Ascorbic and dehydroascorbic acid measurement in human serum and plasma.

Plasma supplemented with ascorbic acid was prepared; the stability of these samples was characterized and the accuracy of the supplementation was established. Studies on the accuracy, precision, and sources of methodological bias in the measurement of ascorbic acid were summarized. Measurements of the ratio of ascorbic acid to dehydroascorbic acid in clinical samples was evaluated and was shown to be relatively constant in plasma taken from blood stored at 12 degrees C for 6 h. These results imply that whole blood has the capacity to maintain a constant ascorbic-dehydroascorbic acid ratio and suggest that this ratio may be of physiological significance.

Ascorbic Acid

Ascorbic and dehydroascorbic acids measured in plasma preserved with dithiothreitol or metaphosphoric acid.

We describe a rapid method for accurately and precisely measuring ascorbic acid and dehydroascorbic acid in plasma. Total analysis time is less than 10 min, replicate analyses of a single pool provide precision less than or equal to 2%, and values measured in supplemented samples agree with known concentrations of 4.68 and 11.83 mg/L. The stability and homogeneity of lyophilized plasma samples supplemented with ascorbic acid and dithiothreitol are documented. We also describe a procedure in which metaphosphoric acid (50 g/L) is used to prepare a reference material for the measurement of ascorbic acid and dehydroascorbic acid. The procedure for both acids consists of first measuring the native ascorbic acid, then reducing the dehydroascorbic acid, at neutral pH, with dithiothreitol, and finally measuring the total ascorbic acid; dehydroascorbic acid is then determined by difference. The metaphosphoric-acid-treated samples were stable at -70 degrees C, but stability decreased with temperature over the range examined, 4-50 degrees C.

Ascorbic Acid

Chromatographic separations of serum proteins on immobilized metal ion stationary phases.

The separation of proteins on stationary phases consisting of a bound organic chelator and a chelated divalent transition metal has been studied as a function of (A) metal ion species; (B) mobile phase composition and pH; and (C) anion and cation concentration. Optimum separation was observed at alkaline pH on chelated nickel stationary phases. Ammonium and Tris salts reduced the affinity of the metal chelate packing for serum proteins. Halide ions caused the proteins to be more strongly bound to the stationary phase. High salt concentrations had only a small effect on the binding of serum proteins in the absence of amine containing buffers or salts. It was also observed that the ease of elution and the recovery of protein were dependent on pH and upon the presence of halides. The general order of elution of serum proteins, based on isoelectric focusing, was independent of metal ion species and elution conditions, suggesting that a single mechanism or a unique sequence of mechanisms was operative. The results suggest that ligand exchange is the major mechanism of separation under basic conditions and that hydrophobic effects are the result of the competition of nonnitrogen ions with ammonium ions or amines for ligand binding sites modifying or participating in protein binding. Protein binding studies under weak acidic conditions are also presented although the mechanism responsible for protein binding is unclear.

Blood Protein Electrophoresis

Structure of a hydroxyl radical induced DNA-protein cross-link involving thymine and tyrosine in nucleohistone.

Hydroxyl radical induced formation of a DNA-protein cross-link involving thymine and tyrosine in nucleohistone is described. Hydroxyl radicals were generated in N2O-saturated aqueous solution by ionizing radiation. Samples of nucleohistone were hydrolyzed with HCl and trimethylsilylated. Analysis of irradiated samples by gas chromatography-mass spectrometry with selected-ion monitoring showed the presence of a thymine-tyrosine cross-link on the basis of typical fragment ions from the previously known mass spectrum of its trimethylsilyl derivative. The yield of this DNA-protein cross-link in nucleohistone was measured at incrementing doses of radiation and found to be a linear function of radiation dose between 14 and 300 Gy (J.kg-1). This yield amounted to 0.003 mumol.J-1. The mechanism of formation of this DNA-protein cross-link is thought to result from H atom abstraction by hydroxyl radicals from the methyl group of thymine followed by the addition of the resultant thymine radical to the carbon 3 position of the tyrosine ring and subsequent oxidation of the adduct radical.

Animals

Structure of a hydroxyl radical induced cross-link of thymine and tyrosine.

DNA-protein cross-links are formed when living cells or isolated chromatin is exposed to ionizing radiation. Little is known about the actual cross-linked products of DNA and proteins. In this work, a novel hydroxyl radical induced cross-link of thymine and tyrosine has been isolated along with a tyrosine dimer by high-performance liquid chromatography of aqueous mixtures of tyrosine and thymine that had been exposed to hydroxyl radicals generated by ionizing radiation. The isolated compounds have been examined by gas chromatography-mass spectrometry, high-resolution mass spectrometry, and 1H and 13C nuclear magnetic resonance spectroscopy. The structure of the thymine-tyrosine cross-link has been identified as the product from the formation of a covalent bond between the methyl group of the thymine and carbon 3 of the tyrosine ring. In addition, the 3,3' tyrosine dimer was isolated and characterized. The mechanism of the formation of these compounds is discussed. This work presents the first complete chemical characterization of a hydroxyl radical induced DNA base-amino acid cross-link.

