PubMed Health⌕ Search

Biomedical subjects

S A Olson

Publications and source records attributed to S A Olson.

At least 19 recordsLinked to original sources

Comparison of antibiotic beads and intravenous antibiotics in open fractures.

This study compared the efficacy of antibiotic impregnated beads with conventional intravenous antibiotics in the treatment of open fractures. A randomized prospective study was designed and conducted during a 29-month period. Sixty-seven patients with 75 open fractures were treated similarly, with the exception of the method of antibiotic administration, and were followed up for at least 1 year after injury. Infection occurred in two of 24 (8.3%) fractures treated with antibiotic beads alone and in two of 38 (5.3%) fractures treated with conventional intravenous antibiotics. In an unanticipated nonrandomized third cohort group, patients received antibiotic beads and intravenous antibiotics administered for nonorthopaedic reasons or limb threatening injury, or both. Two of 13 (15.4%) fractures in this high risk group became infected. Infection ultimately resolved in all fractures treated with antibiotic beads alone or antibiotic beads in conjunction with conventional intravenous antibiotics. This study was unable to achieve statistical significance; however, the data suggest antibiotic beads may be useful in preventing infection in open fractures. Thus, a larger multicenter randomized prospective study of isolated open fractures, eliminating other variables, is justified.

Administration, Topical↗

Superior gluteal artery in the extended iliofemoral approach.

OBJECTIVE: To determine the incidence of superior gluteal artery injury following fracture of the acetabulum and to determine whether the combination of a superior gluteal artery injury and the use of an extended iliofemoral approach to the acetabulum creates abductor muscle necrosis. DESIGN: Prospective protocol, consecutive cases. SETTING: A consecutive series from the referral practice of the senior author plus seven cases from the practices of two other authors. PATIENTS: Two hundred twenty-seven patients with fractures of the acetabulum were treated operatively between November 1992 and January 1995. Forty-one were treated with the use of the extended iliofemoral approach. Preoperative angiograms were not performed for any of the patients. All fractures involved the posterior column, and all but two fractures had displacement of the greater sciatic notch. The average displacement of the notch was 2.5 centimeters (range 6 to 60 millimeters). INTERVENTION: All patients were treated with open reduction and internal fixation via the extended iliofemoral approach. Intraoperative Doppler examination of the superior gluteal artery was performed before and after reduction and fixation of the posterior column. MAIN OUTCOME MEASURE: Wound complications, abductor manual muscle testing, hip range of motion. RESULTS: Pulsatile flow was confirmed in forty of forty-one patients. All patients were followed for a minimum of six months with an average follow-up of 1.4 years. At most recent follow-up, no patients had evidence of complete loss of abductor function. Sixty-three percent of patients had achieved Grade 4 of 5 motor strength, and 25 percent of them had achieved normal motor strength. CONCLUSIONS: No instances of superior gluteal artery laceration and only one instance of superior gluteal artery thrombosis were encountered in these forty-one patients despite significant fracture displacement involving the sciatic notch. The incidence of superior gluteal artery injury was significantly less than would be expected from previous studies. Massive abductor necrosis resulting from superior gluteal artery injury combined with an extended approach has been described primarily in animal and cadaver studies. Although arteriograms are useful in the control of hemodynamic instability, we cannot support the recommendation of preoperative angiographic study of all patients undergoing acetabular fracture surgery via an extended approach. In one case, an extended iliofemoral approach was tolerated in a patient with absent superior gluteal artery flow.

Acetabulum↗

Acetabular fracture.

A twenty-eight-year-old female bicyclist was struck by a car. Associated injuries after trauma work-up included a splenic laceration that is to be treated with observation and a history of loss of consciousness with a negative head CT. X-rays and representative CT scan cuts are enclosed.

Accidents, Traffic↗

Factors related to hip muscle weakness following fixation of acetabular fractures.

Two hundred twenty-five acetabular fractures treated surgically by one surgeon using a single surgical approach were reviewed to identify the incidence of clinically significant hip muscle weakness. Clinical grade of fair or poor and presence of radiographic signs of osteoarthritis were most strongly correlated with hip muscle weakness (P<.0001). Other factors related to muscle weakness were >21 days to repair, abdominal trauma, infection, avascular necrosis, heterotopic ossification resection, chest trauma, and head trauma. The presence of arthritis at follow-up increased the incidence of hip muscle weakness (46% [41/89]; P<.0001) independent of surgical approach.

Acetabulum↗

Biomechanical evaluation of impaction fractures of the femoral head.

