Comprehensive scheme for detection of ventricular fibrillation for implantable cardioverter defibrillators.

Implantable cardioverter defibrillators (ICDs) detect and defibrillate ventricular fibrillation (VF) and ventricular tachycardia (VT). Other therapies which use less energy are also available to terminate VT. Previous studies have shown that ICD rate schemes often misdiagnose VT as VF. In this study, an improved VF classification scheme was designed and tested, which employs the classic rate criteria plus paired signal concordance (PSC); PSC uniquely detects VF where VT and VF rates overlap (220-340 ms). Two signals from a bipolar pair (1 cm) recorded in a unipolar sense exhibit similar signal shape for concordant rhythms, such as sinus rhythm and VT, and disconcordance for VF. Once the rate criterion is met, PSC is measured by the peak normalized cross-correlation coefficient calculated over the depolarization. Variability, measured by a modified range, determined the contextual diagnosis over a passage. Sinus rhythm (20), VT (12), VF (22), atrial fibrillation (10), sinus rhythm with ventricular premature depolarizations (7), and polymorphic VT (4) passages were recorded from 38 patients. Rate-PSC was tested with unfiltered, digitized signals (1-500 Hz, 1,000 samples per second) and with filtered, downsampled signals (1-50 Hz, 100 samples per second). Sensitivity values, or percentage of correct VF detection, and specificity values, or detection of all other rhythms, were generated and compared with simulations of three commercial ICDs programmed to similar settings as rate-PSC and to nominal settings. The sensitivity values for rate-PSC with unfiltered and with filtered signals and for ICDs with 220 ms and with nominal settings were 100%, 100%, 48-80%, and 100%, respectively; the corresponding specificity values were 95%, 83%, 93%, and 7-13%, respectively. It was concluded that the rate-PSC scheme was able to reliably separate VF from other rhythms, even rhythms that have a variable morphology or variable rate. With the confidence of accurate VF detection, use of low-energy therapies for non-VF rhythms will increase device longevity and enhance patient comfort.

Computer Simulation↗

Augmented two-channel arrhythmia detection: an efficient diagnostic method for implantable devices.

ICDs are highly effective in preventing sudden cardiac death. However, inappropriate device shocks caused by false-positive diagnoses are estimated to happen in 20% of all patients. The need for implantable electrical devices to detect with precision arrhythmias requiring therapy has spawned a variety of proposals for better means of tachycardia identification. To address this problem, the augmented two-channel arrhythmia detection (A2CAD) algorithm, a real-time scheme utilizing timing and morphology from both the atrial and ventricular channels, is introduced. The algorithm uses rate detection as a first stage and augments this with morphological signal analysis in rhythms that confound the rate only diagnoses. The software executes in real-time (online), and has been tested on 60 passages of two-channel intracardiac signals. The following arrhythmias constituted the test set: 10 AF and/or atrial flutter; 15 SVT; 16 VT; 10 ventricular flutter or VF; 5 sinus tachycardia; and 4 cases of AF concurrent with VF. Results from 60 patient cases indicate 57 (95%) of 60 success rate for A2CAD, validating its potential for implementation in future implantable devices.

Algorithms↗

Automated analysis of spontaneously occurring arrhythmias by implantable devices. Limitations of using rate and timing features alone.

Real-time automated systems for arrhythmia analysis by implantable antitachycardia devices have been designed to incorporate two-channel rate criteria with intracavitary atrial and ventricular electrogram morphology. Because the power requirements for morphologic analysis substantially limit antitachycardia device longevity, the authors sought to develop an alternative algorithm that relies solely on rate and three newly developed timing features: onset (median ventricular rate filtering to detect abrupt onset), loss of atrioventricular (AV) sequency (premature ventricular depolarizations), and regularity-multiplicity (minimal median cycle length variation concurrent with integral [n:1] AV periodicity). This system was assessed using spontaneously occurring arrhythmias in patients undergoing electrophysiology studies. Electrograms were captured on FM tape (1-500 Hz) using biopolar catheters in the high right atrium and the left ventricular apex. In 11 patients, 25 distinct arrhythmias were analyzed, which included sinus tachycardia (ST) (1 passage), supraventricular tachycardia (SVT) (6 passages), ventricular tachycardia (VT) with concurrent sinus rhythm (16 passages), VT with concurrent atrial flutter (VT/AFl) (2 passages), and ventricular fibrillation (VF) (1 passage). The algorithm correctly diagnosed 1 of 1 episode of ST, 4 of 6 episodes of SVT, 15 of 16 episodes of VT with concurrent sinus rhythm, 0 of 2 episodes of VT/AFl, and 1 of 1 episode of VF. Ventricular tachycardia episodes were misdiagnosed as SVT because of absence of loss of AV sequency in VT onset (1 episode), presence of multiplicity between VT and AFl (1 episode), and absence of VT regularity during AFl (1 episode).(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