Chromatography, High Pressure Liquid

Stabilization of ascorbic acid in human plasma, and its liquid-chromatographic measurement.

We describe two independent HPLC procedures for the rapid, accurate analysis for ascorbic acid in human plasma. No sample extraction or phase separation is required. We also describe a procedure for preparing a human plasma reference material for use in clinical laboratory analysis for ascorbic acid. The ascorbic acid in plasma can be determined in 15 min, with as little as 50 microL of sample. Analytical recoveries are near 100% with direct injection of deproteinized plasma. Extensive stability data under several conditions, with dithiothreitol as a preservative (antioxidant), indicate that ascorbic acid remains stable in stored plasma for as long as 57 weeks. CVs for round-robin analysis of 11 normal human blood samples by two independent methods were between 0.1% and 5.3%. These clinical samples appear to be stable for at least 50 days under the described conditions of stabilization and sample treatment. Finally, because ascorbic acid prepared by the described procedures is stable at room temperature for at least 18 h, these methods can be readily adapted to clinical laboratory automation at room temperature.

Ascorbic Acid

Microprocessor-based weight shift monitors for paraplegic patients.

The prevention of pressure sores for patients with spinal cord injuries includes pressure relief through the patient shifting position and, thus, weight. We have designed a microprocessor-based device to mount on the seat of a conventional wheelchair. This device has applications in hospital rehabilitation programs for improving patient care and in research to study the cause and prevention of pressure sores. It can use audible alarms, which can be disarmed, to train patients to regularly shift weight. The device stores in its memory data on the interval between and the duration of weight shifts. The contents of this memory can be transmitted to a laboratory microcomputer system and displayed in tabular, graphical, or histogram formats. This device is more versatile than previous timer-based systems, not only because its timer and alarm parameters easily can be reprogrammed, but especially because it can store and play back detailed data on the patient's performance. The device is powered by rechargeable NiCad batteries, which can last several days without recharging.

Body Weight

Lactate dehydrogenase inhibitors in NADH preparations.

The presence of a new lactate dehydrogenase inhibitor on the trailing edge of the NADH peak from chromatography on diethylaminoethyl-celluose [Loshon et al., Clin. Chem., this issue] was verified. It was resolved from the NADH by high-performance liquid chromatography on muBondapak C18. When the new inhibitor was present in a reaction mixture to the extent that, of the initial 260-nm absorbance, about 5% was contributed by the inhibitor, the rate of NADH oxidation by lactate dehydrogenase decreased by 65%. The inhibitor absorbs at 260 and 340 nm, and is different from the Strandjord-Clayson inhibitor [J. Lab. Clin. Med. 67, 144 (1966)] by both types of chromatography. Because this new inhibitor has ultraviolet properties similar to those of NADH and chromatographs with the NADH on DEAE-cellulose, the high-performance liquid chromatographic method must be used to ensure its absence in preparations of NADH used for clinical assay.

Chromatography, DEAE-Cellulose

Purification and analysis of the purity of NADH.

We developed an analytical reverse-phase high-performance liquid chromatographic procedure for rapid assessment of the purity of NADH. The method completely separates adenosine monophosphate and adenosine diphosphoribose from NADH. By use of this analytical technique we found that preparative chromatography on DEAE-cellulose gives NADH that is free from adenine nucleotides as well as other impurities that commonly are present in NADH. The absorbance ratio at 260 and 340 nm of the purified NADH in 1.8 mmol/liter ammonium carbonate is 2.261 +/- 0.002 (+/- 1 SD).

Bicarbonates

Stabilization of ascorbic acid and its measurement by liquid chromatography in nonfat dry milk.

The determination of ascorbic acid by liquid chromatography (LC) was improved by performing the analysis in the presence of solvents that had been purged with argon to reduce the concentration of oxygen. This methodological modification eliminated the oxidation of ascorbic acid during the chromatographic procedure and reduced the minimum detection level to 1 microgram. Solutions of ascorbic acid have been successfully stabilized for 67 days by addition of dithiothreitol to a deaerated solution of water-acetonitrile (25 + 75 v/v), sealed under argon in amber vials and stored at -20 degrees C. In a second independent study, a procedure for the extraction of ascorbic acid from nonfat dry milk in a single step was developed. The ascorbic acid content of Nonfat Dry Milk (SRM 1549) was determined by LC, using the method of standard additions. The mean ascorbic acid content was 54 +/- 5 micrograms/g of sample. Analysis of variance of the analytical results indicates that there is a significant continual increase in the content of the ascorbic acid in each bottle from first to last sample.

Animals