OBJECTIVES: To measure the effect of an impaction fracture of the femoral head on load transmission in the hip joint. DESIGN: We measured the contact areas and pressure between the acetabulum and femoral head of cadaveric pelves in four different conditions: intact, with an operatively created one-square-centimeter defect in the superior femoral head, with a two-square-centimeter defect, and with a four-square-centimeter defect. All defects were uniformly three millimeters deep. SETTING: Hips were loaded in a simulated single-limb stance. Pressure and area measurements were made with Fuji pressure-sensitive film. SPECIMENS: Seven hip joints in seven whole pelves were tested. MAIN OUTCOME MEASUREMENTS: Contact area, load, and mean and maximum pressures were measured. RESULTS: Peripheral loading was seen in the intact acetabulum. This was not disrupted after impaction fractures of any size. A significant increase in mean maximum pressures in the superior acetabulum was seen with two-square-centimeter and four-square-centimeter defects. CONCLUSIONS: In contrast to prior biomechanical studies of acetabular fractures, our investigation revealed that disruption of the peripheral distribution of load does not occur with impaction fractures of the femoral head. Clinical series indicate that impaction injuries to the femoral head are associated with a poor prognosis. Previous biomechanical data on acetabular fracture patterns associated with a poor prognosis have shown increases in mean and peak pressures in the superior acetabulum. This was seen with two-square-centimeter and four-square-centimeter impaction injuries. Other factors, such as wear of the articular cartilage during joint motion or associated microscopic damage to the remainder of the joint surface at the time of injury, may also contribute to the rapid joint deterioration seen in these injuries. Further study is indicated.

Acetabulum↗

Consequences of transverse acetabular fracture malreduction on load transmission across the hip joint.

OBJECTIVE: To evaluate the biomechanical behavior of gap and step malreductions in a model of transverse acetabular fracture. DESIGN: Cadaver pelvis loading in simulated single-leg stance with intact acetabulum, after transverse acetabular fracture anatomically reduced, and after step and gap malreduction. Five transtectal transverse fractures; five juxtatectal transverse fractures. SETTING: Quasi-static loading of the hip with simulated abductor mechanism to physiologic loads with pressure-sensitive film interposed in the joint to determine contact area and contact pressure within the hip joint. MAIN OUTCOME MEASUREMENT: Hip joint contact parameters: contact area, peak and mean contact pressure, and load distribution. RESULTS: Step malreduction of the transtectal transverse fracture resulted in significantly increased peak contact pressures (20.5 megapascals) in the superior acetabular articular surface as opposed to the intact acetabulum (9.1 megapascals). Gap malreduction of transtectal transverse fracture and step and gap malreduction of juxtatectal fracture did not result in significantly increased contact pressures in the hip. CONCLUSION: Step malreduction of a transverse acetabular fracture in the superior articular surface results in abnormally high contact forces and may predispose to the development of posttraumatic arthritis.

Acetabulum↗

Posttraumatic lymphocyte response: a comparison between peripheral blood T cells and tissue T cells.

BACKGROUND: T-cell response to trauma has been assessed primarily by sampling peripheral blood lymphocytes. We hypothesized that lymphocytes residing in tissue and traveling through lymph vessels are more likely to be activated by tissue injury and hemorrhage-induced hypoperfusion. We compared peripheral blood T-cell response with tissue or lymph T-cell response in an ovine model of multiple injury. METHODS: Anesthetized adult sheep instrumented with a chronic prefemoral lymph fistula were subjected to lower-extremity fractures, fixed-volume hemorrhage, resuscitation, and fracture stabilization. Peripheral blood and tissue T-cell receptor expression was determined at baseline and after injury. RESULTS: At baseline, we found significant differences in the expression of CD4, CD8, and L selectin between peripheral blood T cells and tissue T cells. After trauma, the percentage of tissue T cells expressing CD8 decreased from 19 +/- 9 to 14 +/- 5 (p < 0.05) and the percentage expressing gammadelta-TcR receptors decreased from 12 +/- 4 to 7 +/- 2 (p < 0.05). T-cell phenotype composition in peripheral blood was not affected by trauma. CONCLUSION: Peripheral blood T-cell composition differs from tissue T-cell composition before and after trauma. Trauma produced changes in tissue T-cell phenotypes but not in peripheral blood T-cell phenotypes.

Animals↗

The role of the acetabular labrum and the transverse acetabular ligament in load transmission in the hip.

We performed a biomechanical study of seventeen hip joints in the pelves of nine cadavera in order to assess the role that the acetabular labrum and the transverse acetabular ligament play in load transmission. The distribution of contact area and pressure between the acetabulum and the femoral head was measured with the hip in four different conditions: intact (seventeen hips), after removal of the transverse acetabular ligament (eight hips), after removal of the entire labrum (nine hips), and after removal of both the transverse acetabular ligament and the labrum (seventeen hips). The hip joint was loaded in simulated single-limb stance, and the measurements were made with use of pressure-sensitive film. A peripheral distribution of load was seen in the intact acetabula. This pattern was altered only minimally after removal of the transverse acetabular ligament or the labrum, or both. When both of these structures were removed, the only significant change was a decrease in the maximum pressure in the posterior aspect of the acetabulum (p = 0.02). No significant changes were detected with regard to the contact area, load, mean pressure, or maximum pressure in the anterior or superior aspect of the acetabulum under any testing condition.

