sequence is a critical property for T1 measurements in general and for ferrous sulfate dosimeter gel (FeGel) applications in particular. The purpose was to study the characteristics of the MR image plane nonuniformity in FeGel evaluation. This included studies of the possibility of decreasing nonuniformities by selecting uniformity optimized repetition times, studies of the transmitted and received RF-fields and studies of the effectiveness of the correction methods background subtraction and quotient correction. A pronounced MR image nonuniformity variation with repetition and T1 relaxation time was observed, and was found to originate from nonuniform RF-transmission in combination with the inherent differences in T1 relaxation for different repetition times. The T1 calculation itself, the uniformity optimized repetition times, nor none of the correction methods studied could sufficiently correct the nonuniformities observed in the T1 images. The nonuniformities were found to vary considerably less with inversion time for the inversion-recovery pulse sequence, than with repetition time for the spin-echo pulse sequence, resulting in considerably lower T1 image nonuniformity levels.

Background Radiation↗

Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements.

Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.

Calibration↗

Verification of single beam treatment planning using a ferrous dosimeter gel and MRI (FeMRI).

A method for analysing and comparing treatment planning system (TPS) data and ferrous dosimeter gel measurements evaluated with MRI (FeMRI) was developed, including image processing to final absorbed dose images. Measurements were analysed according to this method and FeMRI data were thereby compared with the TPS-calculated dose distribution. For photons, differences between FeMRI- and TPS dose data were mainly within +/- 2%. Minor shortcomings found in both the FeMRI system and the TPS are explained and discussed. For electron beams, there was an overall good agreement. It was found that the TPS underestimates the lateral scattering dose outside the primary beam, but the reported dose difference corresponds to a small spatial deviation (less than 2 mm). It is important to consider this single beam data comparison when the method is extended to more complicated situations, for example when using several beams.

Ferrous Compounds↗