Electrokinetic chromatography of twelve monomethylbenz[a]anthracene isomers using a polymerized anionic surfactant.

A method for the separation of twelve monomethyl-substituted benz[a]anthracene isomers using poly-(sodium undecylenic sulfate) (poly-SUS) surfactant by means of electrokinetic capillary chromatography (EKC) is described. Several parameters such as concentration of acetonitrile (ACN), pH, as well as applied voltage were studied to optimize the EKC separation. ACN at a concentration of 35% v/v, 12.5 mM phosphate-borate buffer, 30 kV with 0.5% w/v poly-SUS at a pH of 9.5 provided a resolution of a mixture of nine out of twelve methylbenz[a]anthracene (MBA) isomers in 50 min. The results of this study suggest that molecular length of MBA rather than length-to-breath ratio plays an important role in the elution order of some isomers.

Acetonitriles

Cationic beta-cyclodextrin derivative for chiral separations.

A novel hepta-substituted beta-cyclodextrin bearing the methoxyethylamine group linked to the upper cyclodextrin rim was successfully used as a chiral selector for enantiomeric separation of non-steroidal anti-inflammatory drugs (NSAIDs) and phenoxypropionic acid herbicides (PPAHs). Separation parameters such as pH and concentration were found to have major influences on enantiomeric resolution of the NSAIDs and PPAHs. Results indicate that heptakis(6-methoxyethylamine-6-deoxy)-beta-cyclodextrin [beta-CD-OMe (VII)] performs exceptionally well for the enantiomeric resolution of NSAIDs: indoprofen and fenoprofen (Rs = 11 and 14, respectively). In addition, baseline enantiomeric separation of a mixture of six pairs of PPAHs was achieved in under 30 min. Compared to other cationic beta-cyclodextrins reported in the literature, the beta-CD-OMe (VII) showed improved selectivity for both classes of the aforementioned anionic racemates.

Anti-Inflammatory Agents, Non-Steroidal

Capillary zone electrophoresis of bile acids with indirect photometric detection.

Investigations in our laboratory have demonstrated that capillary zone electrophoresis (CZE) with indirect photometric detection is a viable approach to the separation and identification of free bile acids along with their taurine and glycine derivatives. Various parameters such as pH, organic solvent concentrations, column temperature, and type of chromophore electrolyte were investigated to optimize the electrophoretic separation and to maximize the peak capacity. The quality of separation of bile acids can be dramatically improved by incorporating gamma-cyclodextrin (gamma-CD) in the running electrolyte. This improvement in resolution is accompanied by a decreased migration time, suggestive of an increase in association of gamma-CD with bile acids. As a result, a CZE separation of all 15 bile acids was possible in approximately 30 min using 5 mM adenosine 5'-monophosphate, 7 mM gamma-CD in 75% (v/v) methanol at pH 7.0.

Adenosine Monophosphate

Chiral separations using dipeptide polymerized surfactants: effect of amino acid order.

Chiral separations using various polymerized dipeptide surfactants in electrokinetic capillary chromatography (EKC) are investigated. The two main dipeptide surfactants used in this study were sodium N-undecylenyl-L-valine-L-leucine (L-SUVL), and sodium N-undecylenyl-L-leucine-L-valine (L-SULV). These studies were performed in order to determine if the order of amino acids in dipeptide surfactants is important in terms of chiral recognition and separations. Both the monomer and the polymer of these two surfactants were compared for the separation of two model atropisomers, (+/-)-1,1-bi-2-naphtol (BOH) and (+/-)-1,1'-bi-2-naphthyl-2,2'-diyl hydrogen phosphate (BNP). Some advantages and disadvantages of the polymer relative to the monomer are discussed. Four other surfactants, the polymers of sodium N-undecylenyl-L-leucine-L-leucine (L-SULL), sodium N-undecylenyl-L-valine-L-valine (L-SUVV), sodium N-undecylenyl-L-valine (L-SUV), and sodium N-undecylenyl-L-leucine (L-SUL), were also used in this study, and their performance was compared to that of poly(L-SULV). These data show conclusively that the order of amino acids in dipeptide surfactants has a dramatic effect on chiral recognition. Our investigations indicate that poly-(L-SULV) provides the best enantioselectivity among the four dipeptide and two single amino acid surfactants for the separation of BNP and BOH. The advantages of poly-(L-SULV) are demonstrated via the ultrafast separation of the enantiomers of BNP and BOH in less than 1 min.

Amino Acids

Enhanced separation of antidepressant drugs using a polymerized nonionic surfactant as a transient capillary coating.