Acetabulum↗

Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains.

The hip is a common site of orthopaedic trauma and disease, and considerable research has been directed toward understanding the development of contact pressures within the joint. Virtually all experimental studies to date have employed proximal femurs compressed along the joint reaction force vector into acetabulae explanted from cadaver pelves. This approach presumes that deformations of the acetabulum are highly localized, and that the pelvis is functionally a rigid body. We have developed a methodology that uses intact pelves loaded through simulation of the abductor mechanism. A direct comparison of the two techniques revealed significantly different joint contact characteristics and periacetabular strains. Fuji film measurements of contact area and pressure were more widely distributed across the acetabulum for the intact pelvis, with significant pressure development in anterior and posterior regions. Contact patterns in the explanted acetabulae were concentrated in the superior portion of the joint. Principal strains from three rosette gages placed near the acetabular rim were also significantly different for the two testing techniques, but were not substantially altered by the presence of Fuji film within the joint. The results indicate that deformation of the entire pelvis and the manner in which loads are applied significantly affect development of contact pressures within the hip joint, and that Fuji film is a suitable technique for recording those patterns.

Acetabulum↗

Reamed femoral nailing in patients with multiple injuries. Adverse effects of tourniquet use.

Limb reperfusion after tourniquet ischemia causes pulmonary microvascular injury. Similarly, microembolization, like that associated with reamed femoral nailing, can induce pulmonary microvascular injury. Both processes result in increased pulmonary capillary membrane permeability and edema. However, the association between femoral nailing followed by tourniquet ischemia and clinical lung injury has not been described. The authors reviewed 72 patients with femoral shaft fractures and tibial or ankle fractures requiring internal fixation between 1987 and 1993. All femoral shaft fractures were treated with reamed intramedullary nails. Patients were divided into groups, based on whether the tibial or ankle injury was managed surgically with (Group T, 34 patients) or without (Group NT, 38 patients) a tourniquet. Group T was subdivided based on tourniquet time: T1, less than or equal to 90 minutes; T2, greater than 90 minutes. Groups were matched for injury severity. Group NT had fewer ventilator dependent days and intensive care days than Group T (NT: ventilator dependent days, 2.5 +/- 5.2; intensive care days, 3.9 +/- 6.5; T: 5.1 +/- 6.4; intensive care days, 6.7 +/- 6.6). Ventilator dependent days and intensive care days increased with increasing tourniquet time (T1: ventilator dependent days, 3.2 +/- 3.6; intensive care days, 5.4 +/- 4.6; T2: ventilator dependent days, 7.5 +/- 8.5; intensive care days, 8.5 +/- 8.5), suggesting that in patients with multitrauma, combining reamed femoral nailing with fracture fixation under tourniquet control increases pulmonary morbidity. Further investigation to measure pulmonary injury associated with ischemia reperfusion and intramedullary nailing in patients with multitrauma is warranted.

Adult↗

Nonreamed locking intramedullary nailing for open fractures of the tibia.

The use of nonreamed interlocking tibial nails in the management of open fractures of the tibial shaft has gained wide acceptance. This technique has been reported to have reproducible good results with a low incidence of complications in Type I, Type II, and Type IIIA open tibial shaft fractures. The use of nonreamed nails in Type IIIB fractures continues to be a source of controversy. The treatment of 72 open fractures of the tibial shaft with nonreamed interlocking intramedullary nailing is detailed. There were 27 Type I, 22 Type II, 11 Type IIIA, and 12 Type IIIB open tibial shaft fractures. There were three (4.2%) deep infections; one Type II, one Type IIIA, and one Type IIIB. Forty-nine fractures (68%) united by 6 months, all fractures had united by 12 months. The use of nonreamed locking intramedullary nailing in Types I, II, IIIA, and IIIB open fractures of the tibial shaft is supported.

Adolescent↗

Biomechanics of the hip joint and the effects of fracture of the acetabulum.

The biomechanical analysis of the normal and arthritic hip joint have been the subject of numerous publications in orthopaedics. Biomechanical investigations focusing on the effect of fractures of the acetabulum on the alteration of hip joint mechanics have been a recent development. This paper outlines currently available methodologies for simulating load across the hip, and as measuring articular contact and contact stresses. Results of investigations of posterior wall fractures and transverse fractures of the acetabulum are presented. Directions for future research in the area of mechanical investigations of acetabular fractures are discussed.