The separation of seven structurally similar antidepressant drugs (amitriptyline, nortriptyline, imipramine, desipramine, protriptyline, doxepin, and nordoxepin) was achieved in under 15 min using a novel nonionic micelle polymer, poly(n-undecyl-alpha-D-glucopyranoside) (PUG) by use of capillary zone electrophoresis (CZE). Systematic studies with varying polymer concentration, pH, and percent organic modifier were conducted in order to find the optimum conditions for baseline separation of the seven tricyclic antidepressants. In addition, equations for capacity factor were used to estimate the extent of what was initially thought to be micelle analyte interaction. A series of calculations show that a modified CZE system (PUG-CZE) was the actual mode of separation. Thus, our study concluded that PUG functioned in a non-electrokinetic chromatography mode.

Antidepressive Agents

On-line capillary electrophoresis-electrospray ionization mass spectrometry using a polymerized anionic surfactant.

On-line capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) has been used to determine the tricyclic antidepressant drugs (imipramine, doxepin, and amitriptyline) as well as the beta-adrenergic blocker drugs (propranolol and alprenolol). A CE-ESI-MS interface linking a manually operated CE system and a Finnigan MAT-900 sector mass spectrometer (with an Analytica electrospray ionization source) has been constructed in-house and employed for this study. Although a water/methanol based capillary zone electrophoresis (CZE) buffer was initially used to determine these analytes, enhanced resolution was obtained by addition of a polymerized surfactant, i.e., poly-sodium undecylenic sulfate (poly-SUS), into the electrokinetic chromatography (EKC) buffer. When a low concentration of this poly-SUS surfactant was added to a volatile EKC buffer, these structurally similar cationic drugs were EKC separated and on-line detected by ESI-MS.

Adrenergic beta-Antagonists

Capillary electrophoresis of phospholipids with indirect photometric detection.

The capillary electrophoresis (CE) separation of different anionic phospholipid classes including phosphatidic acids (PA), phosphatidylserine, phosphatidylinositol, phosphatidylglycerol (PG), and cardiolipin using indirect detection with adenosine monophosphate (AMP) is described. A standard mixture of PAs (C14, C16, and C18) can be separated in 10 min by CE using 5 mM AMP and 100 mM boric acid in 10% water--80% methanol--10% acetonitrile. Although nonionic surfactants such as Brij 35 can improve the CE resolution of PAs, the separation time and the baseline noise are both increased. Optimization of the organic solvent in the running electrolyte is important. Methanol provides faster electroosmotic flow than propanol, and 10% acetonitrile effectively reduces migration time further by a factor of 1.4-2.2, depending on the phospholipid. The concentration limit of detection ranges from approximately 2 to 6 mg/L, and the mass limit of detection is as low as 21 pg. Linearity from 19 to 100 mg/L is established for cardiolipin and C16-PG. Phospholipids in soybean and brain extract samples could be profiled.

1-Propanol

A persubstituted cationic beta-cyclodextrin for chiral separations.

The applications of a novel polycationic derivative of beta-cyclodextrin (beta-CD), heptakis(6-hydroxyethylamino-6-deoxy-beta-cyclodextrin) (beta-CD-EA), as a chiral host--guest additive for the enantioseparation of various classes of chiral anionic analytes are presented. The cationic beta-CD described in this paper is persubstituted with seven ethanolamine side arms at the primary rim of each cyclodextrin (CD) molecule. It is found that the electrophoretic mobility of beta-CD-EA can be adjusted to influence the chiral selectivity by changing the pH of the background electrolyte. Most of the observed CD capillary zone electrophoresis (CZE) separations of anionic drugs and herbicides were accomplished in the pH range of 4.0-7.0 with a reverse polarity configuration. At pH 5.0, enantioseparation of a mixture of three structurally related antiinflammatory agents (fenoprofen, flurbiprofen, and ibuprofen) was possible in about 30 min. However, other chiral acids, such as a series of phenoxypropionic acid herbicides and dansylated amino acids (glutamic acid and aspartic acids), were best separated at pH 6.0 or 7.0. An impressive separation of a mixture of six structurally related anionic herbicides [(+/-)-2-phenoxypropionic acid, (+/-)-2-(2-chlorophenoxy)propionic acid, (+/-)-2-(3-chlorophenoxy)propionic acid, (+/-)-2-(4-chlorophenoxy)propionic acid, (+/-)-2-(2,4-dichlorophenoxy)propionic acid, and (+/-)-2-(2,4,5-trichlorophenoxy)propionic acid] was achieved for the first time in about 15 min during a single run with 20 mM beta-CD-EA. The analytical applicability of this cationic CD molecule for chiral separations is discussed in detail.

Amino Acids

Improved chiral separations using a polymerized dipeptide anionic chiral surfactant in electrokinetic chromatography: separations of basic, acidic, and neutral racemates.