Acetabulum↗

Diagnosis and management of closed internal degloving injuries associated with pelvic and acetabular fractures: the Morel-Lavallée lesion.

Closed internal degloving is a significant soft-tissue injury associated with a pelvic trauma in which the subcutaneous tissue is torn away from the underlying fascia, creating a cavity filled with hematoma and liquefied fat. It commonly occurs over the greater trochanter but may also occur in the flank and lumbodorsal region. When this closed internal degloving occurs over the greater trochanter, it is known as a Morel-Lavallée lesion. We reviewed 24 patients who sustained a closed internal degloving injury. Cultures from the closed internal degloving injury were positive in 46% (11 of 24 cases). The incidence of positive cultures was not dependent on the time from injury to debridement. All wounds were treated by thorough debridement before or during pelvic or acetabular surgery. Three patients subsequently developed deep-bone infections, only one of whom had a positive culture at the initial debridement. One patient whose wound was primarily closed over suction drains developed a chronic deep soft-tissue infection requiring multiple debridements. The development of hematoma in the zone of operation reduces the safety of early operative intervention by increasing the risk of infection. An expanding hematoma in a closed internal degloving injury may further compromise the skin vascularity if not promptly drained. The injured soft tissues should be debrided early, either before or at the time of fracture fixation. The wound should be left open, and repeated surgical debridement of the injured tissue is recommended.

Acetabulum↗

Amputation versus limb salvage.

The decision to attempt salvage or to amputate a severely injured leg in among the most difficult that the orthopaedist must face. Even surgeons with tremendous trauma experience cannot agree on standard course of action. In the face of such injuries, physician consultation regarding the treatment decision, including all of those members of the team that are needed for a successful salvage, is necessary. In the best circumstances, the trauma surgeon, vascular surgeon, orthopaedist, and a soft-tissue specialist are all involved. From a psychological perspective, the timing of an amputation is important. Although each patient's case is unique, immediate amputation is often viewed by the patient and family as a result of the injury. Conversely, a delayed amputation may be viewed as a failure of treatment. It is imperative that the surgeon have a detailed discussion with the patient and the family whenever possible before making the decisions. Scoring systems are of some help in estimating the chances of a successful salvage. However, the ultimate decision to amputate or attempt salvage is based on such patient factors as preinjury function and social situation, and of associated injuries, surgeon experience, available resources, projected physical abilities, and the patient's projected physical requirements. These decisions are difficult and tax the judgment and emotions of the patient, family, and physician.

Adult↗

Assessment of pelvic ring stability after injury. Indications for surgical stabilization.

The indications for surgical stabilization of pelvic ring injuries are based on an assessment of the extent of disruption of the pelvic ring and the associated deformity of the bony pelvis. The relevant anatomy and biomechanics or the pelvis, pelvic ring injury classifications, initial assessment, and emergent treatment of patients with pelvic ring injuries is reviewed, and a discussion or indications for surgical stabilization of pelvic ring disruptions is presented.

Biomechanical Phenomena↗

The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0.0001) and 1/3 width defect (p = 0.0222). The total absolute contact areas for all defect conditions were significantly less than the intact conditions. The results of this study reconfirm the observation that posterior wall fractures of the acetabulum significantly alter the articular contact characteristics in the hip during single leg stance. The relationship between defect size and changes in joint contact showed that the smallest defect resulted in the greatest alteration in joint contact areas, whereas larger defects resulted in minor increments of change in contact area. This finding is of concern because the clinical practice of managing acetabular fractures nonoperatively if the hip joint is stable is based on the supposition that the joint retains enough integrity to function without undue risk of late posttraumatic osteoarthritis. A better understanding of the natural history of stable posterior wall acetabular fractures is needed to ascertain whether some of these fractures merit operative repair.

Acetabulum↗

Removal of intramedullary nails from the femur: a review of 45 cases.

The excellent biocompatibility of titanium and its alloys may result in osseointegration. In order to determine if this presents an obstacle to removal of intramedullary nails, we retrospectively reviewed a series of 45 cases of isolated removal of a femoral nail. Indications for removal were persistent pain and discomfort, request of an asymptomatic patient, or skeletal immaturity. Twenty-three nails were titanium, and 22 were stainless steel. Although removal of the titanium nails had a significantly longer operative time (110 vs. 84 min), analysis of variance indicated that this was due to a greater number of crosslocking screws in the titanium nails (2.2 vs. 0.6) and a tendency to set the titanium nails deeper in the femur. The use of the titanium material per se did not pose a risk factor for difficulty in late removal of an intramedullary nail.

Adult↗