Two polymeric chiral anionic surfactants [poly(sodium N-undecylenyl-L-valine) (poly-L-SUV) and poly(sodium N-undecylenyl-L-valine-valine) (poly-L-SUVV)] are compared as pseudostationary phases for chiral separations of basic, acidic, and neutral enantiomers. Parameters such as pH, concentration and type of background electrolyte, concentration of polymerized chiral surfactants, and injection size were studied to investigate the migration behavior and optimize the chiral resolution of several racemic analytes. At equivalent monomer concentrations, the migration factors for cationic enantiomers were larger with poly-L-SUV than with poly-L-SUVV. In contrast, the reverse was true for anionic enantiomers. However, in both cases, chiral recognition was significantly enhanced with poly-L-SUVV as compared to that with poly-L-SUV. It is interesting to note that the separation selectivity and resolution of a neutral racemate were slightly better with the latter, but only at the expense of longer analysis time and lower efficiencies.

Buffers

Studies of polymerized sodium N-undecylenyl-L-valinate in chiral micellar electrokinetic capillary chromatography of neutral, acidic, and basic compounds.

The polymerized surfactant poly(sodium N-undecylenyl amino L-valinate) [poly(L-SUV)] has been used in micellar electrokinetic capillary chromatography for the chiral separation of various acidic and basic drugs, as well as neutral compounds. Under the conditions studied, poly(L-SUV) was shown to be a very versatile anionic chiral selector in the pH range of 5.6-11. The micelle was used for the enantioseparation of coumarinic anticoagulant drugs with various buffers under moderately acidic conditions. Neutral and alkaline buffer conditions were used to successfully separate the neutral atropisomers (+/-)-1,1'-bi-2-naphthol, (+/-)-1,1'-binaphthyl-2,2'-diamine, and Tröger's base. Chiral separation of the cationic paveroline drugs, laudanosine, norlaudanosoline, and laudanosoline, was influenced by pH and the use of coated capillaries. The acquired data focused on optimizing the migration times, capacity and separation factors, and electrophoretic mobilities of the various racemic mixtures.

Chromatography

Phosphated surfactants as pseudostationary phase for micellar electrokinetic chromatography: separation of polycyclic aromatic hydrocarbons.

A double alkyl chain di(2-ethylhexyl)phosphate (DEHP) is introduced as a potential anionic micellar pseudophase for a wide range of benzene derivatives and/or polycyclic aromatic hydrocarbons (PAHs). Several parameters such as concentration of phosphated surfactant, type and concentration of organic solvents (acetonitrile, isopropanol, and methanol), as well as capillary electrophoresis separation voltage were optimized to enhance resolution, efficiency and selectivity as well as to maximize peak capacities. The migration times and selectivity order for a number of PAHs differ significantly, depending on the type of organic solvent added to the DEHP surfactant. Acetonitrile at a concentration of 30% v/v in combination with 100 mM DEHP gave optimum separation for a mixture of 21 benzene derivatives and PAHs in under 16 min.

Benzene Derivatives

Separation of phosphorylated sugars using capillary electrophoresis with indirect photometric detection.

Adenosine monophosphate (AMP) and naphthalene disulfonate (NDS) have been characterized as electrolytes for the indirect photometric detection of phosphorylated sugars and other organophosphorus compounds of biochemical interest. This work has resulted in the CE separation on an uncoated capillary using 5 mM AMP and 100 mM boric acid at pH 7.2 of six metabolites (glucose-6-phosphate [G6P], fructose-6-phosphate [F6P]), fructose-1,6-bisphosphate [F-1,6-P], dihydroxyacetone phosphate [DHAP], glyceraldehyde-3-phosphate [G3P], and 2-phosphoglycerate [2-PG] or 3-phosphoglycerate [3-PG]) found in the glycolytic pathway. The detection limits using a 5-sec injection time were between 0.5 and 1 mg/L for these compounds, with the exception of G3P. Resolution between 3-PG and 2-PG is possible by the addition of magnesium ion, although the separation time is longer. A successful separation of five monophosphorylated sugars (G6P, F6P, ribose-5-phosphate [R5P], sucrose-6-phosphate [S6P], and 2-PG) has been performed using the same conditions as for the glycolytic pathway separation. A separation of bisphosphorylated sugars (glucose-1,6-bisphosphate [G-1,6-P],F-1,6-P, ribulose-1,5-bisphosphate [Ru-1, 5P], and sedoheptulose-1,7-bisphosphate [S-1, 7P]) could not be performed with AMP unless magnesium chloride was added. With NDS, a separation of these bisphosphorylated sugars can be obtained without the addition of magnesium chloride.

Dihydroxyacetone Phosphate